3AC pole-changing motors
Standard three-phase motors
0,60/1,70 kW; S1; 950/1410 1/min; 400V ∆/YY 50 Hz 3AC; 2,0/4,2 A; 6,3/11,5 Nm
Power values correspond to fan version D / YY, 6 clamps (square torque)
attracting current 3,4/4,3 x In; starting torque 1,3/1,4 x Mn; tilting moment 2,1/2,2 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø28 x 60 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6206.ZZ.C3; Camp BS: 6206.ZZ.C3; moment of inertia 0,0088 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010
0,90/1,70 kW; S1; 715/1415 1/min; 400V ∆/YY 50 Hz 3AC; 3,2/3,7 A; 12,0/11,5 Nm
Power values correspond to basic design (constant torque)
attracting current 4,0/5,1 x In; starting torque 2,2/1,3 x Mn; tilting moment 3,1/2,3 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø28 x 60 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6206.ZZ.C3; Camp BS: 6206.ZZ.C3; moment of inertia 0,0094 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010