KEMMERICH ELEKTROMOTOREN
- Rated output P2 [kW]: 0.55
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Specified speed [min−1]: 1400
- Rated current [A]: 4.00
- Starting torque / rated torque: 2.50
- Frame size: 80
- Number of poles: 4
- Degree of protection: IP55
- Insulation class: F
- Ambient temperature: ≤ +40 °C
- Installation altitude up to [m]: 1000
- Vibration grade: N
- Mounting arrangement: Variants as selected
- Shaft end D × E [mm]: 19 × 40
- With run and start capacitors
- Dynamically balanced with half key
- Shaft end including key
- Removable feet; rotatable terminal box
End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
with operating capacitor and starting capacitor Ma/Mn 2,50
Maximum rated power at maximum 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
- Colour: RAL7030
Pole-changing three-phase motor - Constant torque
| Motor frame size | 80K |
|---|---|
| Number of poles | 4/2 |
| Output power | 0.48/0.6 kW |
| Synchronous speed at 50 Hz | 1500/3000 min-1 |
| Application | Constant torque |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Δ/YY - Dahlander |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.
- Product type: three-phase asynchronous motor
- Rated power: 0,75 kW; 0,66 kW
- Speed: 0920 1/min; 1100 1/min
- Voltage: 230 V Δ / 400 V Y; 265 V Δ / 460 V Y
- Frequency: 50 Hz; 60 Hz
- Duty type: S1
- Efficiency class: IE2; IE3
- Torque: 8,00 Nm
- Standards: IEC 60034-1; IEC 60034-9
- Product type: three-phase asynchronous motor
- Rated power: 0,75 kW; 0,66 kW
- Speed: 0920 1/min; 1100 1/min
- Voltage: 230 V Δ / 400 V Y; 265 V Δ / 460 V Y
- Frequency: 50 Hz; 60 Hz
- Duty type: S1
- Efficiency class: IE2; IE3
- Torque: 8,00 Nm
- Standards: IEC 60034-1; IEC 60034-9
Pole-changing three-phase motor - Fan drive
| Motor frame size | 80K |
|---|---|
| Number of poles | 4/2 |
| Output power | 0.19/0.75 kW |
| Synchronous speed at 50 Hz | 1500/3000 min-1 |
| Application | Fan drive |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Y/YY - Dahlander |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.
Pole-changing three-phase motor - Constant torque
| Motor frame size | 80K |
|---|---|
| Number of poles | 8/4 |
| Output power | 0.18/0.3 kW |
| Synchronous speed at 50 Hz | 750/1500 min-1 |
| Application | Constant torque |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Δ/YY - Dahlander |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.
6-pole from melamine
Complete with loose accessories
Inverters can supply standard household appliances with electricity.
For this purpose, batteries which are dimensioned with 12 V, 24 V or 48 V DC are used.
The inverters are short-circuit-proof and protected against overheating (whether caused by overload or by ambient temperature).
High switched-on power. This is required for switching on loads such as voltage converters for LED lamps, halogen lamps or power tools. ECO mode: In ECO mode, the inverter switches to standby as soon as the load drops below a preset value (minimum load: 15W). In standby mode, the inverter then switches on for a short period of time (regulateable standard setting: every 2,5 seconds. If the load exceeds a preset threshold value, the inverter remains switched on. Remote-controlled on/off control: A remote-controlled on/off switch can be connected to a two-pole plug or between the positive pole of the battery and the left contact of the two-pole plug.
Fully configurable:
threshold values for triggering and resetting alarms in the case of low battery charge.
• Threshold values for switching off and restarting at low battery voltage values.
• Dynamic shutdown: Load-dependent cut-off threshold
• Output voltage 210 -245V
• Frequency 50 Hz or 60 Hz
• Threshold for ECO mode on/off and ECO mode sensor
Monitoring:
• Input and output voltage, % load and alarms
battery terminal screw terminals; Contrast Performance at 25°C: 375 VA; peak power 700 W; output AC voltage / frequency (regulable) 230 VAC or 120VAC +/-3% 50 Hz or 60 Hz +/-0,1%; input voltage range 9,2 -17 / 18,4 -34,0 / 36,8 -62,0 V; Detection battery charged (regulateable) 14,0 / 28,0 / 56,0V; Max. efficiency 90 / 90 / 91%; Zero load power 6 / 6,5 / 9W; Default zero load power in ECO mode (default re-test interval): 2,5 s, adjustable) 1 / 1,5 / 3,0W; Stop settings for ECO mode and start performance controllable; operating temperature range -40 to +65°C (fan ventilation) (reduction of the power 1,25% per °C above 25°C); humidity (non-condensing) max 95%; Material & Color Steel Case and Plastic Cover (BLUE RAL 5012); Maximum cross section of the cable 10 mm2 / AWG8; Standard AC outputs 230V Schuko (CEE 7/4), IEC-320 (plug supplied)
protection class IP 21; Dimensions (HxBxT, 86 x 165 x 260 mm)
Optional accessories:
VE.Direct Bluetooth Smart Dongle
- Battery alarm
BMV battery monitor
VictronConnect
With VictronConnect, you can request live status information and configure any Victron product that either has a built-in Bluetooth feature or is connected to a VE.Direct Bluetooth Smart Dongle.
Android
https://play.google.com/store/apps/details?id=com.victronenergy.victronconnect
Windows
http://updates.victronenergy.com/feeds/VictronConnect/windows/w7/VictronConnectInstaller.exe
Apple
https://itunes.apple.com/us/app/victron-connect/id943840744?mt=8
Mac
https://itunes.apple.com/us/app/victronconnect/id1084677271?ls=1&mt=12
- material: steel, galvanized surface
- with 4x motor mounting bolts M16x60 with nut
- with 2x tensioning screws
- with adjustable tensioning blocks
- anchoring to the industrial floor using foundation blocks according to DIN 799
- comprising 2x slide rails (2x = 1 Set)
- Rated output P2 [kW]: 0.75
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Rated speed [min−1]: 1340
- Rated current [A]: 5.6
- Rated torque [N·m]: 5.35
- Efficiency [%]: 65
- Power factor cos φ: 0.90
- Starting current / rated current: 2.5
- Starting torque / rated torque: 0.65
- Breakdown torque / rated torque: 1.5
- Moment of inertia J [kg·m²]: 0.00265
- Run capacitor [µF]: 25
- Frame size: 80
- Number of poles: 4
- Degree of protection: IP55
- Insulation class: F
- Motor weight, base design [kg]: 11.5
- Ambient temperature: -15…+40 °C
- Colour: RAL 5010
- Design standard: IEC 60034-1 / PN-EN 60034-1
- Mounting arrangement: Variants as selected
- Capacitor rated voltage [V]: 450
- Shaft end D × E [mm]: 19j6 × 40
- Bearings: 6204 2Z
- With run capacitor
- Further dimensions [mm]: D = 19j6; E = 40; F = 6h9; GA = 21.5; DW = M20; AC = 157; AD = 95; BL = 15; L = 306; LC = 357
- Foot dimensions [mm]: A = 125; B = 100; C = 50; CA = 120; H = 80 (−0.5); K = 10; K1 = 13; AA = 55; AB = 160; BB = 130; HA = 9; HD = 200
- Flange dimensions [mm] B5: R = 0; HB = 120; P = 200; M = 165; N = 130j6; S = 12; LA = 10; T = 3.5
- Flange dimensions [mm] B14A: R = 0; HB = 120; P = 120; M = 100; N = 80j6; S = M6; LE = 12; T = 3
- Flange dimensions [mm] B14B: R = 0; HB = 120; P = 160; M = 130; N = 110j6; S = M8; LE = 14; T = 3.5
End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
with operating capacitor nominal power at max 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
- Colour: RAL7030
Missing dimensions and version-specific dimensioned drawings on request.
Important compatibility information: This stator housing is suitable exclusively for the corresponding components in our Ductile cast iron housing series, in the matching frame size and version. It is not compatible with motors, housings or components from other manufacturers or product series. The same frame size alone does not guarantee a fit. Please have the exact match and connection dimensions checked before ordering.
Stator housing – ductile cast iron, IEC frame 90, LB3 terminal box on top.
Missing dimensions and version-specific dimensioned drawings on request.
Important compatibility information: This stator housing is suitable exclusively for the corresponding components in our Ductile cast iron housing series, in the matching frame size and version. It is not compatible with motors, housings or components from other manufacturers or product series. The same frame size alone does not guarantee a fit. Please have the exact match and connection dimensions checked before ordering.
Stator housing – ductile cast iron, IEC frame 90, LB3 terminal box at side.
Communication card
- Type: PNE001Z-2
- Compatible with: VFS15 / VFAS3
- Communication: PROFINET
The soft starter SAS [3 – 11 kW] is a compact, single-phase controlled soft starter for the safe and uniform running up of three-phase and pole-switchable motors. It reduces mechanical loads during start-up, extends the service life of the drives and can be used universally in 230 V- and 400 V networks. Thanks to its simple parameterization and integrated bridging relays, the SAS series is ideal for compact controls and retrofit applications.
Characteristics
- single-phase soft starter
- Suitable for pole-switchable motors
- Switching from 400 V- to 230 V networks
- terminal arrangement suitable for switching installations
- for snapping onto 35 mm standard rail
- Bridging relays integrated
- no network center conductor (N) required
- Special voltages up to 640 V on request
- also suitable for single-phase applications
- Degree of protection IP 20
Functions
- Soft start with adjustable ramp
- two separately adjustable parameters: Start-up torque and start-up time
- Control input for pole-switchable motors
Options (on request)
- Potential-free input for control voltage 10 – 30 V DC
- SAS 3 – SAS 11 can be used as standard up to 480 V
- Special voltages 500 – 640 V (100 mm housing)
Technical data (excerpt)
- Mains voltage: 160 – 240 V ± 10 % (X1–X2 bridged) or 380 – 480 V ± 10 % (X1–X2 open)
- Nominal equipment power: 6,5 A / 12 A / 15 A / 25 A
- Engine power: 3 – 11 kW at 400 V
- System frequency: 50/60 Hz
- Start-up torque: 0 – 50 %
- Start-up time: 0,5 – 5 s
- maximum switching frequency: up to 240 /h (depending on type)
- maximum connection cross section: 2,5 mm²
- Ambient temperature: 0 – 45 °C / Warehouse –25 – 75 °C
- Weight: 0,3 – 0,5 kg
Preferred areas of application
- Door and door drives
- Packaging machinery
- Transport equipment
- Transformer or single-phase soft start systems
- Universal small drive applications
Note:
When using IE3-Motoren, higher starting and braking currents must be taken into account. We recommend that soft starters and brake devices should generally be dimensioned to a higher power level.
Steel brake motor fan cover IEC 200, primed, with side mounting holes.
Inside diameter a = 382 mm; Depth b-h = 198 mm; Overall depth b = 200 mm.
Sheet thickness c = 1.5 mm; Mounting hole f = 6.8 mm.
Check diameter, depth and mounting dimensions against the motor before ordering.
Pole-changing three-phase motor
| Operating data | Standard application / 6 | Standard application / 4 |
|---|---|---|
| Number of poles | 6 | 4 |
| Rated output [kW] | 0.18 | 0.55 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | Y |
| Rated current [A] | 0.9 | 1.4 |
| Rated speed [min-1] | 970 | 1380 |
| Rated torque [N·m] | 1.77 | 3.81 |
| Efficiency at rated load [%] | 50 | 68 |
| Power factor cos φ | 0.5 | 0.8 |
| Starting current / rated current | 3.0 | 3.0 |
| Starting torque / rated torque | 2.0 | 1.4 |
| Breakdown torque / rated torque | 2.6 | 1.6 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 80 |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 8.6 |
| Moment of inertia [kg·m²] | 0.00207 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
- Colour: RAL7030
MP42.33 — Permanent magnet DC motor
Series overview. The operating points and mechanics of the selected article variant apply.
| Parameter | Value | Unit |
|---|---|---|
| Operating data · Operating point 1 (12 V DC) | ||
| Rated voltage | 12 | V DC |
| Output power | 30 | W |
| Speed | 3,000 | min⁻¹ |
| Rated current | 3.7 | A |
| Rated torque | 0.1 | Nm |
| Maximum torque | 0.4 | Nm |
| Duty type | S1 | |
| Maximum current | 15 | A |
| Armature resistance | 0.5 | Ω |
| Armature inductance | 1.5 | mH |
| Operating data · Operating point 2 (24 V DC) | ||
| Rated voltage | 24 | V DC |
| Output power | 15 | W |
| Speed | 1,500 | min⁻¹ |
| Rated current | On request | A |
| Rated torque | 0.095 (calculated) | Nm |
| Maximum torque | On request | Nm |
| Duty type | On request | |
| Maximum current | On request | A |
| Armature resistance | On request | Ω |
| Armature inductance | On request | mH |
| Operating data · Operating point 3 (24 V DC) | ||
| Rated voltage | 24 | V DC |
| Output power | 30 | W |
| Speed | 3,000 | min⁻¹ |
| Rated current | 1.9 | A |
| Rated torque | 0.1 | Nm |
| Maximum torque | 0.4 | Nm |
| Duty type | S1 | |
| Maximum current | 7.6 | A |
| Armature resistance | 2 | Ω |
| Armature inductance | 4 | mH |
| Operating data · Operating point 4 (48 V DC) | ||
| Rated voltage | 48 | V DC |
| Output power | 30 | W |
| Speed | 3,000 | min⁻¹ |
| Rated current | 0.9 | A |
| Rated torque | 0.1 | Nm |
| Maximum torque | 0.4 | Nm |
| Duty type | S1 | |
| Maximum current | 3.8 | A |
| Armature resistance | 6.7 | Ω |
| Armature inductance | 15 | mH |
| Operating data · Operating point 5 (170 V DC) | ||
| Rated voltage | 170 | V DC |
| Output power | 30 | W |
| Speed | 3,000 | min⁻¹ |
| Rated current | 0.3 | A |
| Rated torque | 0.1 | Nm |
| Maximum torque | 0.4 | Nm |
| Duty type | S1 | |
| Maximum current | 1.2 | A |
| Armature resistance | 66 | Ω |
| Armature inductance | 130 | mH |
| Design and mechanics | ||
| Housing diameter | 65 | mm |
| Mounting | Depending on version | |
| Base motor rotor inertia | 0.00004 | kg·m² |
| Equipment | ||
| Motor design | Permanent magnet DC motor | |
| Degree of protection | IP40 | |
| Insulation class | F | |
| Cooling | Without fan | |
| Connection | Lead wires | |
| Bearings | Ball bearings | |
Series illustration; see data for configuration.
Unspecified values or values awaiting confirmation: on request. S6 duty and permissible overload: on request. Maximum current is not a permissible continuous current.
- Product type: three-phase asynchronous motor
- Rated power: 1,10 kW; 1,32 kW
- Speed: 1445 min-1; 1734 min-1
- Voltage: 230 V Δ / 400 V Y; 265 V Δ / 460 V Y
- Frequency: 50 Hz; 60 Hz
- Duty type: S1
- Efficiency class: IE3
- Torque: 7,27 Nm
- Standards: IEC 60034-1; IEC 60034-9
- Protection class: IP55
- Product type: three-phase asynchronous motor
- Rated power: 1,10 kW; 1,32 kW
- Speed: 1445 min-1; 1734 min-1
- Voltage: 230 V Δ / 400 V Y; 265 V Δ / 460 V Y
- Frequency: 50 Hz; 60 Hz
- Duty type: S1
- Efficiency class: IE3
- Torque: 7,27 Nm
- Standards: IEC 60034-1; IEC 60034-9
- Protection class: IP55
- Product type: three-phase asynchronous motor
- Rated power: 0,75 kW; 0,90 kW
- Speed: 1430 min-1; 1716 min-1
- Voltage: 230 V Δ / 400 V Y; 265 V Δ / 460 V Y
- Frequency: 50 Hz; 60 Hz
- Duty type: S1
- Efficiency class: IE4
- Torque: 5,01 Nm
- Standards: IEC 60034-1; IEC 60034-9
- Protection class: IP55
- Foot mounting: Removable feet (terminal box can be repositioned).
- Colour: RAL7030
Sinusoidal output voltage for cost-efficient and problem-free operation with long motor supply line.
Price including Cu surcharge and metal surcharge
• Output voltage becomes sinusoidal without voltage peaks
• Reduction of EMV problems
• High damping of noise emissions of the line
• Reduction of eddy current losses in the motor
• Savings on the shielded line possible
• Extended life for electrical consumers
• Increase the life of bearings by reducing bearing flows
• Motor frequency up to 200 Hz
Corrosion and moisture protection by complete vacuum impregnation, maximum
ambient temperature 40°C, insulation class B, protection class IP00, suitable for installation up to IP23,
with separate capacitor plate and 2m connection cable
according to VDE 0570 DIN EN 61558-2-20
Technical details
Rated voltage: Small 3x500V
maximum voltage ripples: 5%
Engine frequency: 0 -70 Hz (>70 Hz with Derating)
Short-circuit voltage Uk: 8% (for 400V 50 Hz)
Maximum length of supply line to the motor:
600m (unshielded); 1000 meters (shielded)
- IP55
- 0,37 kW
- S1
- 935 1/min
- 230 V, 50 Hz ±5%
- 2,48 A
- End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
- Temperature protection: incl. 1 x PTC- PTC resistor
- terminal box layer at top
- housing of die cast aluminium
- Motor feet can be screwed on or unscrewed
- AC motors are suitable for both directions of rotation
- with operating capacitor nominal power at max 40° C and up to 1000 m above NN
- dynamically balanced with half paste spring inserted
- Vibration level "N"
- incl. EG installation declaration with disassembly, operation & maintenance instructions
- Due to the start-up and operating capacitor, the 230V motor has a stronger start-up torque.
- The start-up capacitor is switched off by a centrifugal force switch when the speed is reached.
- At low load, the temperature in the engine increases sharply and this can lead to failures.
- Therefore, it is recommended that single-phase motors should not be operated at a load below 25 % of the rated load.
MP80.05X — Permanent magnet DC motor
Series overview. The operating points and mechanics of the selected article variant apply.
| Parameter | Value | Unit |
|---|---|---|
| Operating data · Operating point 1 (24 V DC) | ||
| Rated voltage | 24 | V DC |
| Output power | 350 | W |
| Speed | 3,000 | min⁻¹ |
| Rated current | On request | A |
| Rated torque | 1.114 (calculated) | Nm |
| Duty type | S1 | |
| Operating data · Operating point 2 (48 V DC) | ||
| Rated voltage | 48 | V DC |
| Output power | 350 | W |
| Speed | 3,000 | min⁻¹ |
| Rated current | On request | A |
| Rated torque | 1.114 (calculated) | Nm |
| Duty type | S1 | |
| Design and mechanics | ||
| Housing diameter | 110 | mm |
| Mounting | Depending on version | |
| Equipment | ||
| Motor design | Permanent magnet DC motor | |
| Degree of protection | IP40 | |
| Insulation class | F | |
| Cooling | Without fan | |
| Connection | Lead wires | |
| Bearings | Ball bearings | |
Series illustration; see data for configuration.
Unspecified values or values awaiting confirmation: on request. S6 duty and permissible overload: on request. Maximum current is not a permissible continuous current.
Pole-changing three-phase motor - Fan drive
| Motor frame size | 80K |
|---|---|
| Number of poles | 6/4 |
| Output power | 0.16/0.55 kW |
| Synchronous speed at 50 Hz | 1000/1500 min-1 |
| Application | Fan drive |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Y/Y - Separate windings |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.
Pole-changing three-phase motor - Constant torque
| Motor frame size | 80K |
|---|---|
| Number of poles | 6/4 |
| Output power | 0.2/0.28 kW |
| Synchronous speed at 50 Hz | 1000/1500 min-1 |
| Application | Constant torque |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Y/Y - Separate windings |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.
Missing dimensions and version-specific dimensioned drawings on request.
Important compatibility information: This component is intended exclusively for the corresponding stator housing in our Grey cast iron housing series, in the matching frame size and version. It is not compatible with motors, housings or components from other manufacturers or product series. The same frame size alone does not guarantee a fit. Please have the exact match and connection dimensions checked before ordering.
Bearing cover – grey cast iron, IEC frame 355, outside.
End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
with operating capacitor and starting capacitor Ma/Mn 2,50
Maximum rated power at maximum 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
- Colour: RAL7030
- Rated output P2 [kW]: 1.1
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Specified speed [min−1]: 2800
- Rated current [A]: 7.02
- Starting torque / rated torque: 2.50
- Frame size: 80
- Number of poles: 2
- Degree of protection: IP55
- Insulation class: F
- Ambient temperature: ≤ +40 °C
- Installation altitude up to [m]: 1000
- Vibration grade: N
- Mounting arrangement: Variants as selected
- Shaft end D × E [mm]: 19 × 40
- With run and start capacitors
- Dynamically balanced with half key
- Shaft end including key
- Removable feet; rotatable terminal box
Missing dimensions and version-specific dimensioned drawings on request.
Important compatibility information: This component is intended exclusively for the corresponding stator housing in our Grey cast iron housing series, in the matching frame size and version. It is not compatible with motors, housings or components from other manufacturers or product series. The same frame size alone does not guarantee a fit. Please have the exact match and connection dimensions checked before ordering.
Bearing cover – grey cast iron, IEC frame 355, inside.
- Length: 1 m
- Version: Standard
- Connection: Motor – Control circuit
- Mass: 0.23 kg
Check the connector configuration and electrical assignment before connection.
- Rated output P2 [kW]: 0.75
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Specified speed [min−1]: 1400
- Rated current [A]: 5.22
- Starting torque / rated torque: 2.50
- Frame size: 80
- Number of poles: 4
- Degree of protection: IP55
- Insulation class: F
- Ambient temperature: ≤ +40 °C
- Installation altitude up to [m]: 1000
- Vibration grade: N
- Mounting arrangement: Variants as selected
- Shaft end D × E [mm]: 19 × 40
- With run and start capacitors
- Dynamically balanced with half key
- Shaft end including key
- Removable feet; rotatable terminal box
End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
with operating capacitor and starting capacitor Ma/Mn 2,50
Maximum rated power at maximum 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
- Colour: RAL7030
Power values correspond to fan design (square torque)
attracting current 6,0/7,0 x In; starting torque 1,6/1,8 x Mn; tilting moment 1,8 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø24 x 50 mm; Heat class 155(F)
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; Moment of inertia 0,0009 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic
- Foot mounting: Removable feet (terminal box can be repositioned).
- Colour: RAL7030
Power values correspond to fan design (square torque)
attracting current 4,5/6 x In; starting torque 1,5/1,5 x Mn; tilting moment 1,8 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø24 x 50 mm; Heat class 155(F)
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; Moment of inertia 0,0009 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic
- Foot mounting: Removable feet (terminal box can be repositioned).
- Colour: RAL7030
Pole-changing three-phase motor
| Operating data | Fan application / 4 | Fan application / 2 |
|---|---|---|
| Number of poles | 4 | 2 |
| Rated output [kW] | 0.07 | 0.28 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | YY |
| Rated current [A] | 0.3 | 1.25 |
| Rated speed [min-1] | 1400 | 2800 |
| Rated torque [N·m] | 0.48 | 0.96 |
| Efficiency at rated load [%] | 58 | 50 |
| Power factor cos φ | 0.7 | 0.7 |
| Starting current / rated current | 2.9 | 2.7 |
| Starting torque / rated torque | 2.2 | 2.1 |
| Breakdown torque / rated torque | 1.4 | 2.3 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 71 |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 4.9 |
| Moment of inertia [kg·m²] | 0.000606 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Operating data | Standard application / 4 | Standard application / 2 |
|---|---|---|
| Number of poles | 4 | 2 |
| Rated output [kW] | 0.21 | 0.28 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Δ | YY |
| Rated current [A] | 0.95 | 1.25 |
| Rated speed [min-1] | 1400 | 2800 |
| Rated torque [N·m] | 1.43 | 0.96 |
| Efficiency at rated load [%] | 58 | 50 |
| Power factor cos φ | 0.6 | 0.7 |
| Starting current / rated current | 3.2 | 3.2 |
| Starting torque / rated torque | 1.6 | 1.6 |
| Breakdown torque / rated torque | 2 | 1.8 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 71 |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 4.9 |
| Moment of inertia [kg·m²] | 0.000606 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
- single-phase circular saw motor
- Power = 1,1 kW
- Speed = 2770 rpm
- Type of flange = clamping flange
- Saw blade bore = 25,4mm
- Direction of rotation=right
- Shaft thread=left, single-phase motor
- Voltage = 1 x 230 V (± 5% according to VDE 0530)
- Frequency = 50Hz
- Electricity = 7,18A
- Structure = B34
- Weight = 9,35kg
- Degree of protection = IP55
- Operating mode = S6-40% ED
- terminal box position=right
- Temperature sensors=3 x thermo sensor opener (PTO)
- Ball bearing = , C&U, o.
- Equivalent
- Cooling = axial fan
- Motor feet=fixed.
- According to VDE 0105, i.e.
- IEC 364 all work on the electric drive is to be carried out only by qualified specialists.
- Three-phase circular saw motor
- Power = 1,5 kW
- Speed = 2750 rpm
- Type of flange = clamping flange
- Saw blade bore = 25,4mm
- Direction of rotation=right
- Shaft thread = left
- Electricity = 3,41A
- Voltage = 3 x 230/400 V-50 Hz, 3 x 265/460 V-60 Hz (± 5% according to VDE 0530)
- Structure = B34
- Weight = 9,6kg
- Degree of protection = IP55
- Operating mode = S6-40% ED
- terminal box position=right
- Temperature sensors=3 x thermo sensor opener (PTO)
- Ball bearing = , C&U, o.
- Equivalent
- Cooling = axial fan
- Motor feet=fixed.
- According to VDE 0105, i.e.
- IEC 364 all work on the electric drive is to be carried out only by qualified specialists.
- material: steel, galvanized surface
- with 4x motor mounting bolts M20x68 with nut
- with 2x tensioning screws
- with adjustable tensioning blocks
- anchoring to the industrial floor using foundation blocks according to DIN 799
- comprising 2x slide rails (2x = 1 Set)
Pole-changing three-phase motor - Constant torque
| Motor frame size | 80G |
|---|---|
| Number of poles | 4/2 |
| Output power | 0.7/0.85 kW |
| Synchronous speed at 50 Hz | 1500/3000 min-1 |
| Application | Constant torque |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Δ/YY - Dahlander |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.
Pole-changing three-phase motor - Fan drive
| Motor frame size | 80G |
|---|---|
| Number of poles | 6/4 |
| Output power | 0.2/0.6 kW |
| Synchronous speed at 50 Hz | 1000/1500 min-1 |
| Application | Fan drive |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Y/Y - Separate windings |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.
Pole-changing three-phase motor - Constant torque
| Motor frame size | 80G |
|---|---|
| Number of poles | 8/4 |
| Output power | 0.25/0.45 kW |
| Synchronous speed at 50 Hz | 750/1500 min-1 |
| Application | Constant torque |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Δ/YY - Dahlander |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.