KEMMERICH ELEKTROMOTOREN
Items 1 - 4 of 4
Switchable for constant or square torque.
17/27 kW; S1; 740/1470 min-1; 400V Δ/YY 50 Hz 3AC; 40,0/48,5 A; 219/175 Nm
attract current 6,0/6,9xIn; starting torque 2,7/1,8xMn; tilting moment 2,7/2,4xMn
Efficiency 85,2/87,6%
Power values Basic design (constant torque)
7,0/28 kW; S1; 735/1470 min-1; 400V Y/YY 50 Hz 3AC 14,8/54,0 A; 91/182 Nm
attract current 5,2/6,3xIn; starting torque 1,8/2,1xMn; tilting moment 2,3/2,6xMn
Efficiency 84,5/89,7%
Power values Fan design (square torque)
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø55 x 110 mm; heat class 155(F); incl. 3x PTC temperature sensors
Housing material up to frame size 112 aluminum, from frame size 132 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: NU312.C3; Camp BS: 6312.C3; Moment of inertia 0,47 kgm2
half-wedge weighting species; vibration stage "A"; Insulation class F
sound pressure level 60/69 dB; terminal box position on the right; Number of terminals 9
Paint RAL5010
17/27 kW; S1; 740/1470 min-1; 400V Δ/YY 50 Hz 3AC; 40,0/48,5 A; 219/175 Nm
attract current 6,0/6,9xIn; starting torque 2,7/1,8xMn; tilting moment 2,7/2,4xMn
Efficiency 85,2/87,6%
Power values Basic design (constant torque)
7,0/28 kW; S1; 735/1470 min-1; 400V Y/YY 50 Hz 3AC 14,8/54,0 A; 91/182 Nm
attract current 5,2/6,3xIn; starting torque 1,8/2,1xMn; tilting moment 2,3/2,6xMn
Efficiency 84,5/89,7%
Power values Fan design (square torque)
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø55 x 110 mm; heat class 155(F); incl. 3x PTC temperature sensors
Housing material up to frame size 112 aluminum, from frame size 132 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: NU312.C3; Camp BS: 6312.C3; Moment of inertia 0,47 kgm2
half-wedge weighting species; vibration stage "A"; Insulation class F
sound pressure level 60/69 dB; terminal box position on the right; Number of terminals 9
Paint RAL5010
- PROTECTION DEGREE: IP54
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 4
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 840 min-1
- RATED FREQUENCY: 28,9 Hz
- OUTPUT POWER: 27,0 kW (S1) / 38,2 kW (S6-40%)
- RATED TORQUE: 310 Nm (S1) / 435 Nm (S6-40%)
- RATED CURRENT: 53,0 A (S1) / 74,2 A (S6-40%)
- EFFICIENCY: 89,0 %
- CONSTANT-POWER RANGE max.: 1900 min-1 (S1) / 1350 min-1 (S6-40%)
- COOLING: IC416A, standard fan 3x400 Vac 50/60 Hz 0,22/0,26A 110/160W
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: (4000 min-1 roller bearing; may be further limited by encoder feedback or brake
- DIMENSIONS B/O: 510 / 770 mm
- MOMENT OF INERTIA J: 0,25 kgm2
- ARTICLE WEIGHT: 275,00 kg
- PROTECTION DEGREE: IP54 (IP55 on request)
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 4
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2020 min-1
- RATED FREQUENCY: 69,3 Hz
- OUTPUT POWER: 27,0 kW (S1) / 35,0 kW (S6-40%)
- RATED TORQUE: 128 Nm (S1) / 165,5 Nm (S6-40%)
- RATED CURRENT: 52,5 A (S1) / 66,5 A (S6-40%)
- EFFICIENCY: 90,5 %
- CONSTANT-POWER RANGE max.: 5000 min-1 (S1) / 2750 min-1 (S6-40%)
- COOLANT / COOLING: liquid refrigeration; Water 20° C. +max. 20 % ethylene glycol
- VOLUMETRIC FLOW / COOLING CAPACITY: 16 L/min; Recommended min. radiator waste heat output 3,8 kW
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1 (4500 min-1 in the case of roller bearings; S4 to 10000 min-1; may be further limited by encoder feedback or brake
- DIMENSIONS q/B/O/X/Y: 376 / 411 / 520 / 200 / 210 mm
- MOMENT OF INERTIA J: 0,0386 kgm2
- PROTECTION DEGREE: IP54 (IP55 on request)
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 4
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1580 min-1
- RATED FREQUENCY: 54,3 Hz
- OUTPUT POWER: 27,0 kW (S1) / 35,1 kW (S6-40%)
- RATED TORQUE: 163 Nm (S1) / 212 Nm (S6-40%)
- RATED CURRENT: 52,0 A (S1) / 65,5 A (S6-40%)
- EFFICIENCY: 89,5 %
- CONSTANT-POWER RANGE max.: 4300 min-1 (S1) / 3150 min-1 (S6-40%)
- COOLANT / COOLING: liquid refrigeration; Water 20° C. +max. 20 % ethylene glycol
- VOLUMETRIC FLOW / COOLING CAPACITY: 12 L/min; Recommended min. radiator waste heat output 4,4 kW
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 6500 min-1 (4000 min-1 in the case of roller bearings; S4 to 9000 min-1; may be further limited by encoder feedback or brake
- DIMENSIONS q/B/O/X/Y/Z: 213 / 252 / 400 / 200 / 140 / 245 mm
- MOMENT OF INERTIA J: 0,068 kgm2
- ARTICLE WEIGHT: 114,00 kg
Items 1 - 4 of 4