3AC pole-changing motors
Standard three-phase motors
Pole-changing three-phase motor
| Operating data | Fan application / 4 | Fan application / 2 |
|---|---|---|
| Number of poles | 4 | 2 |
| Rated output [kW] | 0.07 | 0.28 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | YY |
| Rated current [A] | 0.3 | 1.25 |
| Rated speed [min-1] | 1400 | 2800 |
| Rated torque [N·m] | 0.48 | 0.96 |
| Efficiency at rated load [%] | 58 | 50 |
| Power factor cos φ | 0.7 | 0.7 |
| Starting current / rated current | 2.9 | 2.7 |
| Starting torque / rated torque | 2.2 | 2.1 |
| Breakdown torque / rated torque | 1.4 | 2.3 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 71 |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 4.9 |
| Moment of inertia [kg·m²] | 0.000606 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Operating data | Standard application / 4 | Standard application / 2 |
|---|---|---|
| Number of poles | 4 | 2 |
| Rated output [kW] | 0.21 | 0.28 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Δ | YY |
| Rated current [A] | 0.95 | 1.25 |
| Rated speed [min-1] | 1400 | 2800 |
| Rated torque [N·m] | 1.43 | 0.96 |
| Efficiency at rated load [%] | 58 | 50 |
| Power factor cos φ | 0.6 | 0.7 |
| Starting current / rated current | 3.2 | 3.2 |
| Starting torque / rated torque | 1.6 | 1.6 |
| Breakdown torque / rated torque | 2 | 1.8 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 71 |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 4.9 |
| Moment of inertia [kg·m²] | 0.000606 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Operating data | Fan application / 4 | Fan application / 2 |
|---|---|---|
| Number of poles | 4 | 2 |
| Rated output [kW] | 0.12 | 0.5 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | YY |
| Rated current [A] | 0.4 | 1.9 |
| Rated speed [min-1] | 1370 | 2800 |
| Rated torque [N·m] | 0.84 | 1.71 |
| Efficiency at rated load [%] | 65 | 60 |
| Power factor cos φ | 0.7 | 0.67 |
| Starting current / rated current | 2.8 | 3.5 |
| Starting torque / rated torque | 1.4 | 1.6 |
| Breakdown torque / rated torque | 1.6 | 2 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 71 |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 5.8 |
| Moment of inertia [kg·m²] | 0.00077 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Operating data | Standard application / 4 | Standard application / 2 |
|---|---|---|
| Number of poles | 4 | 2 |
| Rated output [kW] | 0.3 | 0.45 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Δ | YY |
| Rated current [A] | 1.2 | 1.62 |
| Rated speed [min-1] | 1400 | 2820 |
| Rated torque [N·m] | 2.05 | 1.52 |
| Efficiency at rated load [%] | 68 | 60 |
| Power factor cos φ | 0.62 | 0.67 |
| Starting current / rated current | 2.7 | 4 |
| Starting torque / rated torque | 2 | 1.7 |
| Breakdown torque / rated torque | 2.1 | 1.9 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 71 |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 5.8 |
| Moment of inertia [kg·m²] | 0.00077 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Operating data | Fan application / 8 | Fan application / 4 |
|---|---|---|
| Number of poles | 8 | 4 |
| Rated output [kW] | 0.12 | 0.5 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | YY |
| Rated current [A] | 0.7 | 1.4 |
| Rated speed [min-1] | 670 | 1350 |
| Rated torque [N·m] | 1.71 | 3.54 |
| Efficiency at rated load [%] | 45 | 59 |
| Power factor cos φ | 0.6 | 0.78 |
| Starting current / rated current | 2.3 | 2.8 |
| Starting torque / rated torque | 1.5 | 1.5 |
| Breakdown torque / rated torque | 1.9 | 1.5 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 80 |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 7.3 |
| Moment of inertia [kg·m²] | 0.001693 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Operating data | Standard application / 8 | Standard application / 4 |
|---|---|---|
| Number of poles | 8 | 4 |
| Rated output [kW] | 0.22 | 0.4 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Δ | YY |
| Rated current [A] | 1.3 | 1.1 |
| Rated speed [min-1] | 670 | 1350 |
| Rated torque [N·m] | 3.14 | 2.83 |
| Efficiency at rated load [%] | 46 | 60 |
| Power factor cos φ | 0.68 | 0.87 |
| Starting current / rated current | 2 | 2.8 |
| Starting torque / rated torque | 1.5 | 1.5 |
| Breakdown torque / rated torque | 1.6 | 1.5 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 80 |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 7.3 |
| Moment of inertia [kg·m²] | 0.001693 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Number of poles | 4 | 2 |
|---|---|---|
| Rated output [kW] | 0.15 | 0.7 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | YY |
| Rated speed [min-1] | 1380 | 2730 |
| Rated current [A] | 0.5 | 2.2 |
| Rated torque [N·m] | 1.04 | 2.45 |
| Efficiency at rated load [%] | 64 | 61 |
| Power factor cos φ | 0.78 | 0.84 |
| Starting current / rated current | 3.8 | 3 |
| Starting torque / rated torque | 1.5 | 1.5 |
| Breakdown torque / rated torque | 1.6 | 1.6 |
Frame size: 80 · IP55 · F · IM B3 · 7.8 kg
Pole-changing three-phase motor
| Operating data | Standard application / 4 | Standard application / 2 |
|---|---|---|
| Number of poles | 4 | 2 |
| Rated output [kW] | 0.45 | 0.6 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Δ | YY |
| Rated current [A] | 1.5 | 1.9 |
| Rated speed [min-1] | 1360 | 2740 |
| Rated torque [N·m] | 3.16 | 2.09 |
| Efficiency at rated load [%] | 59 | 60 |
| Power factor cos φ | 0.72 | 0.83 |
| Starting current / rated current | 2.6 | 2.6 |
| Starting torque / rated torque | 1.5 | 1.5 |
| Breakdown torque / rated torque | 1.5 | 1.6 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 80 |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 7.8 |
| Moment of inertia [kg·m²] | 0.001578 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Operating data | Standard application / 6 | Standard application / 4 |
|---|---|---|
| Number of poles | 6 | 4 |
| Rated output [kW] | 0.18 | 0.55 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | Y |
| Rated current [A] | 0.9 | 1.4 |
| Rated speed [min-1] | 970 | 1380 |
| Rated torque [N·m] | 1.77 | 3.81 |
| Efficiency at rated load [%] | 50 | 68 |
| Power factor cos φ | 0.5 | 0.8 |
| Starting current / rated current | 3.0 | 3.0 |
| Starting torque / rated torque | 2.0 | 1.4 |
| Breakdown torque / rated torque | 2.6 | 1.6 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 80 |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 8.6 |
| Moment of inertia [kg·m²] | 0.00207 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
- Colour: RAL7030
Pole-changing three-phase motor
| Operating data | Fan application / 8 | Fan application / 4 |
|---|---|---|
| Number of poles | 8 | 4 |
| Rated output [kW] | 0.15 | 0.7 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | YY |
| Rated current [A] | 0.7 | 1.75 |
| Rated speed [min-1] | 660 | 1350 |
| Rated torque [N·m] | 2.17 | 4.95 |
| Efficiency at rated load [%] | 56 | 68 |
| Power factor cos φ | 0.66 | 0.84 |
| Starting current / rated current | 2.3 | 2.7 |
| Starting torque / rated torque | 1.5 | 1.5 |
| Breakdown torque / rated torque | 1.5 | 1.5 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 80 |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 8.6 |
| Moment of inertia [kg·m²] | 0.00207 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Operating data | Standard application / 8 | Standard application / 4 |
|---|---|---|
| Number of poles | 8 | 4 |
| Rated output [kW] | 0.3 | 0.55 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Δ | YY |
| Rated current [A] | 1.5 | 1.4 |
| Rated speed [min-1] | 660 | 1350 |
| Rated torque [N·m] | 4.34 | 3.89 |
| Efficiency at rated load [%] | 48 | 64 |
| Power factor cos φ | 0.64 | 0.89 |
| Starting current / rated current | 2 | 2.7 |
| Starting torque / rated torque | 1.5 | 1.5 |
| Breakdown torque / rated torque | 1.5 | 1.5 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 80 |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 8.6 |
| Moment of inertia [kg·m²] | 0.00207 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Operating data | Standard application / 4 | Standard application / 2 | Fan application / 4 | Fan application / 2 |
|---|---|---|---|---|
| Number of poles | 4 | 2 | 4 | 2 |
| Rated output [kW] | 0.75 | 0.95 | 0.25 | 1.00 |
| Voltage [V] | 400 | 400 | 400 | 400 |
| Frequency [Hz] | 50 | 50 | 50 | 50 |
| Winding connection | Δ | YY | Y | YY |
| Rated current [A] | 2.1 | 2.5 | 0.7 | 2.4 |
| Rated speed [min-1] | 1360 | 2780 | 1370 | 2780 |
| Rated torque [N·m] | 5.23 | 3.26 | 1.75 | 3.44 |
| Efficiency at rated load [%] | 69 | 70 | 50 | 70 |
| Power factor cos φ | 0.78 | 0.8 | 0.5 | 0.8 |
| Starting current / rated current | 3.1 | 3.8 | 3.0 | 3.8 |
| Starting torque / rated torque | 1.7 | 1.9 | 1.6 | 1.9 |
| Breakdown torque / rated torque | 1.8 | 2 | 1.7 | 2 |
| Duty | S1 | S1 | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 80 |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 10.2 / 10.2 |
| Moment of inertia [kg·m²] | 0.001874 / 0.001874 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Number of poles | 6 | 4 |
|---|---|---|
| Rated output [kW] | 0.25 | 0.75 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | Y |
| Rated speed [min-1] | 950 | 1410 |
| Rated current [A] | 1 | 2 |
| Rated torque [N·m] | 2.51 | 5.08 |
| Efficiency at rated load [%] | 52 | 66 |
| Power factor cos φ | 0.7 | 0.8 |
| Starting current / rated current | 2.7 | 3.3 |
| Starting torque / rated torque | 1.3 | 1.5 |
| Breakdown torque / rated torque | 1.8 | 1.9 |
Frame size: 80 · IP55 · F · IM B3 · 11 kg
Pole-changing three-phase motor
| Number of poles | 6 | 4 |
|---|---|---|
| Rated output [kW] | 0.28 | 0.8 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | Y |
| Rated speed [min-1] | 950 | 1410 |
| Rated current [A] | 0.9 | 2.1 |
| Rated torque [N·m] | 2.81 | 5.42 |
| Efficiency at rated load [%] | 62.9 | 66.9 |
| Power factor cos φ | 0.72 | 0.85 |
| Starting current / rated current | 4 | 4 |
| Starting torque / rated torque | 2.1 | 1.3 |
| Breakdown torque / rated torque | 2.3 | 1.8 |
Frame size: 90S · IP55 · F · IM B3 · 13.8 kg
Power values correspond to fan design (square torque)
attracting current 5,5/7,5 x In; starting torque 1,4/2,0 x Mn; tilting moment 1,8 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø24 x 50 mm; Heat class 155(F)
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; Moment of inertia 0,0009 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic
- Foot mounting: Removable feet (terminal box can be repositioned).
- Colour: RAL7030
Pole-changing three-phase motor
| Number of poles | 4 | 2 |
|---|---|---|
| Rated output [kW] | 0.33 | 1.4 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | YY |
| Rated speed [min-1] | 1420 | 2725 |
| Rated current [A] | 0.9 | 3.3 |
| Rated torque [N·m] | 2.2 | 4.91 |
| Efficiency at rated load [%] | 64.6 | 66.2 |
| Power factor cos φ | 0.86 | 0.93 |
| Starting current / rated current | 3.9 | 3.9 |
| Starting torque / rated torque | 1.5 | 1.6 |
| Breakdown torque / rated torque | 1.1 | 2.1 |
Frame size: 90S · IP55 · F · IM B3 · 14 kg
Pole-changing three-phase motor
| Operating data | Standard application / 4 | Standard application / 2 |
|---|---|---|
| Number of poles | 4 | 2 |
| Rated output [kW] | 1.1 | 1.4 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Δ | YY |
| Rated current [A] | 2.8 | 3.1 |
| Rated speed [min-1] | 1410 | 2785 |
| Rated torque [N·m] | 7.45 | 4.8 |
| Efficiency at rated load [%] | 72 | 73.1 |
| Power factor cos φ | 0.81 | 0.89 |
| Starting current / rated current | 4.4 | 4.5 |
| Starting torque / rated torque | 1.6 | 1.7 |
| Breakdown torque / rated torque | 2.1 | 2.1 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 90S |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 14 |
| Moment of inertia [kg·m²] | 0.0023 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Operating data | Fan application / 8 | Fan application / 4 |
|---|---|---|
| Number of poles | 8 | 4 |
| Rated output [kW] | 0.23 | 1 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | YY |
| Rated current [A] | 0.9 | 2.6 |
| Rated speed [min-1] | 700 | 1405 |
| Rated torque [N·m] | 3.14 | 6.8 |
| Efficiency at rated load [%] | 55 | 69.9 |
| Power factor cos φ | 0.66 | 0.81 |
| Starting current / rated current | 2.8 | 4.2 |
| Starting torque / rated torque | 1.6 | 1.5 |
| Breakdown torque / rated torque | 2.2 | 2.1 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 90S |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 14.7 |
| Moment of inertia [kg·m²] | 0.0025 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Operating data | Standard application / 8 | Standard application / 4 |
|---|---|---|
| Number of poles | 8 | 4 |
| Rated output [kW] | 0.37 | 0.75 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Δ | YY |
| Rated current [A] | 1.7 | 1.7 |
| Rated speed [min-1] | 705 | 1385 |
| Rated torque [N·m] | 5.01 | 5.17 |
| Efficiency at rated load [%] | 55.2 | 72.9 |
| Power factor cos φ | 0.55 | 0.87 |
| Starting current / rated current | 3 | 4.2 |
| Starting torque / rated torque | 2.1 | 1.5 |
| Breakdown torque / rated torque | 2.3 | 1.8 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 90S |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 14.9 |
| Moment of inertia [kg·m²] | 0.0025 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
attracting current 3,7/4,1 x In; starting torque 2,0/1,5 x Mn; Tilting moment 2,2/2,4 x Mn
Efficiency at nominal load [%] 63,7/66,5
Power values correspond to basic design (constant torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø19 x 40 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; moment of inertia 0,001578 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
Pole-changing three-phase motor
| Number of poles | 6 | 4 |
|---|---|---|
| Rated output [kW] | 0.63 | 0.9 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | Y |
| Rated speed [min-1] | 950 | 1425 |
| Rated current [A] | 2.2 | 2.5 |
| Rated torque [N·m] | 6.33 | 6.03 |
| Efficiency at rated load [%] | 63.7 | 66.5 |
| Power factor cos φ | 0.67 | 0.78 |
| Starting current / rated current | 3.7 | 4.1 |
| Starting torque / rated torque | 2 | 1.5 |
| Breakdown torque / rated torque | 2.2 | 2.4 |
Frame size: 90S · IP55 · F · IM B3 · 15.4 kg
Pole-changing three-phase motor
| Operating data | Standard application / 4 | Standard application / 2 |
|---|---|---|
| Number of poles | 4 | 2 |
| Rated output [kW] | 1.4 | 2 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Δ | YY |
| Rated current [A] | 3.4 | 4.3 |
| Rated speed [min-1] | 1405 | 2750 |
| Rated torque [N·m] | 9.52 | 6.94 |
| Efficiency at rated load [%] | 73.7 | 74.3 |
| Power factor cos φ | 0.8 | 0.91 |
| Starting current / rated current | 4.4 | 4.4 |
| Starting torque / rated torque | 1.8 | 1.6 |
| Breakdown torque / rated torque | 2.2 | 2.2 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 90L |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 16.2 |
| Moment of inertia [kg·m²] | 0.0028 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Number of poles | 4 | 2 |
|---|---|---|
| Rated output [kW] | 0.5 | 2 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | YY |
| Rated speed [min-1] | 1420 | 2775 |
| Rated current [A] | 1.2 | 4.3 |
| Rated torque [N·m] | 3.36 | 6.88 |
| Efficiency at rated load [%] | 73.2 | 73.9 |
| Power factor cos φ | 0.85 | 0.91 |
| Starting current / rated current | 4.5 | 4.7 |
| Starting torque / rated torque | 1.8 | 1.8 |
| Breakdown torque / rated torque | 2.9 | 2.5 |
Frame size: 90L · IP55 · F · IM B3 · 16.5 kg
Pole-changing three-phase motor
| Operating data | Standard application / 8 | Standard application / 4 |
|---|---|---|
| Number of poles | 8 | 4 |
| Rated output [kW] | 0.55 | 1 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Δ | YY |
| Rated current [A] | 2.1 | 2.2 |
| Rated speed [min-1] | 695 | 1380 |
| Rated torque [N·m] | 7.56 | 6.92 |
| Efficiency at rated load [%] | 62.1 | 74.7 |
| Power factor cos φ | 0.61 | 0.88 |
| Starting current / rated current | 3.0 | 3.9 |
| Starting torque / rated torque | 1.8 | 1.4 |
| Breakdown torque / rated torque | 2 | 2 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 90L |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 16.6 |
| Moment of inertia [kg·m²] | 0.0027 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Number of poles | 6 | 4 |
|---|---|---|
| Rated output [kW] | 0.37 | 1.1 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | Y |
| Rated speed [min-1] | 945 | 1410 |
| Rated current [A] | 1.1 | 2.9 |
| Rated torque [N·m] | 3.74 | 7.45 |
| Efficiency at rated load [%] | 59.2 | 67.7 |
| Power factor cos φ | 0.77 | 0.83 |
| Starting current / rated current | 3.5 | 4.2 |
| Starting torque / rated torque | 1.6 | 1.3 |
| Breakdown torque / rated torque | 2.8 | 2.4 |
Frame size: 90L · IP55 · F · IM B3 · 16.7 kg
Pole-changing three-phase motor
| Operating data | Standard application / 6 | Standard application / 4 |
|---|---|---|
| Number of poles | 6 | 4 |
| Rated output [kW] | 0.70 | 1.10 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | Y |
| Rated current [A] | 2.2 | 2.9 |
| Rated speed [min-1] | 935 | 1410 |
| Rated torque [N·m] | 7.15 | 7.45 |
| Efficiency at rated load [%] | 63.0 | 67.7 |
| Power factor cos φ | 0.74 | 0.83 |
| Starting current / rated current | 3.6 | 4.2 |
| Starting torque / rated torque | 1.6 | 1.4 |
| Breakdown torque / rated torque | 2.0 | 2.5 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 90L |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 16.7 |
| Moment of inertia [kg·m²] | 0.0032 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Operating data | Fan application / 8 | Fan application / 4 |
|---|---|---|
| Number of poles | 8 | 4 |
| Rated output [kW] | 0.33 | 1.3 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | YY |
| Rated current [A] | 1.1 | 3.1 |
| Rated speed [min-1] | 685 | 1400 |
| Rated torque [N·m] | 4.6 | 8.87 |
| Efficiency at rated load [%] | 61.2 | 73 |
| Power factor cos φ | 0.68 | 0.81 |
| Starting current / rated current | 2.9 | 4.7 |
| Starting torque / rated torque | 1.6 | 1.9 |
| Breakdown torque / rated torque | 2.1 | 2.7 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 90L |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 16.8 |
| Moment of inertia [kg·m²] | 0.0028 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Power values correspond to fan design (square torque)
attracting current 5/7,5 x In; starting torque 1,3/2,2 x Mn; tilting moment 2,2 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; Heat class 155(F)
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; Moment of inertia 0,0009 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic
- Foot mounting: Removable feet (terminal box can be repositioned).
- Colour: RAL7030