KEMMERICH ELEKTROMOTOREN
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1440 min-1
- RATED FREQUENCY: 72,5 Hz
- OUTPUT POWER: 365 kW (S1) / 474 kW (S6-40%)
- RATED TORQUE: 2420 Nm (S1) / 3145 Nm (S6-40%)
- RATED CURRENT: 583 A (S1) / 736 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 3650 min-1 (S1) / 2850 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 225 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 6000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 4000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 3,9 kgm2
- ARTICLE WEIGHT: 1265,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1940 min-1
- RATED FREQUENCY: 97,7 Hz
- OUTPUT POWER: 475 kW (S1) / 617 kW (S6-40%)
- RATED TORQUE: 2340 Nm (S1) / 3040 Nm (S6-40%)
- RATED CURRENT: 756 A (S1) / 957 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 5000 min-1 (S1) / 3900 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 401 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 6000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 4000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 3,9 kgm2
- ARTICLE WEIGHT: 1265,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1030 min-1
- RATED FREQUENCY: 52,0 Hz
- OUTPUT POWER: 340 kW (S1) / 442 kW (S6-40%)
- RATED TORQUE: 3150 Nm (S1) / 4100 Nm (S6-40%)
- RATED CURRENT: 635 A (S1) / 830 A (S6-40%)
- EFFICIENCY: 93,5 %
- CONSTANT-POWER RANGE max.: 1800 min-1 (S1) / 1350 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 119 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 7,0 kgm2
- ARTICLE WEIGHT: 1470,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1520 min-1
- RATED FREQUENCY: 76,5 Hz
- OUTPUT POWER: 490 kW (S1) / 637 kW (S6-40%)
- RATED TORQUE: 3080 Nm (S1) / 4000 Nm (S6-40%)
- RATED CURRENT: 900 A (S1) / 1152 A (S6-40%)
- EFFICIENCY: 94,5 %
- CONSTANT-POWER RANGE max.: 2550 min-1 (S1) / 2000 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 255 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 7,0 kgm2
- ARTICLE WEIGHT: 1470,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2100 min-1
- RATED FREQUENCY: 105,6 Hz
- OUTPUT POWER: 660 kW (S1) / 858 kW (S6-40%)
- RATED TORQUE: 3000 Nm (S1) / 3900 Nm (S6-40%)
- RATED CURRENT: 1190 A (S1) / 1565 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 3500 min-1 (S1) / 2700 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 463 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 7,0 kgm2
- ARTICLE WEIGHT: 1470,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 990 min-1
- RATED FREQUENCY: 49,8 Hz
- OUTPUT POWER: 327 kW (S1) / 425 kW (S6-40%)
- RATED TORQUE: 3150 Nm (S1) / 4100 Nm (S6-40%)
- RATED CURRENT: 529 A (S1) / 692 A (S6-40%)
- EFFICIENCY: 93,5 %
- CONSTANT-POWER RANGE max.: 1750 min-1 (S1) / 1300 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 110 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 7,0 kgm2
- ARTICLE WEIGHT: 1470,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1530 min-1
- RATED FREQUENCY: 77,0 Hz
- OUTPUT POWER: 493 kW (S1) / 640 kW (S6-40%)
- RATED TORQUE: 3080 Nm (S1) / 4000 Nm (S6-40%)
- RATED CURRENT: 788 A (S1) / 1008 A (S6-40%)
- EFFICIENCY: 94,5 %
- CONSTANT-POWER RANGE max.: 2550 min-1 (S1) / 2000 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 256 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 7,0 kgm2
- ARTICLE WEIGHT: 1470,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2170 min-1
- RATED FREQUENCY: 109,3 Hz
- OUTPUT POWER: 682 kW (S1) / 887 kW (S6-40%)
- RATED TORQUE: 3000 Nm (S1) / 3900 Nm (S6-40%)
- RATED CURRENT: 1070 A (S1) / 1410 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 3600 min-1 (S1) / 2800 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 496 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 7,0 kgm2
- ARTICLE WEIGHT: 1470,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 980 min-1
- RATED FREQUENCY: 49,5 Hz
- OUTPUT POWER: 420 kW (S1) / 546 kW (S6-40%)
- RATED TORQUE: 4090 Nm (S1) / 5320 Nm (S6-40%)
- RATED CURRENT: 775 A (S1) / 1105 A (S6-40%)
- EFFICIENCY: 94,0 %
- CONSTANT-POWER RANGE max.: 1800 min-1 (S1) / 1350 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 147 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 9,2 kgm2
- ARTICLE WEIGHT: 1780,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1540 min-1
- RATED FREQUENCY: 77,5 Hz
- OUTPUT POWER: 645 kW (S1) / 840 kW (S6-40%)
- RATED TORQUE: 4000 Nm (S1) / 5210 Nm (S6-40%)
- RATED CURRENT: 1175 A (S1) / 1520 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 2800 min-1 (S1) / 2150 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 361 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 9,2 kgm2
- ARTICLE WEIGHT: 1780,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2060 min-1
- RATED FREQUENCY: 103,7 Hz
- OUTPUT POWER: 840 kW (S1) / 1090 kW (S6-40%)
- RATED TORQUE: 3890 Nm (S1) / 5050 Nm (S6-40%)
- RATED CURRENT: 1495 A (S1) / 735 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 3600 min-1 (S1) / 2700 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 589 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 9,2 kgm2
- ARTICLE WEIGHT: 1780,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1000 min-1
- RATED FREQUENCY: 50,6 Hz
- OUTPUT POWER: 429 kW (S1) / 557 kW (S6-40%)
- RATED TORQUE: 4090 Nm (S1) / 5320 Nm (S6-40%)
- RATED CURRENT: 689 A (S1) / 980 A (S6-40%)
- EFFICIENCY: 94,0 %
- CONSTANT-POWER RANGE max.: 1850 min-1 (S1) / 1400 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 156 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 9,2 kgm2
- ARTICLE WEIGHT: 1780,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1590 min-1
- RATED FREQUENCY: 80,2 Hz
- OUTPUT POWER: 666 kW (S1) / 867 kW (S6-40%)
- RATED TORQUE: 4000 Nm (S1) / 5210 Nm (S6-40%)
- RATED CURRENT: 1058 A (S1) / 1370 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 2900 min-1 (S1) / 2200 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 382 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 9,2 kgm2
- ARTICLE WEIGHT: 1780,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2070 min-1
- RATED FREQUENCY: 104,3 Hz
- OUTPUT POWER: 844 kW (S1) / 1095 kW (S6-40%)
- RATED TORQUE: 3890 Nm (S1) / 5050 Nm (S6-40%)
- RATED CURRENT: 1308 A (S1) / 643 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 3600 min-1 (S1) / 2700 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 591 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 9,2 kgm2
- ARTICLE WEIGHT: 1780,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 990 min-1
- RATED FREQUENCY: 50,0 Hz
- OUTPUT POWER: 520 kW (S1) / 676 kW (S6-40%)
- RATED TORQUE: 5020 Nm (S1) / 6520 Nm (S6-40%)
- RATED CURRENT: 950 A (S1) / 1225 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 1850 min-1 (S1) / 1450 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 196 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 12 kgm2
- ARTICLE WEIGHT: 2100,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1570 min-1
- RATED FREQUENCY: 79,0 Hz
- OUTPUT POWER: 815 kW (S1) / 1060 kW (S6-40%)
- RATED TORQUE: 4960 Nm (S1) / 6450 Nm (S6-40%)
- RATED CURRENT: 1480 A (S1) / 1900 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 2950 min-1 (S1) / 2300 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 487 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 12 kgm2
- ARTICLE WEIGHT: 2100,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1920 min-1
- RATED FREQUENCY: 96,5 Hz
- OUTPUT POWER: 970 kW (S1) / 1260 kW (S6-40%)
- RATED TORQUE: 4830 Nm (S1) / 6270 Nm (S6-40%)
- RATED CURRENT: 1720 A (S1) / 2260 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 3400 min-1 (S1) / 2650 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 668 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 12 kgm2
- ARTICLE WEIGHT: 2100,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1040 min-1
- RATED FREQUENCY: 52,7 Hz
- OUTPUT POWER: 546 kW (S1) / 710 kW (S6-40%)
- RATED TORQUE: 5020 Nm (S1) / 6520 Nm (S6-40%)
- RATED CURRENT: 870 A (S1) / 1123 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 1950 min-1 (S1) / 1500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 213 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 12 kgm2
- ARTICLE WEIGHT: 2100,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1580 min-1
- RATED FREQUENCY: 79,5 Hz
- OUTPUT POWER: 820 kW (S1) / 1066 kW (S6-40%)
- RATED TORQUE: 4960 Nm (S1) / 6450 Nm (S6-40%)
- RATED CURRENT: 1295 A (S1) / 1663 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 2950 min-1 (S1) / 2300 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 490 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 12 kgm2
- ARTICLE WEIGHT: 2100,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1890 min-1
- RATED FREQUENCY: 95,1 Hz
- OUTPUT POWER: 955 kW (S1) / 1240 kW (S6-40%)
- RATED TORQUE: 4830 Nm (S1) / 6270 Nm (S6-40%)
- RATED CURRENT: 1474 A (S1) / 1937 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 3350 min-1 (S1) / 2600 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 645 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 12 kgm2
- ARTICLE WEIGHT: 2100,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1870 min-1
- RATED FREQUENCY: 94,0 Hz
- OUTPUT POWER: 1150 kW (S1) / 1495 kW (S6-40%)
- RATED TORQUE: 5870 Nm (S1) / 7640 Nm (S6-40%)
- RATED CURRENT: 2020 A (S1) / 2655 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 3450 min-1 (S1) / 2650 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 792 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 14 kgm2
- ARTICLE WEIGHT: 2400,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 990 min-1
- RATED FREQUENCY: 50,0 Hz
- OUTPUT POWER: 630 kW (S1) / 819 kW (S6-40%)
- RATED TORQUE: 6080 Nm (S1) / 7900 Nm (S6-40%)
- RATED CURRENT: 1145 A (S1) / 1477 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 2650 min-1 (S1) / 2050 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 336 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 14 kgm2
- ARTICLE WEIGHT: 2400,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1500 min-1
- RATED FREQUENCY: 75,5 Hz
- OUTPUT POWER: 945 kW (S1) / 1230 kW (S6-40%)
- RATED TORQUE: 6020 Nm (S1) / 7830 Nm (S6-40%)
- RATED CURRENT: 1705 A (S1) / 2195 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 2900 min-1 (S1) / 2250 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 554 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 14 kgm2
- ARTICLE WEIGHT: 2400,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1790 min-1
- RATED FREQUENCY: 90,1 Hz
- OUTPUT POWER: 1101 kW (S1) / 1430 kW (S6-40%)
- RATED TORQUE: 5870 Nm (S1) / 7640 Nm (S6-40%)
- RATED CURRENT: 1683 A (S1) / 2213 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 3300 min-1 (S1) / 2550 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 729 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 14 kgm2
- ARTICLE WEIGHT: 2400,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1030 min-1
- RATED FREQUENCY: 51,8 Hz
- OUTPUT POWER: 655 kW (S1) / 852 kW (S6-40%)
- RATED TORQUE: 6080 Nm (S1) / 7900 Nm (S6-40%)
- RATED CURRENT: 1030 A (S1) / 1327 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 2750 min-1 (S1) / 2150 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 366 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 14 kgm2
- ARTICLE WEIGHT: 2400,00 kg
- PROTECTION DEGREE: IP23
- SERIE: HIGH SPEED / S6
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1480 min-1
- RATED FREQUENCY: 74,4 Hz
- OUTPUT POWER: 932 kW (S1) / 1214 kW (S6-40%)
- RATED TORQUE: 6020 Nm (S1) / 7830 Nm (S6-40%)
- RATED CURRENT: 1460 A (S1) / 1880 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 2850 min-1 (S1) / 2200 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 534 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 5000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 3200 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 14 kgm2
- ARTICLE WEIGHT: 2400,00 kg
- PROTECTION DEGREE: IP54 (IP55 on request)
- RATED VOLTAGE: 340 V
- DATA BASIS: 400 Vac (PWM > 4 kHz)
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1000 min-1
- RATED FREQUENCY: 50,0 Hz
- OUTPUT POWER: 6,8 kW (S1) / 8,8 kW (S6-40%)
- RATED TORQUE: 65 Nm (S1) / 84 Nm (S6-40%)
- RATED CURRENT: 13,9 A (S1) / 18,0 A (S6-40%)
- EFFICIENCY: 89,0 %
- MAX. SPEED AT RATED POWER: 2450 min-1
- MAX. SPEED AT MAX. TORQUE: 1000 min-1
- MAX. TORQUE: 130 Nm
- COOLANT / COOLING: liquid refrigeration; Water 20° C. +max. 20 % ethylene glycol
- VOLUMETRIC FLOW / COOLING CAPACITY: 12 L/min; Recommended min. radiator waste heat output 1,1 kW
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1 (4500 min-1 For roller bearings; may be further limited by encoder feedback or brake
- DIMENSIONS q/B/O/X/Y: 146 / 181 / 290 / 140 / 195 mm
- MOMENT OF INERTIA J: 0,0128 kgm2
- BEMF: must be less than 500 Vac; for BEMF > 500 Vac, a specific electrical protection measure against overvoltage is required
- PROTECTION DEGREE: IP54 (IP55 on request)
- RATED VOLTAGE: 345 V
- DATA BASIS: 400 Vac (PWM > 4 kHz)
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1700 min-1
- RATED FREQUENCY: 85,0 Hz
- OUTPUT POWER: 11,2 kW (S1) / 14,6 kW (S6-40%)
- RATED TORQUE: 63 Nm (S1) / 82 Nm (S6-40%)
- RATED CURRENT: 21,6 A (S1) / 28,0 A (S6-40%)
- EFFICIENCY: 93,0 %
- MAX. SPEED AT RATED POWER: 3600 min-1
- MAX. SPEED AT MAX. TORQUE: 1700 min-1
- MAX. TORQUE: 130 Nm
- COOLANT / COOLING: liquid refrigeration; Water 20° C. +max. 20 % ethylene glycol
- VOLUMETRIC FLOW / COOLING CAPACITY: 12 L/min; Recommended min. radiator waste heat output 1,1 kW
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1 (4500 min-1 For roller bearings; may be further limited by encoder feedback or brake
- DIMENSIONS q/B/O/X/Y: 146 / 181 / 290 / 140 / 195 mm
- MOMENT OF INERTIA J: 0,0128 kgm2
- BEMF: must be less than 500 Vac; for BEMF > 500 Vac, a specific electrical protection measure against overvoltage is required
- PROTECTION DEGREE: IP54 (IP55 on request)
- RATED VOLTAGE: 370 V
- DATA BASIS: 400 Vac (PWM > 4 kHz)
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2500 min-1
- RATED FREQUENCY: 125,0 Hz
- OUTPUT POWER: 15,7 kW (S1) / 20,4 kW (S6-40%)
- RATED TORQUE: 60 Nm (S1) / 78 Nm (S6-40%)
- RATED CURRENT: 27,7 A (S1) / 35,5 A (S6-40%)
- EFFICIENCY: 93,5 %
- MAX. SPEED AT RATED POWER: 4200 min-1
- MAX. SPEED AT MAX. TORQUE: 2350 min-1
- MAX. TORQUE: 130 Nm
- COOLANT / COOLING: liquid refrigeration; Water 20° C. +max. 20 % ethylene glycol
- VOLUMETRIC FLOW / COOLING CAPACITY: 12 L/min; Recommended min. radiator waste heat output 1,4 kW
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1 (4500 min-1 For roller bearings; may be further limited by encoder feedback or brake
- DIMENSIONS q/B/O/X/Y: 146 / 181 / 290 / 140 / 195 mm
- MOMENT OF INERTIA J: 0,0128 kgm2
- BEMF: must be less than 500 Vac; for BEMF > 500 Vac, a specific electrical protection measure against overvoltage is required
- PROTECTION DEGREE: IP54 (IP55 on request)
- RATED VOLTAGE: 345 V
- DATA BASIS: 400 Vac (PWM > 4 kHz)
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1000 min-1
- RATED FREQUENCY: 50,0 Hz
- OUTPUT POWER: 10,2 kW (S1) / 13,3 kW (S6-40%)
- RATED TORQUE: 98 Nm (S1) / 127 Nm (S6-40%)
- RATED CURRENT: 20,4 A (S1) / 26,3 A (S6-40%)
- EFFICIENCY: 90,0 %
- MAX. SPEED AT RATED POWER: 2200 min-1
- MAX. SPEED AT MAX. TORQUE: 1000 min-1
- MAX. TORQUE: 190 Nm
- COOLANT / COOLING: liquid refrigeration; Water 20° C. +max. 20 % ethylene glycol
- VOLUMETRIC FLOW / COOLING CAPACITY: 12 L/min; Recommended min. radiator waste heat output 1,5 kW
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1 (4500 min-1 For roller bearings; may be further limited by encoder feedback or brake
- DIMENSIONS q/B/O/X/Y: 196 / 231 / 340 / 200 / 210 mm
- MOMENT OF INERTIA J: 0,0192 kgm2
- BEMF: must be less than 500 Vac; for BEMF > 500 Vac, a specific electrical protection measure against overvoltage is required
- PROTECTION DEGREE: IP54 (IP55 on request)
- RATED VOLTAGE: 360 V
- DATA BASIS: 400 Vac (PWM > 4 kHz)
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1700 min-1
- RATED FREQUENCY: 85,0 Hz
- OUTPUT POWER: 16,7 kW (S1) / 21,7 kW (S6-40%)
- RATED TORQUE: 94 Nm (S1) / 122 Nm (S6-40%)
- RATED CURRENT: 30,9 A (S1) / 39,8 A (S6-40%)
- EFFICIENCY: 93,0 %
- MAX. SPEED AT RATED POWER: 3000 min-1
- MAX. SPEED AT MAX. TORQUE: 1700 min-1
- MAX. TORQUE: 190 Nm
- COOLANT / COOLING: liquid refrigeration; Water 20° C. +max. 20 % ethylene glycol
- VOLUMETRIC FLOW / COOLING CAPACITY: 12 L/min; Recommended min. radiator waste heat output 1,6 kW
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1 (4500 min-1 For roller bearings; may be further limited by encoder feedback or brake
- DIMENSIONS q/B/O/X/Y: 196 / 231 / 340 / 200 / 210 mm
- MOMENT OF INERTIA J: 0,0192 kgm2
- BEMF: must be less than 500 Vac; for BEMF > 500 Vac, a specific electrical protection measure against overvoltage is required
- PROTECTION DEGREE: IP54 (IP55 on request)
- RATED VOLTAGE: 370 V
- DATA BASIS: 400 Vac (PWM > 4 kHz)
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2500 min-1
- RATED FREQUENCY: 125,0 Hz
- OUTPUT POWER: 23,5 kW (S1) / 30,6 kW (S6-40%)
- RATED TORQUE: 90 Nm (S1) / 117 Nm (S6-40%)
- RATED CURRENT: 41,5 A (S1) / 53,5 A (S6-40%)
- EFFICIENCY: 94,0 %
- MAX. SPEED AT RATED POWER: 3900 min-1
- MAX. SPEED AT MAX. TORQUE: 2400 min-1
- MAX. TORQUE: 190 Nm
- COOLANT / COOLING: liquid refrigeration; Water 20° C. +max. 20 % ethylene glycol
- VOLUMETRIC FLOW / COOLING CAPACITY: 12 L/min; Recommended min. radiator waste heat output 2,0 kW
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1 (4500 min-1 For roller bearings; may be further limited by encoder feedback or brake
- DIMENSIONS q/B/O/X/Y: 196 / 231 / 340 / 200 / 210 mm
- MOMENT OF INERTIA J: 0,0192 kgm2
- BEMF: must be less than 500 Vac; for BEMF > 500 Vac, a specific electrical protection measure against overvoltage is required
- PROTECTION DEGREE: IP54 (IP55 on request)
- RATED VOLTAGE: 335 V
- DATA BASIS: 400 Vac (PWM > 4 kHz)
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1000 min-1
- RATED FREQUENCY: 50,0 Hz
- OUTPUT POWER: 14,1 kW (S1) / 18,3 kW (S6-40%)
- RATED TORQUE: 135 Nm (S1) / 175 Nm (S6-40%)
- RATED CURRENT: 28,8 A (S1) / 37,6 A (S6-40%)
- EFFICIENCY: 91,0 %
- MAX. SPEED AT RATED POWER: 2600 min-1
- MAX. SPEED AT MAX. TORQUE: 1050 min-1
- MAX. TORQUE: 260 Nm
- COOLANT / COOLING: liquid refrigeration; Water 20° C. +max. 20 % ethylene glycol
- VOLUMETRIC FLOW / COOLING CAPACITY: 12 L/min; Recommended min. radiator waste heat output 1,8 kW
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1 (4500 min-1 For roller bearings; may be further limited by encoder feedback or brake
- DIMENSIONS q/B/O/X/Y: 246 / 281 / 390 / 200 / 210 mm
- MOMENT OF INERTIA J: 0,0264 kgm2
- BEMF: must be less than 500 Vac; for BEMF > 500 Vac, a specific electrical protection measure against overvoltage is required
- PROTECTION DEGREE: IP54 (IP55 on request)
- RATED VOLTAGE: 340 V
- DATA BASIS: 400 Vac (PWM > 4 kHz)
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1700 min-1
- RATED FREQUENCY: 85,0 Hz
- OUTPUT POWER: 23,1 kW (S1) / 30,0 kW (S6-40%)
- RATED TORQUE: 130 Nm (S1) / 169 Nm (S6-40%)
- RATED CURRENT: 44,5 A (S1) / 58,1 A (S6-40%)
- EFFICIENCY: 93,5 %
- MAX. SPEED AT RATED POWER: 3500 min-1
- MAX. SPEED AT MAX. TORQUE: 1550 min-1
- MAX. TORQUE: 260 Nm
- COOLANT / COOLING: liquid refrigeration; Water 20° C. +max. 20 % ethylene glycol
- VOLUMETRIC FLOW / COOLING CAPACITY: 12 L/min; Recommended min. radiator waste heat output 2,1 kW
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1 (4500 min-1 For roller bearings; may be further limited by encoder feedback or brake
- DIMENSIONS q/B/O/X/Y: 246 / 281 / 390 / 200 / 210 mm
- MOMENT OF INERTIA J: 0,0264 kgm2
- BEMF: must be less than 500 Vac; for BEMF > 500 Vac, a specific electrical protection measure against overvoltage is required
- PROTECTION DEGREE: IP54 (IP55 on request)
- RATED VOLTAGE: 355 V
- DATA BASIS: 400 Vac (PWM > 4 kHz)
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2500 min-1
- RATED FREQUENCY: 125,0 Hz
- OUTPUT POWER: 32,5 kW (S1) / 42,3 kW (S6-40%)
- RATED TORQUE: 124 Nm (S1) / 161 Nm (S6-40%)
- RATED CURRENT: 61,4 A (S1) / 79,0 A (S6-40%)
- EFFICIENCY: 94,0 %
- MAX. SPEED AT RATED POWER: 4200 min-1
- MAX. SPEED AT MAX. TORQUE: 2300 min-1
- MAX. TORQUE: 260 Nm
- COOLANT / COOLING: liquid refrigeration; Water 20° C. +max. 20 % ethylene glycol
- VOLUMETRIC FLOW / COOLING CAPACITY: 12 L/min; Recommended min. radiator waste heat output 2,7 kW
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1 (4500 min-1 For roller bearings; may be further limited by encoder feedback or brake
- DIMENSIONS q/B/O/X/Y: 246 / 281 / 390 / 200 / 210 mm
- MOMENT OF INERTIA J: 0,0264 kgm2
- BEMF: must be less than 500 Vac; for BEMF > 500 Vac, a specific electrical protection measure against overvoltage is required
- PROTECTION DEGREE: IP54 (IP55 on request)
- RATED VOLTAGE: 340 V
- DATA BASIS: 400 Vac (PWM > 4 kHz)
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1000 min-1
- RATED FREQUENCY: 50,0 Hz
- OUTPUT POWER: 18,0 kW (S1) / 23,4 kW (S6-40%)
- RATED TORQUE: 172 Nm (S1) / 223 Nm (S6-40%)
- RATED CURRENT: 36,2 A (S1) / 46,8 A (S6-40%)
- EFFICIENCY: 91,0 %
- MAX. SPEED AT RATED POWER: 2500 min-1
- MAX. SPEED AT MAX. TORQUE: 1050 min-1
- MAX. TORQUE: 320 Nm
- COOLANT / COOLING: liquid refrigeration; Water 20° C. +max. 20 % ethylene glycol
- VOLUMETRIC FLOW / COOLING CAPACITY: 14 L/min; Recommended min. radiator waste heat output 2,3 kW
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1 (4500 min-1 For roller bearings; may be further limited by encoder feedback or brake
- DIMENSIONS q/B/O/X/Y: 296 / 331 / 440 / 200 / 210 mm
- MOMENT OF INERTIA J: 0,0320 kgm2
- BEMF: must be less than 500 Vac; for BEMF > 500 Vac, a specific electrical protection measure against overvoltage is required
- PROTECTION DEGREE: IP54 (IP55 on request)
- RATED VOLTAGE: 345 V
- DATA BASIS: 400 Vac (PWM > 4 kHz)
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1700 min-1
- RATED FREQUENCY: 85,0 Hz
- OUTPUT POWER: 29,5 kW (S1) / 38,4 kW (S6-40%)
- RATED TORQUE: 166 Nm (S1) / 215 Nm (S6-40%)
- RATED CURRENT: 58,1 A (S1) / 74,0 A (S6-40%)
- EFFICIENCY: 93,0 %
- MAX. SPEED AT RATED POWER: 3600 min-1
- MAX. SPEED AT MAX. TORQUE: 1800 min-1
- MAX. TORQUE: 320 Nm
- COOLANT / COOLING: liquid refrigeration; Water 20° C. +max. 20 % ethylene glycol
- VOLUMETRIC FLOW / COOLING CAPACITY: 14 L/min; Recommended min. radiator waste heat output 2,9 kW
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1 (4500 min-1 For roller bearings; may be further limited by encoder feedback or brake
- DIMENSIONS q/B/O/X/Y: 296 / 331 / 440 / 200 / 210 mm
- MOMENT OF INERTIA J: 0,0320 kgm2
- BEMF: must be less than 500 Vac; for BEMF > 500 Vac, a specific electrical protection measure against overvoltage is required
- PROTECTION DEGREE: IP54 (IP55 on request)
- RATED VOLTAGE: 370 V
- DATA BASIS: 400 Vac (PWM > 4 kHz)
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2500 min-1
- RATED FREQUENCY: 125,0 Hz
- OUTPUT POWER: 41,8 kW (S1) / 54,3 kW (S6-40%)
- RATED TORQUE: 160 Nm (S1) / 208 Nm (S6-40%)
- RATED CURRENT: 73,8 A (S1) / 95,0 A (S6-40%)
- EFFICIENCY: 94,0 %
- MAX. SPEED AT RATED POWER: 4000 min-1
- MAX. SPEED AT MAX. TORQUE: 2450 min-1
- MAX. TORQUE: 320 Nm
- COOLANT / COOLING: liquid refrigeration; Water 20° C. +max. 20 % ethylene glycol
- VOLUMETRIC FLOW / COOLING CAPACITY: 14 L/min; Recommended min. radiator waste heat output 3,5 kW
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1 (4500 min-1 For roller bearings; may be further limited by encoder feedback or brake
- DIMENSIONS q/B/O/X/Y: 296 / 331 / 440 / 200 / 210 mm
- MOMENT OF INERTIA J: 0,0320 kgm2
- BEMF: must be less than 500 Vac; for BEMF > 500 Vac, a specific electrical protection measure against overvoltage is required
- PROTECTION DEGREE: IP54 (IP55 on request)
- RATED VOLTAGE: 345 V
- DATA BASIS: 400 Vac (PWM > 4 kHz)
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1000 min-1
- RATED FREQUENCY: 50,0 Hz
- OUTPUT POWER: 22,0 kW (S1) / 28,6 kW (S6-40%)
- RATED TORQUE: 210 Nm (S1) / 273 Nm (S6-40%)
- RATED CURRENT: 43,6 A (S1) / 56,4 A (S6-40%)
- EFFICIENCY: 91,0 %
- MAX. SPEED AT RATED POWER: 2500 min-1
- MAX. SPEED AT MAX. TORQUE: 1050 min-1
- MAX. TORQUE: 390 Nm
- COOLANT / COOLING: liquid refrigeration; Water 20° C. +max. 20 % ethylene glycol
- VOLUMETRIC FLOW / COOLING CAPACITY: 16 L/min; Recommended min. radiator waste heat output 2,8 kW
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1 (4500 min-1 For roller bearings; may be further limited by encoder feedback or brake
- DIMENSIONS q/B/O/X/Y: 346 / 381 / 490 / 200 / 210 mm
- MOMENT OF INERTIA J: 0,0384 kgm2
- BEMF: must be less than 500 Vac; for BEMF > 500 Vac, a specific electrical protection measure against overvoltage is required
- PROTECTION DEGREE: IP54 (IP55 on request)
- RATED VOLTAGE: 360 V
- DATA BASIS: 400 Vac (PWM > 4 kHz)
- NUMBER OF POLES: 6
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 1700 min-1
- RATED FREQUENCY: 85,0 Hz
- OUTPUT POWER: 36,4 kW (S1) / 47,3 kW (S6-40%)
- RATED TORQUE: 205 Nm (S1) / 266 Nm (S6-40%)
- RATED CURRENT: 67,9 A (S1) / 87,1 A (S6-40%)
- EFFICIENCY: 93,0 %
- MAX. SPEED AT RATED POWER: 3300 min-1
- MAX. SPEED AT MAX. TORQUE: 1700 min-1
- MAX. TORQUE: 390 Nm
- COOLANT / COOLING: liquid refrigeration; Water 20° C. +max. 20 % ethylene glycol
- VOLUMETRIC FLOW / COOLING CAPACITY: 16 L/min; Recommended min. radiator waste heat output 3,6 kW
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1 (4500 min-1 For roller bearings; may be further limited by encoder feedback or brake
- DIMENSIONS q/B/O/X/Y: 346 / 381 / 490 / 200 / 210 mm
- MOMENT OF INERTIA J: 0,0384 kgm2
- BEMF: must be less than 500 Vac; for BEMF > 500 Vac, a specific electrical protection measure against overvoltage is required