1AC single-phase motors
- IP55
- 2,20 kW
- S1
- 975 1/min
- 230 V, 50 Hz ±5%
- 12,06 A
- End of shaft according to DIN/IEC Ø28 x 60 mm Heat class 155(F)
- Temperature protection: incl. 1 x PTC thermosensor
- terminal box layer at top
- Efficiency class = IE2, efficiency = 81,8 %
- Start capacitor/start capacitor μF 200μF/300V
- Operating capacitor/run capacitor μF 60μF/450V
- Approach to nominal torque / start- to rated torque 1,87
- tilt-to-rated torque / brakedown-to-rated torque 1,80
- Accommodation to rated current 5,40 / startíng- to rated current
- Capacitor circuit start-up relays/starting relays
- shaft seal (DE/NDE) 30x44x7
- Moment of inertia / moment of inertia (kg*m2) 0,019492140
- housing of die cast aluminium
- Motor feet can be screwed on or unscrewed
- AC motors are suitable for both directions of rotation
- with operating capacitor nominal power at max 40° C and up to 1000 m above NN
- dynamically balanced with half paste spring inserted
- Vibration level "N"
- Due to the start-up and operating capacitor, the 230V motor has a stronger start-up torque.
- The start-up capacitor is switched off by a centrifugal force switch when the speed is reached.
- At low load, the temperature in the engine increases sharply and this can lead to failures.
- Therefore, it is recommended that single-phase motors should not be operated at a load below 25 % of the rated load.
- IP55
- 1,50 kW
- S1
- 960 1/min
- 230 V, 50 Hz ±5%
- 8,73 A
- End of shaft according to DIN/IEC Ø28 x 60 mm Heat class 155(F)
- Temperature protection: incl. 1 x PTC- PTC resistor
- terminal box layer at top
- housing of die cast aluminium
- Motor feet can be screwed on or unscrewed
- AC motors are suitable for both directions of rotation
- with operating capacitor nominal power at max 40° C and up to 1000 m above NN
- dynamically balanced with half paste spring inserted
- Vibration level "N"
- incl. EG installation declaration with disassembly, operation & maintenance instructions
- Due to the start-up and operating capacitor, the 230V motor has a stronger start-up torque.
- The start-up capacitor is switched off by a centrifugal force switch when the speed is reached.
- At low load, the temperature in the engine increases sharply and this can lead to failures.
- Therefore, it is recommended that single-phase motors should not be operated at a load below 25 % of the rated load.
- IP55
- 1,10 kW
- S1
- 945 1/min
- 230 V, 50 Hz ±5%
- 6,73 A
- End of shaft according to DIN/IEC Ø24 x 50 mm Heat class 155(F)
- Temperature protection: incl. 1 x PTC- PTC resistor
- terminal box layer at top
- housing of die cast aluminium
- Motor feet can be screwed on or unscrewed
- AC motors are suitable for both directions of rotation
- with operating capacitor nominal power at max 40° C and up to 1000 m above NN
- dynamically balanced with half paste spring inserted
- Vibration level "N"
- incl. EG installation declaration with disassembly, operation & maintenance instructions
- Due to the start-up and operating capacitor, the 230V motor has a stronger start-up torque.
- The start-up capacitor is switched off by a centrifugal force switch when the speed is reached.
- At low load, the temperature in the engine increases sharply and this can lead to failures.
- Therefore, it is recommended that single-phase motors should not be operated at a load below 25 % of the rated load.
- IP55
- 0,55 kW
- S1
- 935 1/min
- 230 V, 50 Hz ±5%
- 3,47 A
- End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
- Temperature protection: incl. 1 x PTC- PTC resistor
- terminal box layer at top
- housing of die cast aluminium
- Motor feet can be screwed on or unscrewed
- AC motors are suitable for both directions of rotation
- with operating capacitor nominal power at max 40° C and up to 1000 m above NN
- dynamically balanced with half paste spring inserted
- Vibration level "N"
- incl. EG installation declaration with disassembly, operation & maintenance instructions
- Due to the start-up and operating capacitor, the 230V motor has a stronger start-up torque.
- The start-up capacitor is switched off by a centrifugal force switch when the speed is reached.
- At low load, the temperature in the engine increases sharply and this can lead to failures.
- Therefore, it is recommended that single-phase motors should not be operated at a load below 25 % of the rated load.
- IP55
- 0,37 kW
- S1
- 935 1/min
- 230 V, 50 Hz ±5%
- 2,48 A
- End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
- Temperature protection: incl. 1 x PTC- PTC resistor
- terminal box layer at top
- housing of die cast aluminium
- Motor feet can be screwed on or unscrewed
- AC motors are suitable for both directions of rotation
- with operating capacitor nominal power at max 40° C and up to 1000 m above NN
- dynamically balanced with half paste spring inserted
- Vibration level "N"
- incl. EG installation declaration with disassembly, operation & maintenance instructions
- Due to the start-up and operating capacitor, the 230V motor has a stronger start-up torque.
- The start-up capacitor is switched off by a centrifugal force switch when the speed is reached.
- At low load, the temperature in the engine increases sharply and this can lead to failures.
- Therefore, it is recommended that single-phase motors should not be operated at a load below 25 % of the rated load.
- IP55
- 0,25 kW
- S1
- 930 1/min
- 230 V, 50 Hz ±5%
- 1,86 A
- End of shaft according to DIN/IEC Ø14 x 30 mm Heat class 155(F)
- Temperature protection: incl. 1 x PTC- PTC resistor
- terminal box layer at top
- housing of die cast aluminium
- Motor feet can be screwed on or unscrewed
- AC motors are suitable for both directions of rotation
- with operating capacitor nominal power at max 40° C and up to 1000 m above NN
- dynamically balanced with half paste spring inserted
- Vibration level "N"
- incl. EG installation declaration with disassembly, operation & maintenance instructions
- Due to the start-up and operating capacitor, the 230V motor has a stronger start-up torque.
- The start-up capacitor is switched off by a centrifugal force switch when the speed is reached.
- At low load, the temperature in the engine increases sharply and this can lead to failures.
- Therefore, it is recommended that single-phase motors should not be operated at a load below 25 % of the rated load.
- IP55
- 0,18 kW
- S1
- 930 1/min
- 230 V, 50 Hz ±5%
- 1,34 A
- End of shaft according to DIN/IEC Ø14 x 30 mm Heat class 155(F)
- Temperature protection: incl. 1 x PTC- PTC resistor
- terminal box layer at top
- housing of die cast aluminium
- Motor feet can be screwed on or unscrewed
- AC motors are suitable for both directions of rotation
- with operating capacitor nominal power at max 40° C and up to 1000 m above NN
- dynamically balanced with half paste spring inserted
- Vibration level "N"
- incl. EG installation declaration with disassembly, operation & maintenance instructions
- Due to the start-up and operating capacitor, the 230V motor has a stronger start-up torque.
- The start-up capacitor is switched off by a centrifugal force switch when the speed is reached.
- At low load, the temperature in the engine increases sharply and this can lead to failures.
- Therefore, it is recommended that single-phase motors should not be operated at a load below 25 % of the rated load.
- IP55
- 0,12 kW
- S1
- 930 1/min
- 230 V, 50 Hz ±5%
- 0,9 A
- End of shaft according to DIN/IEC Ø11 x 23 mm Heat class 155(F)
- Temperature protection: incl. 1 x PTC- PTC resistor
- terminal box layer at top
- housing of die cast aluminium
- Motor feet can be screwed on or unscrewed
- AC motors are suitable for both directions of rotation
- with operating capacitor nominal power at max 40° C and up to 1000 m above NN
- dynamically balanced with half paste spring inserted
- Vibration level "N"
- incl. EG installation declaration with disassembly, operation & maintenance instructions
- Due to the start-up and operating capacitor, the 230V motor has a stronger start-up torque.
- The start-up capacitor is switched off by a centrifugal force switch when the speed is reached.
- At low load, the temperature in the engine increases sharply and this can lead to failures.
- Therefore, it is recommended that single-phase motors should not be operated at a load below 25 % of the rated load.
End of shaft according to DIN/IEC Ø28 x 60 mm Heat class 155(F)
with operating capacitor and start-up console Ma/Mn 2,50
Rated power at max. 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
End of shaft according to DIN/IEC Ø28 x 60 mm Heat class 155(F)
with operating capacitor and start-up console Ma/Mn 2,50
Maximum rated power at maximum 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions