0,23/1,00 kW; S1; 700/1405 min-1; 400V Y/YY 50 Hz 3AC 0,90/2,60 A; 3,14/6,80 Nmattracting current 2,8/4,2 x In; starting torque 1,6/1,5 x Mn; Tilting moment 2,2/2,1 x MnEfficiency at nominal load 55%/70%Power values correspond to fan design (square torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø24 x 50 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6205.ZZ.C3; Camp BS: 6205.ZZ.C3; moment of inertia 0,0025 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
Safety Note!The commissioning of this incomplete machine is prohibited until it has been established that the protection and safety requirements of the Low Voltage, EMV- and Machinery Directives are met. Please note the EG installation declaration!
Please see our privacy notice