1AC single-phase motors
Items 1 - 7 of 7
IP55; 0,25 kW; S1; 2800/min; 230 V, 50 Hz ±5%; 1,91 A
End of shaft according to DIN/IEC Ø11 x 23 mm Heat class 155(F)
with operating capacitor nominal power at max 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
End of shaft according to DIN/IEC Ø11 x 23 mm Heat class 155(F)
with operating capacitor nominal power at max 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
- Rated output P2 [kW]: 0.25
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Rated speed [min−1]: 2760
- Rated current [A]: 1.90
- Rated torque [N·m]: 0.87
- Efficiency [%]: 64
- Power factor cos φ: 0.92
- Starting current / rated current: 2.2
- Starting torque / rated torque: 0.90
- Breakdown torque / rated torque: 2.0
- Moment of inertia J [kg·m²]: 0.000310
- Run capacitor [µF]: 10
- Frame size: 63
- Number of poles: 2
- Degree of protection: IP55
- Insulation class: F
- Motor weight, base design [kg]: 4.8
- Ambient temperature: -15…+40 °C
- Colour: RAL 5010
- Design standard: IEC 60034-1 / PN-EN 60034-1
- Mounting arrangement: Variants as selected
- Capacitor rated voltage [V]: 450
- Shaft end D × E [mm]: 11j6 × 23
- Bearings: 6202 2Z
- With run capacitor
- Further dimensions [mm]: D = 11j6; E = 23; F = 4h9; GA = 12.5; DW = M20; AC = 126; AD = 74; BL = 11; L = 225; LC = 257
- Foot dimensions [mm]: A = 100; B = 80; C = 40; CA = 94; H = 63 (−0.5); K = 7; K1 = 10; AA = 36; AB = 124; BB = 106; HA = 8.5; HD = 165
- Flange dimensions [mm] B5: R = 0; HB = 102; P = 140; M = 115; N = 95j6; S = 10; LA = 9; T = 3
- Flange dimensions [mm] B14A: R = 0; HB = 102; P = 90; M = 75; N = 60j6; S = M5; LE = 9.5; T = 2.5
- Flange dimensions [mm] B14B: R = 0; HB = 102; P = 120; M = 100; N = 80j6; S = M6; LE = 14; T = 3
IP55; 0,25 kW; S1; 1370 1/min; 230 V, 50 Hz ±5%; 1,99 A
End of shaft according to DIN/IEC Ø14 x 30 mm Heat class 155(F)
with operating capacitor and starting capacitor Ma/Mn 2,50
Maximum rated power at maximum 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
End of shaft according to DIN/IEC Ø14 x 30 mm Heat class 155(F)
with operating capacitor and starting capacitor Ma/Mn 2,50
Maximum rated power at maximum 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
- Rated output P2 [kW]: 0.25
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Specified speed [min−1]: 1370
- Rated current [A]: 1.99
- Starting torque / rated torque: 2.50
- Frame size: 71
- Number of poles: 4
- Degree of protection: IP55
- Insulation class: F
- Ambient temperature: ≤ +40 °C
- Installation altitude up to [m]: 1000
- Vibration grade: N
- Mounting arrangement: Variants as selected
- Shaft end D × E [mm]: 14 × 30
- With run and start capacitors
- Dynamically balanced with half key
- Shaft end including key
- Removable feet; rotatable terminal box
IP55; 0,25 kW; S1; 1370 1/min; 230 V, 50 Hz ±5%; 2,2 A
End of shaft according to DIN/IEC Ø14 x 30 mm Heat class 155(F)
with operating capacitor nominal power at max 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
End of shaft according to DIN/IEC Ø14 x 30 mm Heat class 155(F)
with operating capacitor nominal power at max 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
- Rated output P2 [kW]: 0.25
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Rated speed [min−1]: 1340
- Rated current [A]: 2.5
- Rated torque [N·m]: 1.78
- Efficiency [%]: 56
- Power factor cos φ: 0.80
- Starting current / rated current: 2.0
- Starting torque / rated torque: 1.00
- Breakdown torque / rated torque: 1.70
- Moment of inertia J [kg·m²]: 0.00085
- Run capacitor [µF]: 10
- Frame size: 71
- Number of poles: 4
- Degree of protection: IP55
- Insulation class: F
- Motor weight, base design [kg]: 6.3
- Ambient temperature: -15…+40 °C
- Colour: RAL 5010
- Design standard: IEC 60034-1 / PN-EN 60034-1
- Mounting arrangement: Variants as selected
- Capacitor rated voltage [V]: 450
- Shaft end D × E [mm]: 14j6 × 30
- Bearings: 6203 2Z
- With run capacitor
- Further dimensions [mm]: D = 14j6; E = 30; F = 5h9; GA = 16; DW = M20; AC = 141; AD = 90; BL = 12; L = 245; LC = 283
- Foot dimensions [mm]: A = 112; B = 90; C = 45; CA = 88; H = 71 (−0.5); K = 7; K1 = 10; AA = 45; AB = 142; BB = 116; HA = 8; HD = 182
- Flange dimensions [mm] B5: R = 0; HB = 111; P = 160; M = 130; N = 110j6; S = 10; LA = 9; T = 3.5
- Flange dimensions [mm] B14A: R = 0; HB = 111; P = 105; M = 85; N = 70j6; S = M6; LE = 12; T = 2.5
- Flange dimensions [mm] B14B: R = 0; HB = 111; P = 140; M = 115; N = 95j6; S = M8; LE = 14; T = 3
- IP55
- 0,25 kW
- S1
- 930 1/min
- 230 V, 50 Hz ±5%
- 1,86 A
- End of shaft according to DIN/IEC Ø14 x 30 mm Heat class 155(F)
- Temperature protection: incl. 1 x PTC- PTC resistor
- terminal box layer at top
- housing of die cast aluminium
- Motor feet can be screwed on or unscrewed
- AC motors are suitable for both directions of rotation
- with operating capacitor nominal power at max 40° C and up to 1000 m above NN
- dynamically balanced with half paste spring inserted
- Vibration level "N"
- incl. EG installation declaration with disassembly, operation & maintenance instructions
- Due to the start-up and operating capacitor, the 230V motor has a stronger start-up torque.
- The start-up capacitor is switched off by a centrifugal force switch when the speed is reached.
- At low load, the temperature in the engine increases sharply and this can lead to failures.
- Therefore, it is recommended that single-phase motors should not be operated at a load below 25 % of the rated load.
Items 1 - 7 of 7