3AC pole-changing motors
Standard three-phase motors
0,12/0,50 kW; S1; 1370/2800 min-1; 400V Y/YY 50 Hz 3AC 0,4/1,9 A; 0,84/1,71 Nm
attracting current 2,8/3,5 x In; starting torque 1,4/1,6 x Mn; Tilting moment 1,6/2,0 x Mn
Efficiency at nominal load 65%/60%
Power values fan design (square torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø14 x 30 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6203.ZZ.C3; Camp BS: 6203.ZZ.C3; moment of inertia 0,00077 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
0,12/0,50 kW; S1; 670/1350 min-1; 400V Y/YY 50 Hz 3AC 0,70/1,40 A; 1,71/3,54 Nm
attracting current 2,3/2,8 x In; starting torque 1,5/1,5 x Mn; Tilting moment 1,9/1,5 x Mn
Efficiency at nominal load 45%/59%
Power values fan design (square torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø19 x 40 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; moment of inertia 0,001693 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010