KEMMERICH ELEKTROMOTOREN
Items 1 - 40 of 123
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4340 min-1
- RATED FREQUENCY: 72,7 Hz
- OUTPUT POWER: 125 kW (S1) / 163 kW (S6-40%)
- RATED TORQUE: 275 Nm (S1) / 358 Nm (S6-40%)
- RATED CURRENT: 206 A (S1) / 269 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 9500 min-1 (S1) / 7600 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 125 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,31 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 5690 min-1
- RATED FREQUENCY: 95,3 Hz
- OUTPUT POWER: 139 kW (S1) / 181 kW (S6-40%)
- RATED TORQUE: 234 Nm (S1) / 304 Nm (S6-40%)
- RATED CURRENT: 223 A (S1) / 294 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 9400 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 170 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,31 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4280 min-1
- RATED FREQUENCY: 71,7 Hz
- OUTPUT POWER: 123 kW (S1) / 160 kW (S6-40%)
- RATED TORQUE: 275 Nm (S1) / 358 Nm (S6-40%)
- RATED CURRENT: 177 A (S1) / 230 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 9350 min-1 (S1) / 7500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 120 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,31 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 5890 min-1
- RATED FREQUENCY: 98,6 Hz
- OUTPUT POWER: 144 kW (S1) / 187 kW (S6-40%)
- RATED TORQUE: 234 Nm (S1) / 304 Nm (S6-40%)
- RATED CURRENT: 200 A (S1) / 264 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 9750 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 185 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,31 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4320 min-1
- RATED FREQUENCY: 72,4 Hz
- OUTPUT POWER: 144 kW (S1) / 187 kW (S6-40%)
- RATED TORQUE: 318 Nm (S1) / 414 Nm (S6-40%)
- RATED CURRENT: 228 A (S1) / 305 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 9600 min-1 (S1) / 7800 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 145 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,36 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 5490 min-1
- RATED FREQUENCY: 91,9 Hz
- OUTPUT POWER: 154 kW (S1) / 200 kW (S6-40%)
- RATED TORQUE: 267 Nm (S1) / 347 Nm (S6-40%)
- RATED CURRENT: 245 A (S1) / 321 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 9500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 190 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,36 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4470 min-1
- RATED FREQUENCY: 74,9 Hz
- OUTPUT POWER: 149 kW (S1) / 194 kW (S6-40%)
- RATED TORQUE: 318 Nm (S1) / 414 Nm (S6-40%)
- RATED CURRENT: 205 A (S1) / 275 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 9950 min-1 (S1) / 8050 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 155 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,36 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 5610 min-1
- RATED FREQUENCY: 93,9 Hz
- OUTPUT POWER: 157 kW (S1) / 204 kW (S6-40%)
- RATED TORQUE: 267 Nm (S1) / 347 Nm (S6-40%)
- RATED CURRENT: 218 A (S1) / 285 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 9700 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 200 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,36 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4090 min-1
- RATED FREQUENCY: 68,6 Hz
- OUTPUT POWER: 159 kW (S1) / 206 kW (S6-40%)
- RATED TORQUE: 370 Nm (S1) / 481 Nm (S6-40%)
- RATED CURRENT: 259 A (S1) / 336 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 8000 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 165 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,42 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 5330 min-1
- RATED FREQUENCY: 89,1 Hz
- OUTPUT POWER: 173 kW (S1) / 225 kW (S6-40%)
- RATED TORQUE: 310 Nm (S1) / 403 Nm (S6-40%)
- RATED CURRENT: 274 A (S1) / 359 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 9800 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 220 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,42 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4180 min-1
- RATED FREQUENCY: 70,1 Hz
- OUTPUT POWER: 162 kW (S1) / 211 kW (S6-40%)
- RATED TORQUE: 370 Nm (S1) / 481 Nm (S6-40%)
- RATED CURRENT: 230 A (S1) / 299 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 8200 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 175 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,42 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 5360 min-1
- RATED FREQUENCY: 89,7 Hz
- OUTPUT POWER: 174 kW (S1) / 226 kW (S6-40%)
- RATED TORQUE: 310 Nm (S1) / 403 Nm (S6-40%)
- RATED CURRENT: 239 A (S1) / 314 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 9850 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 225 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,42 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3940 min-1
- RATED FREQUENCY: 66,0 Hz
- OUTPUT POWER: 182 kW (S1) / 237 kW (S6-40%)
- RATED TORQUE: 442 Nm (S1) / 575 Nm (S6-40%)
- RATED CURRENT: 295 A (S1) / 369 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 8800 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 210 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,48 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 5120 min-1
- RATED FREQUENCY: 85,6 Hz
- OUTPUT POWER: 200 kW (S1) / 260 kW (S6-40%)
- RATED TORQUE: 372 Nm (S1) / 484 Nm (S6-40%)
- RATED CURRENT: 316 A (S1) / 418 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 9700 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 250 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,48 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3960 min-1
- RATED FREQUENCY: 66,4 Hz
- OUTPUT POWER: 183 kW (S1) / 238 kW (S6-40%)
- RATED TORQUE: 442 Nm (S1) / 575 Nm (S6-40%)
- RATED CURRENT: 258 A (S1) / 323 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 8850 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 210 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,48 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 5040 min-1
- RATED FREQUENCY: 84,4 Hz
- OUTPUT POWER: 197 kW (S1) / 256 kW (S6-40%)
- RATED TORQUE: 372 Nm (S1) / 484 Nm (S6-40%)
- RATED CURRENT: 271 A (S1) / 358 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 9550 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 245 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,48 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3570 min-1
- RATED FREQUENCY: 59,8 Hz
- OUTPUT POWER: 214 kW (S1) / 278 kW (S6-40%)
- RATED TORQUE: 570 Nm (S1) / 745 Nm (S6-40%)
- RATED CURRENT: 356 A (S1) / 503 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 8500 min-1 (S1) / 6400 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 180 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,92 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4660 min-1
- RATED FREQUENCY: 78,0 Hz
- OUTPUT POWER: 238 kW (S1) / 309 kW (S6-40%)
- RATED TORQUE: 485 Nm (S1) / 635 Nm (S6-40%)
- RATED CURRENT: 383 A (S1) / 546 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 7600 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 235 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,92 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3520 min-1
- RATED FREQUENCY: 58,9 Hz
- OUTPUT POWER: 211 kW (S1) / 274 kW (S6-40%)
- RATED TORQUE: 570 Nm (S1) / 745 Nm (S6-40%)
- RATED CURRENT: 305 A (S1) / 431 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 8400 min-1 (S1) / 6300 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 170 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,92 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4470 min-1
- RATED FREQUENCY: 74,7 Hz
- OUTPUT POWER: 228 kW (S1) / 296 kW (S6-40%)
- RATED TORQUE: 485 Nm (S1) / 635 Nm (S6-40%)
- RATED CURRENT: 319 A (S1) / 455 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 9600 min-1 (S1) / 7300 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 215 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,92 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3450 min-1
- RATED FREQUENCY: 57,7 Hz
- OUTPUT POWER: 257 kW (S1) / 334 kW (S6-40%)
- RATED TORQUE: 710 Nm (S1) / 925 Nm (S6-40%)
- RATED CURRENT: 427 A (S1) / 547 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 9000 min-1 (S1) / 6800 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 225 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,1 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4700 min-1
- RATED FREQUENCY: 78,6 Hz
- OUTPUT POWER: 289 kW (S1) / 375 kW (S6-40%)
- RATED TORQUE: 585 Nm (S1) / 765 Nm (S6-40%)
- RATED CURRENT: 462 A (S1) / 598 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 8800 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 330 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,1 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3310 min-1
- RATED FREQUENCY: 55,3 Hz
- OUTPUT POWER: 246 kW (S1) / 320 kW (S6-40%)
- RATED TORQUE: 710 Nm (S1) / 925 Nm (S6-40%)
- RATED CURRENT: 356 A (S1) / 456 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 8650 min-1 (S1) / 6500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 210 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,1 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4320 min-1
- RATED FREQUENCY: 72,3 Hz
- OUTPUT POWER: 265 kW (S1) / 345 kW (S6-40%)
- RATED TORQUE: 585 Nm (S1) / 765 Nm (S6-40%)
- RATED CURRENT: 370 A (S1) / 479 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 8100 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 280 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,1 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 375 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4650 min-1
- RATED FREQUENCY: 77,7 Hz
- OUTPUT POWER: 361 kW (S1) / 469 kW (S6-40%)
- RATED TORQUE: 740 Nm (S1) / 965 Nm (S6-40%)
- RATED CURRENT: 616 A (S1) / 796 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 9800 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 460 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,4 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3470 min-1
- RATED FREQUENCY: 58,0 Hz
- OUTPUT POWER: 320 kW (S1) / 417 kW (S6-40%)
- RATED TORQUE: 880 Nm (S1) / 1145 Nm (S6-40%)
- RATED CURRENT: 525 A (S1) / 676 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 9700 min-1 (S1) / 7500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 310 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,4 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3190 min-1
- RATED FREQUENCY: 53,4 Hz
- OUTPUT POWER: 295 kW (S1) / 383 kW (S6-40%)
- RATED TORQUE: 880 Nm (S1) / 1145 Nm (S6-40%)
- RATED CURRENT: 420 A (S1) / 541 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 8900 min-1 (S1) / 6900 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 265 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,4 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4280 min-1
- RATED FREQUENCY: 71,5 Hz
- OUTPUT POWER: 332 kW (S1) / 432 kW (S6-40%)
- RATED TORQUE: 740 Nm (S1) / 965 Nm (S6-40%)
- RATED CURRENT: 462 A (S1) / 597 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 9000 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 390 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,4 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 310 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4550 min-1
- RATED FREQUENCY: 76,0 Hz
- OUTPUT POWER: 449 kW (S1) / 583 kW (S6-40%)
- RATED TORQUE: 940 Nm (S1) / 1225 Nm (S6-40%)
- RATED CURRENT: 915 A (S1) / 1188 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 10000 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 583 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,7 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3620 min-1
- RATED FREQUENCY: 60,6 Hz
- OUTPUT POWER: 414 kW (S1) / 538 kW (S6-40%)
- RATED TORQUE: 1090 Nm (S1) / 1420 Nm (S6-40%)
- RATED CURRENT: 685 A (S1) / 872 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 8500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 455 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,7 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3120 min-1
- RATED FREQUENCY: 52,3 Hz
- OUTPUT POWER: 357 kW (S1) / 464 kW (S6-40%)
- RATED TORQUE: 1090 Nm (S1) / 1420 Nm (S6-40%)
- RATED CURRENT: 514 A (S1) / 654 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 9900 min-1 (S1) / 7350 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 340 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,7 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4500 min-1
- RATED FREQUENCY: 75,1 Hz
- OUTPUT POWER: 444 kW (S1) / 577 kW (S6-40%)
- RATED TORQUE: 940 Nm (S1) / 1225 Nm (S6-40%)
- RATED CURRENT: 610 A (S1) / 792 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 10000 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 577 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,7 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2990 min-1
- RATED FREQUENCY: 50,1 Hz
- OUTPUT POWER: 360 kW (S1) / 470 kW (S6-40%)
- RATED TORQUE: 1150 Nm (S1) / 1500 Nm (S6-40%)
- RATED CURRENT: 590 A (S1) / 770 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 7200 min-1 (S1) / 5400 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 280 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 7000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 2,28 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4010 min-1
- RATED FREQUENCY: 67,1 Hz
- OUTPUT POWER: 420 kW (S1) / 546 kW (S6-40%)
- RATED TORQUE: 1000 Nm (S1) / 1300 Nm (S6-40%)
- RATED CURRENT: 675 A (S1) / 880 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 8700 min-1 (S1) / 7000 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 425 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 7000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 2,28 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2860 min-1
- RATED FREQUENCY: 47,9 Hz
- OUTPUT POWER: 345 kW (S1) / 450 kW (S6-40%)
- RATED TORQUE: 1150 Nm (S1) / 1500 Nm (S6-40%)
- RATED CURRENT: 495 A (S1) / 640 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 6900 min-1 (S1) / 5150 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 260 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 7000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 2,28 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4720 min-1
- RATED FREQUENCY: 78,9 Hz
- OUTPUT POWER: 470 kW (S1) / 610 kW (S6-40%)
- RATED TORQUE: 950 Nm (S1) / 1235 Nm (S6-40%)
- RATED CURRENT: 655 A (S1) / 860 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 9000 min-1 (S1) / 8500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 575 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 7000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 2,28 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2900 min-1
- RATED FREQUENCY: 48,5 Hz
- OUTPUT POWER: 455 kW (S1) / 592 kW (S6-40%)
- RATED TORQUE: 1500 Nm (S1) / 1950 Nm (S6-40%)
- RATED CURRENT: 735 A (S1) / 955 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 7400 min-1 (S1) / 5600 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 370 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 7000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 2,95 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4040 min-1
- RATED FREQUENCY: 67,5 Hz
- OUTPUT POWER: 550 kW (S1) / 715 kW (S6-40%)
- RATED TORQUE: 1300 Nm (S1) / 1690 Nm (S6-40%)
- RATED CURRENT: 880 A (S1) / 1135 A (S6-40%)
- EFFICIENCY: 96,5 %
- CONSTANT-POWER RANGE max.: 9000 min-1 (S1) / 7200 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 570 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 7000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 2,95 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2640 min-1
- RATED FREQUENCY: 44,2 Hz
- OUTPUT POWER: 426 kW (S1) / 560 kW (S6-40%)
- RATED TORQUE: 1540 Nm (S1) / 2025 Nm (S6-40%)
- RATED CURRENT: 600 A (S1) / 785 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 6750 min-1 (S1) / 5100 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 315 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 7000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 2,95 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4040 min-1
- RATED FREQUENCY: 67,5 Hz
- OUTPUT POWER: 550 kW (S1) / 715 kW (S6-40%)
- RATED TORQUE: 1300 Nm (S1) / 1690 Nm (S6-40%)
- RATED CURRENT: 763 A (S1) / 1703 A (S6-40%)
- EFFICIENCY: 96,5 %
- CONSTANT-POWER RANGE max.: 9000 min-1 (S1) / 7200 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 570 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 7000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 2,95 kgm2
Items 1 - 40 of 123