- Voltage: 230/400 V, 50 Hz
- Gear stages: 1
- Motor data: 45 W / 1400 min-1; 90 W / 1400 min-1; 120 W / 2800 min-1
- Permissible radial load: 150 N
- Permissible axial load: 100 N
- Degree of protection: 45 W: IP54; 90 W: IP54; 120 W: IP54
- n = output speed; M eff. = effective output torque; M max. = maximum permissible gear torque.
The maximum permissible gear torque must not be exceeded, even if the motor can deliver more torque.
- Product type: three-phase asynchronous motor
- Rated power: 0,12 kW; 0,14 kW
- Speed: 1310 1/min; 1572 1/min
- Voltage: 230 V Δ / 400 V Y; 265 V Δ / 460 V Y
- Frequency: 50 Hz; 60 Hz
- Duty type: S1
- Efficiency class: IE1
- Torque: 0,84 Nm
- Standards: IEC 60034-1; IEC 60034-9
- Foot mounting: Removable feet (terminal box can be repositioned).
- Product type: three-phase asynchronous motor
- Rated power: 0,06 kW; 0,07 kW
- Speed: 660 1/min; 800 1/min
- Voltage: 230 V Δ / 400 V Y; 265 V Δ / 460 V Y
- Frequency: 50 Hz; 60 Hz
- Duty type: S1
- Efficiency class: IE1
- Torque: 0,86 Nm
- Standards: IEC 60034-1; IEC 60034-9
- Voltage: 230/400 V, 50 Hz
- Gear stages: 2
- Motor data: 45 W / 1400 min-1; 90 W / 1400 min-1; 120 W / 2800 min-1
- Permissible radial load: 100 N
- Permissible axial load: 40 N
- Degree of protection: 45 W: IP54; 90 W: IP54; 120 W: IP54
- n = output speed; M eff. = effective output torque; M max. = maximum permissible gear torque.
The maximum permissible gear torque must not be exceeded, even if the motor can deliver more torque.
- Voltage: 230/400 V, 50 Hz
- Gear stages: 2
- Motor data: 45 W / 1400 min-1; 90 W / 1400 min-1; 120 W / 2800 min-1
- Permissible radial load: 100 N
- Permissible axial load: 40 N
- Degree of protection: 45 W: IP54; 90 W: IP54; 120 W: IP54
- n = output speed; M eff. = effective output torque; M max. = maximum permissible gear torque.
The maximum permissible gear torque must not be exceeded, even if the motor can deliver more torque.
- Voltage: 230/400 V, 50 Hz
- Gear stages: 1
- Motor data: 45 W / 1400 min-1; 90 W / 1400 min-1; 120 W / 2800 min-1
- Permissible radial load: 100 N
- Permissible axial load: 60 N
- Degree of protection: 45 W: IP54; 90 W: IP54; 120 W: IP54
- n = output speed; M eff. = effective output torque; M max. = maximum permissible gear torque.
The maximum permissible gear torque must not be exceeded, even if the motor can deliver more torque.
155 Watt at 2000 min-1, nominal 0,75 Nm, max. 3,75 Nm (B)
110 Watt at 1500 min-1, nominal 0,75 Nm, max 3,75 Nm (C)
• Degree of protection IP 54
• Moment of inertia 0,0003 kgm2
max. radial load 294 N
max axial load 88 N
• Insulation Class F
Low-noise ferrite permanent magnetic field with high coercive field strength
• Anchors for higher linearity
- Voltage: 230/400 V, 50 Hz
- Gear stages: 1
- Motor data: 32 W / 1400 min-1; 45 W / 1400 min-1; 90 W / 1400 min-1; 90 W / 2800 min-1; 120 W / 2800 min-1
- Permissible radial load: 150 N
- Permissible axial load: 100 N
- Degree of protection: 32 W: IP54; 45 W: IP54; 90 W: IP54; 90 W: IP54; 120 W: IP54
- n = output speed; M eff. = effective output torque; M max. = maximum permissible gear torque.
The maximum permissible gear torque must not be exceeded, even if the motor can deliver more torque.
- Voltage: 230/400 V, 50 Hz
- Gear stages: 1
- Motor data: 32 W / 1400 min-1; 45 W / 1400 min-1; 90 W / 1400 min-1; 90 W / 2800 min-1; 120 W / 2800 min-1
- Permissible radial load: 150 N
- Permissible axial load: 100 N
- Degree of protection: 32 W: IP54; 45 W: IP54; 90 W: IP54; 90 W: IP54; 120 W: IP54
- n = output speed; M eff. = effective output torque; M max. = maximum permissible gear torque.
The maximum permissible gear torque must not be exceeded, even if the motor can deliver more torque.
- Voltage: 230/400 V, 50 Hz
- Gear stages: 2
- Motor data: 45 W / 1400 min-1; 90 W / 1400 min-1; 120 W / 2800 min-1
- Permissible radial load: 80 N
- Permissible axial load: 30 N
- Degree of protection: 45 W: IP54; 90 W: IP54; 120 W: IP54
- n = output speed; M eff. = effective output torque; M max. = maximum permissible gear torque.
The maximum permissible gear torque must not be exceeded, even if the motor can deliver more torque.