KEMMERICH ELEKTROMOTOREN
- Thermal resistance max. 120° C
- New taper lock hubs for easy installation
- Allows removal and replacement without damaging the fan
High-quality plastic prevents embrittlement
-Don't slip on the wave and don't melt
the pre-drilled or undrilled bushings Must be adjusted on the building side shall be:
These fan blades are intended for assembly with the EZE-Hub®. These hubs are conically locked during assembly and enable installation and removal without damaging the fan or the shaft. The hubs (HUB) are available separately.
- Thermal resistance max. 120° C
- New taper lock hubs for easy installation
- Allows removal and replacement without damaging the fan
High-quality plastic prevents embrittlement
-Don't slip on the wave and don't melt
the pre-drilled or undrilled bushings Must be adjusted on the building side shall be:
These fan blades are intended for assembly with the EZE-Hub®. These hubs are conically locked during assembly and enable installation and removal without damaging the fan or the shaft. The hubs (HUB) are available separately.
Rotor surface: painted black
Degree of protection: IP20
Insulation class: F
Humidity class: F
Environmental protection class: H1
Mounting position: shaft horizontal or rotor below; rotor above on request
Duty type: S1
Motor protection: internal thermal protector (TW)
Cable design: variable
Protection class: rotor with basic insulation; no connection to the protective conductor
0,08-0,18 kW; 230 V +10-15%; 1,5A max. continuous current; 5 A max. start-up current
50/60 Hz; ambient temperature 0 to +45°C; Storage temperature -40 to +70°C
IP20; height 75 mm; depth 120 mm; Width 45 mm
Including installation and operating instructions
Electronic voltage control for electric motors for speed adjustment, or
Torque control on winding drives or also for electric heating systems after consultation
The voltage is over
- a setpoint potentiometer (2,5/10 kOhm)
- a voltage source 0...10 VDC
- one current input 0/4...20 mA
externally adjustable.
The limit values for minimum and maximum voltage can be set internally separately.
Suitable for 35mm DIN rail.
0,25-0,70 kW; 230 V +10-15%; 5 A max. continuous current; 15 A max. start-up current
50/60 Hz; ambient temperature 0 to +45°C; Storage temperature -40 bis +70°C;
IP20; height 75 mm; depth 120 mm; Width 45 mm
Including installation and operating instructions
Electronic voltage control for electric motors for speed adjustment
or torque control on winding drives or also for electric heating systems after consultation
The voltage is over
- a setpoint potentiometer 2,5 (10) kOhm
- a voltage source 0...10 VDC
- one current input 0...20 mA
externally adjustable.
The limit values for minimum and maximum voltage can be set internally separately.
Suitable for 35 mm DIN rail.
Pole-changing three-phase motor
| Operating data | Standard application / 4 | Standard application / 2 |
|---|---|---|
| Number of poles | 4 | 2 |
| Rated output [kW] | 2.5 | 3.3 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Δ | YY |
| Rated current [A] | 5.2 | 6.7 |
| Rated speed [min-1] | 1380 | 2785 |
| Rated torque [N·m] | 17.3 | 11.3 |
| Efficiency at rated load [%] | 77.9 | 78 |
| Power factor cos φ | 0.89 | 0.92 |
| Starting current / rated current | 4.8 | 4.9 |
| Starting torque / rated torque | 1.7 | 1.8 |
| Breakdown torque / rated torque | 2 | 2.2 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 100L |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 27 |
| Moment of inertia [kg·m²] | 0.0065 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Operating data | Standard application / 4 | Standard application / 2 |
|---|---|---|
| Number of poles | 4 | 2 |
| Rated output [kW] | 2 | 2.6 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Δ | YY |
| Rated current [A] | 4.2 | 5.3 |
| Rated speed [min-1] | 1395 | 2810 |
| Rated torque [N·m] | 13.7 | 8.8 |
| Efficiency at rated load [%] | 77.5 | 76.9 |
| Power factor cos φ | 0.88 | 0.92 |
| Starting current / rated current | 4.8 | 4.7 |
| Starting torque / rated torque | 1.6 | 1.8 |
| Breakdown torque / rated torque | 2.1 | 2.4 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 100L |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 25 |
| Moment of inertia [kg·m²] | 0.006 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Operating data | Standard application / 4 | Standard application / 2 |
|---|---|---|
| Number of poles | 4 | 2 |
| Rated output [kW] | 3.3 | 4.5 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Δ | YY |
| Rated current [A] | 6.7 | 9 |
| Rated speed [min-1] | 1435 | 2865 |
| Rated torque [N·m] | 22 | 15 |
| Efficiency at rated load [%] | 83.3 | 81.7 |
| Power factor cos φ | 0.85 | 0.88 |
| Starting current / rated current | 6.9 | 5.9 |
| Starting torque / rated torque | 2.2 | 2.2 |
| Breakdown torque / rated torque | 2.7 | 2.6 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 112M |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 33 |
| Moment of inertia [kg·m²] | 0.0119 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Operating data | Standard application / 4 | Standard application / 2 |
|---|---|---|
| Number of poles | 4 | 2 |
| Rated output [kW] | 4.7 | 5.7 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Δ | YY |
| Rated current [A] | 9.3 | 11.5 |
| Rated speed [min-1] | 1445 | 2895 |
| Rated torque [N·m] | 31.1 | 18.8 |
| Efficiency at rated load [%] | 84 | 78 |
| Power factor cos φ | 0.87 | 0.92 |
| Starting current / rated current | 5.6 | 6.1 |
| Starting torque / rated torque | 1.6 | 1.7 |
| Breakdown torque / rated torque | 2.3 | 2.4 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 132S |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 61 |
| Moment of inertia [kg·m²] | 0.029 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Operating data | Standard application / 4 | Standard application / 2 |
|---|---|---|
| Number of poles | 4 | 2 |
| Rated output [kW] | 1.4 | 2 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Δ | YY |
| Rated current [A] | 3.4 | 4.3 |
| Rated speed [min-1] | 1405 | 2750 |
| Rated torque [N·m] | 9.52 | 6.94 |
| Efficiency at rated load [%] | 73.7 | 74.3 |
| Power factor cos φ | 0.8 | 0.91 |
| Starting current / rated current | 4.4 | 4.4 |
| Starting torque / rated torque | 1.8 | 1.6 |
| Breakdown torque / rated torque | 2.2 | 2.2 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 90L |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 16.2 |
| Moment of inertia [kg·m²] | 0.0028 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Operating data | Standard application / 4 | Standard application / 2 |
|---|---|---|
| Number of poles | 4 | 2 |
| Rated output [kW] | 1.6 | 2.4 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Δ | YY |
| Rated current [A] | 3.7 | 4.5 |
| Rated speed [min-1] | 1405 | 2780 |
| Rated torque [N·m] | 10.9 | 8.24 |
| Efficiency at rated load [%] | 73.7 | 82.6 |
| Power factor cos φ | 0.85 | 0.94 |
| Starting current / rated current | 5 | 4.8 |
| Starting torque / rated torque | 1.9 | 1.4 |
| Breakdown torque / rated torque | 2.1 | 2 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 90L |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 21.5 |
| Moment of inertia [kg·m²] | 0.0148 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Operating data | Standard application / 4 | Standard application / 2 |
|---|---|---|
| Number of poles | 4 | 2 |
| Rated output [kW] | 1.1 | 1.4 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Δ | YY |
| Rated current [A] | 2.8 | 3.1 |
| Rated speed [min-1] | 1410 | 2785 |
| Rated torque [N·m] | 7.45 | 4.8 |
| Efficiency at rated load [%] | 72 | 73.1 |
| Power factor cos φ | 0.81 | 0.89 |
| Starting current / rated current | 4.4 | 4.5 |
| Starting torque / rated torque | 1.6 | 1.7 |
| Breakdown torque / rated torque | 2.1 | 2.1 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 90S |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 14 |
| Moment of inertia [kg·m²] | 0.0023 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Operating data | Fan application / 4 | Fan application / 2 |
|---|---|---|
| Number of poles | 4 | 2 |
| Rated output [kW] | 0.07 | 0.28 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | YY |
| Rated current [A] | 0.3 | 1.25 |
| Rated speed [min-1] | 1400 | 2800 |
| Rated torque [N·m] | 0.48 | 0.96 |
| Efficiency at rated load [%] | 58 | 50 |
| Power factor cos φ | 0.7 | 0.7 |
| Starting current / rated current | 2.9 | 2.7 |
| Starting torque / rated torque | 2.2 | 2.1 |
| Breakdown torque / rated torque | 1.4 | 2.3 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 71 |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 4.9 |
| Moment of inertia [kg·m²] | 0.000606 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Operating data | Fan application / 4 | Fan application / 2 |
|---|---|---|
| Number of poles | 4 | 2 |
| Rated output [kW] | 0.12 | 0.5 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | YY |
| Rated current [A] | 0.4 | 1.9 |
| Rated speed [min-1] | 1370 | 2800 |
| Rated torque [N·m] | 0.84 | 1.71 |
| Efficiency at rated load [%] | 65 | 60 |
| Power factor cos φ | 0.7 | 0.67 |
| Starting current / rated current | 2.8 | 3.5 |
| Starting torque / rated torque | 1.4 | 1.6 |
| Breakdown torque / rated torque | 1.6 | 2 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 71 |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 5.8 |
| Moment of inertia [kg·m²] | 0.00077 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
- Product type: three-phase asynchronous motor
- Rated power: 0,37 kW; 0,44 kW
- Speed: 0880 min-1; 1056 min-1
- Voltage: 230 V Δ / 400 V Y
- Frequency: 50 Hz
- Duty type: S1
- Efficiency class: IE1
- Torque: 4,02 Nm
- Standards: IEC 60034-1; IEC 60034-9
- Protection class: IP55
PLC extension card
- Type: EC-PC502-02
- Compatible with: GD350A
- Interfaces: 6DI / 2RO / 1AI / 1AO / RS485
- Product type: three-phase asynchronous motor
- Rated power: 3,00 kW
- Speed: 2880 min-1
- Voltage: 230 V Δ / 400 V Y
- Frequency: 50 Hz
- Duty type: S1
- Efficiency class: IE2
- Torque: 9,90 Nm
- Protection class: IP55
- Mounting arrangement: IM 1001 / B3
- Motor design: motor with feet
11,2 kW, S1-100%; 23,6 A; 2900 min-1
- 380-420 V; 50 Hz
- Operating position: horizontal or vertical
- max. 4500 min-1 (option max. 6000 min-1)
- suitable for variable-frequency drive operation
- Degree of protection IP66
- Insulation class H
- Optional saw-blade mount for right- or left-hand thread Ø50 g4 mm / M48
- Optional front hexagon socket for fastening
Pole-changing three-phase motor
| Operating data | Fan application / 8 | Fan application / 4 |
|---|---|---|
| Number of poles | 8 | 4 |
| Rated output [kW] | 0.9 | 3.6 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | YY |
| Rated current [A] | 2.5 | 7.8 |
| Rated speed [min-1] | 700 | 1420 |
| Rated torque [N·m] | 12.3 | 24.2 |
| Efficiency at rated load [%] | 70.9 | 78.5 |
| Power factor cos φ | 0.74 | 0.85 |
| Starting current / rated current | 3.8 | 5.8 |
| Starting torque / rated torque | 1.6 | 1.7 |
| Breakdown torque / rated torque | 2.2 | 2.5 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 112M |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 39.3 |
| Moment of inertia [kg·m²] | 0.018 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.