3AC pole-changing motors
Standard three-phase motors
Power values correspond to fan design (square torque)
attracting current 5,5/7,5 x In; starting torque 1,2/1,8 x Mn; tilting moment 1,8 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; heat class 155(F); with PTC resistor PTC 150°C
Housing material up to frame size 132 aluminium, from frame size 160 grey cast iron; Colour of RAL7030
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6206.ZZ.C3; Camp BS: 6206.ZZ.C3 floating stock
half-wedge weighting species; vibration stage "A"; Fan blades plastic
- Foot mounting: Removable feet (terminal box can be repositioned).
Power values correspond to fan design (square torque)
attracting current 6,0/7,0 x In; starting torque 1,6/1,8 x Mn; tilting moment 1,8 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; Heat class 155(F)
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; Moment of inertia 0,0009 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic
- Foot mounting: Removable feet (terminal box can be repositioned).
Power values correspond to fan design (square torque)
attracting current 6,0/7,0 x In; starting torque 1,6/1,8 x Mn; tilting moment 1,8 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; Heat class 155(F)
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; Moment of inertia 0,0009 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic
- Foot mounting: Removable feet (terminal box can be repositioned).
Power values correspond to fan design (square torque)
attracting current 5/7,5 x In; starting torque 1,3/2,2 x Mn; tilting moment 2,2 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; Heat class 155(F)
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; Moment of inertia 0,0009 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic
- Foot mounting: Removable feet (terminal box can be repositioned).
Power values correspond to fan design (square torque)
attracting current 5,5/7,5 x In; starting torque 1,3/1,8 x Mn; tilting moment 1,8 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; heat class 155(F); RAL7030
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6206.ZZ.C3; Camp BS: 6206.ZZ.C3; Moment of inertia 0,0009 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic
Protective device winding PTC 150°C
- Foot mounting: Removable feet (terminal box can be repositioned).
Power values correspond to fan design (square torque)
attracting current 6,0/7,0 x In; starting torque 1,6/1,8 x Mn; tilting moment 1,8 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; Heat class 155(F)
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; Moment of inertia 0,0009 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic
- Foot mounting: Removable feet (terminal box can be repositioned).
Power values correspond to fan design (square torque)
attracting current 5/7,5 x In; starting torque 1,3/2,2 x Mn; tilting moment 2,2 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; Heat class 155(F)
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; Moment of inertia 0,0009 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic
- Foot mounting: Removable feet (terminal box can be repositioned).
Pole-changing three-phase motor
| Number of poles | 4 | 2 |
|---|---|---|
| Rated output [kW] | 0.7 | 2.6 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | YY |
| Rated speed [min-1] | 1400 | 2810 |
| Rated current [A] | 1.5 | 5.3 |
| Rated torque [N·m] | 4.8 | 8.8 |
| Efficiency at rated load [%] | 72.8 | 76.9 |
| Power factor cos φ | 0.89 | 0.92 |
| Starting current / rated current | 3.75 | 4.7 |
| Starting torque / rated torque | 1.3 | 1.8 |
| Breakdown torque / rated torque | 2.3 | 2.4 |
Frame size: 100L · IP55 · F · IM B3 · 23.1 kg
Pole-changing three-phase motor - Fan drive
| Motor frame size | 100L |
|---|---|
| Number of poles | 4/2 |
| Output power | 0.7/2.8 kW |
| Synchronous speed at 50 Hz | 1500/3000 min-1 |
| Application | Fan drive |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Y/YY - Dahlander |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.
Pole-changing three-phase motor
| Number of poles | 4 | 2 |
|---|---|---|
| Rated output [kW] | 0.85 | 3.3 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | YY |
| Rated speed [min-1] | 1380 | 2795 |
| Rated current [A] | 1.9 | 6.7 |
| Rated torque [N·m] | 5.9 | 11.3 |
| Efficiency at rated load [%] | 73.4 | 76.8 |
| Power factor cos φ | 0.9 | 0.91 |
| Starting current / rated current | 4.1 | 5.1 |
| Starting torque / rated torque | 1.3 | 1.8 |
| Breakdown torque / rated torque | 1.8 | 2.2 |
Frame size: 100L · IP55 · F · IM B3 · 24.3 kg
Pole-changing three-phase motor
| Operating data | Standard application / 4 | Standard application / 2 |
|---|---|---|
| Number of poles | 4 | 2 |
| Rated output [kW] | 2.5 | 3.3 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Δ | YY |
| Rated current [A] | 5.2 | 6.7 |
| Rated speed [min-1] | 1380 | 2785 |
| Rated torque [N·m] | 17.3 | 11.3 |
| Efficiency at rated load [%] | 77.9 | 78 |
| Power factor cos φ | 0.89 | 0.92 |
| Starting current / rated current | 4.8 | 4.9 |
| Starting torque / rated torque | 1.7 | 1.8 |
| Breakdown torque / rated torque | 2 | 2.2 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 100L |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 27 |
| Moment of inertia [kg·m²] | 0.0065 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor - Constant torque
| Motor frame size | 100L |
|---|---|
| Number of poles | 4/2 |
| Output power | 2/2.4 kW |
| Synchronous speed at 50 Hz | 1500/3000 min-1 |
| Application | Constant torque |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Δ/YY - Dahlander |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.
Pole-changing three-phase motor
| Operating data | Standard application / 4 | Standard application / 2 |
|---|---|---|
| Number of poles | 4 | 2 |
| Rated output [kW] | 2 | 2.6 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Δ | YY |
| Rated current [A] | 4.2 | 5.3 |
| Rated speed [min-1] | 1395 | 2810 |
| Rated torque [N·m] | 13.7 | 8.8 |
| Efficiency at rated load [%] | 77.5 | 76.9 |
| Power factor cos φ | 0.88 | 0.92 |
| Starting current / rated current | 4.8 | 4.7 |
| Starting torque / rated torque | 1.6 | 1.8 |
| Breakdown torque / rated torque | 2.1 | 2.4 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 100L |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 25 |
| Moment of inertia [kg·m²] | 0.006 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor
| Operating data | Fan application / 6 | Fan application / 4 |
|---|---|---|
| Number of poles | 6 | 4 |
| Rated output [kW] | 0.6 | 1.7 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | Y |
| Rated current [A] | 2 | 4.2 |
| Rated speed [min-1] | 950 | 1410 |
| Rated torque [N·m] | 6.03 | 11.5 |
| Efficiency at rated load [%] | 58.1 | 71.6 |
| Power factor cos φ | 0.76 | 0.83 |
| Starting current / rated current | 3.4 | 4.3 |
| Starting torque / rated torque | 1.3 | 1.4 |
| Breakdown torque / rated torque | 2.1 | 2.2 |
| Duty | S1 | S1 |
| Design and operating conditions | Value |
|---|---|
| Frame size | 100L |
| Degree of protection | IP55 |
| Insulation class | F |
| Ambient temperature [°C] | -15 ... +40 |
| Maximum altitude [m] | 1000 |
| Motor weight IM B3 [kg] | 23.8 |
| Moment of inertia [kg·m²] | 0.0088 |
Catalogue version: 400 V, 50 Hz. Values apply to the indicated speed stage. Other voltages, 60 Hz and special versions on request.
Pole-changing three-phase motor - Fan drive
| Motor frame size | 100L |
|---|---|
| Number of poles | 6/4 |
| Output power | 0.75/2 kW |
| Synchronous speed at 50 Hz | 1000/1500 min-1 |
| Application | Fan drive |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Y/Y - Separate windings |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.
Pole-changing three-phase motor
| Number of poles | 6 | 4 |
|---|---|---|
| Rated output [kW] | 0.75 | 2.2 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | Y |
| Rated speed [min-1] | 960 | 1415 |
| Rated current [A] | 2.2 | 5.2 |
| Rated torque [N·m] | 7.46 | 14.9 |
| Efficiency at rated load [%] | 64.9 | 73.0 |
| Power factor cos φ | 0.75 | 0.83 |
| Starting current / rated current | 4.4 | 4.6 |
| Starting torque / rated torque | 1.7 | 1.7 |
| Breakdown torque / rated torque | 2.4 | 2.2 |
Frame size: 100L · IP55 · F · IM B3 · 25.5 kg
Pole-changing three-phase motor - Constant torque
| Motor frame size | 100L |
|---|---|
| Number of poles | 6/4 |
| Output power | 0.8/1.2 kW |
| Synchronous speed at 50 Hz | 1000/1500 min-1 |
| Application | Constant torque |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Y/Y - Separate windings |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.
Pole-changing three-phase motor
| Number of poles | 6 | 4 |
|---|---|---|
| Rated output [kW] | 0.9 | 1.3 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | Y |
| Rated speed [min-1] | 960 | 1440 |
| Rated current [A] | 2.9 | 3.5 |
| Rated torque [N·m] | 8.95 | 8.62 |
| Efficiency at rated load [%] | 65.5 | 68.2 |
| Power factor cos φ | 0.7 | 0.77 |
| Starting current / rated current | 4.2 | 4.9 |
| Starting torque / rated torque | 1.7 | 1.5 |
| Breakdown torque / rated torque | 2.6 | 2.6 |
Frame size: 100L · IP55 · F · IM B3 · 21.5 kg
Pole-changing three-phase motor
| Number of poles | 6 | 4 |
|---|---|---|
| Rated output [kW] | 1.2 | 1.7 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | Y |
| Rated speed [min-1] | 960 | 1435 |
| Rated current [A] | 3.2 | 4.1 |
| Rated torque [N·m] | 11.9 | 11.3 |
| Efficiency at rated load [%] | 73 | 74 |
| Power factor cos φ | 0.74 | 0.82 |
| Starting current / rated current | 4.8 | 4.5 |
| Starting torque / rated torque | 1.8 | 1.4 |
| Breakdown torque / rated torque | 2.7 | 2.3 |
Frame size: 100L · IP55 · F · IM B3 · 26 kg
Pole-changing three-phase motor - Fan drive
| Motor frame size | 100L |
|---|---|
| Number of poles | 8/4 |
| Output power | 0.37/2.2 kW |
| Synchronous speed at 50 Hz | 750/1500 min-1 |
| Application | Fan drive |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Y/YY - Dahlander |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.