- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: -
- Time Rating: Continuous
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - Overheat Protective Device Type: Thermal protector
- Mass: 5.0 kg
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 9
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 167 r/min
Three-Phase 380 VAC / 60 Hz: 200 r/min
Three-Phase 400 VAC / 50 Hz: 167 r/min
Three-Phase 400 VAC / 60 Hz: 200 r/min
Three-Phase 415 VAC / 50 Hz: 167 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 9.7 N·m
Three-Phase 380 VAC / 60 Hz: 8.1 N·m
Three-Phase 400 VAC / 50 Hz: 9.7 N·m
Three-Phase 400 VAC / 60 Hz: 8.1 N·m
Three-Phase 415 VAC / 50 Hz: 9.7 N·m - Permissible Inertia J: 162×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 9
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 167 r/min
Three-Phase 380 VAC / 60 Hz: 200 r/min
Three-Phase 400 VAC / 50 Hz: 167 r/min
Three-Phase 400 VAC / 60 Hz: 200 r/min
Three-Phase 415 VAC / 50 Hz: 167 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 9.7 N·m
Three-Phase 380 VAC / 60 Hz: 8.1 N·m
Three-Phase 400 VAC / 50 Hz: 9.7 N·m
Three-Phase 400 VAC / 60 Hz: 8.1 N·m
Three-Phase 415 VAC / 50 Hz: 9.7 N·m - Permissible Inertia J: 162×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 90
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 17 r/min
Three-Phase 380 VAC / 60 Hz: 20 r/min
Three-Phase 400 VAC / 50 Hz: 17 r/min
Three-Phase 400 VAC / 60 Hz: 20 r/min
Three-Phase 415 VAC / 50 Hz: 17 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 51.5 N·m
Three-Phase 380 VAC / 60 Hz: 51.5 N·m
Three-Phase 400 VAC / 50 Hz: 51.5 N·m
Three-Phase 400 VAC / 60 Hz: 51.5 N·m
Three-Phase 415 VAC / 50 Hz: 51.5 N·m - Permissible Inertia J: 5000×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 90
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 17 r/min
Three-Phase 380 VAC / 60 Hz: 20 r/min
Three-Phase 400 VAC / 50 Hz: 17 r/min
Three-Phase 400 VAC / 60 Hz: 20 r/min
Three-Phase 415 VAC / 50 Hz: 17 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 51.5 N·m
Three-Phase 380 VAC / 60 Hz: 51.5 N·m
Three-Phase 400 VAC / 50 Hz: 51.5 N·m
Three-Phase 400 VAC / 60 Hz: 51.5 N·m
Three-Phase 415 VAC / 50 Hz: 51.5 N·m - Permissible Inertia J: 5000×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 90
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 17 r/min
Three-Phase 380 VAC / 60 Hz: 20 r/min
Three-Phase 400 VAC / 50 Hz: 17 r/min
Three-Phase 400 VAC / 60 Hz: 20 r/min
Three-Phase 415 VAC / 50 Hz: 17 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
Three-Phase 380 VAC / 60 Hz: 40 N·m
Three-Phase 400 VAC / 50 Hz: 40 N·m
Three-Phase 400 VAC / 60 Hz: 40 N·m
Three-Phase 415 VAC / 50 Hz: 40 N·m - Permissible Inertia J: 5000×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 8.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 9
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 167 r/min
Three-Phase 380 VAC / 60 Hz: 200 r/min
Three-Phase 400 VAC / 50 Hz: 167 r/min
Three-Phase 400 VAC / 60 Hz: 200 r/min
Three-Phase 415 VAC / 50 Hz: 167 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 11.9 N·m
Three-Phase 380 VAC / 60 Hz: 10 N·m
Three-Phase 400 VAC / 50 Hz: 11.9 N·m
Three-Phase 400 VAC / 60 Hz: 10 N·m
Three-Phase 415 VAC / 50 Hz: 11.9 N·m - Permissible Inertia J: 162×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 8.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 75
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 20 r/min
Three-Phase 380 VAC / 60 Hz: 24 r/min
Three-Phase 400 VAC / 50 Hz: 20 r/min
Three-Phase 400 VAC / 60 Hz: 24 r/min
Three-Phase 415 VAC / 50 Hz: 20 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 47 N·m
Three-Phase 380 VAC / 60 Hz: 47 N·m
Three-Phase 400 VAC / 50 Hz: 47 N·m
Three-Phase 400 VAC / 60 Hz: 47 N·m
Three-Phase 415 VAC / 50 Hz: 47 N·m - Permissible Inertia J: 5000×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 75
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 20 r/min
Three-Phase 380 VAC / 60 Hz: 24 r/min
Three-Phase 400 VAC / 50 Hz: 20 r/min
Three-Phase 400 VAC / 60 Hz: 24 r/min
Three-Phase 415 VAC / 50 Hz: 20 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 47 N·m
Three-Phase 380 VAC / 60 Hz: 47 N·m
Three-Phase 400 VAC / 50 Hz: 47 N·m
Three-Phase 400 VAC / 60 Hz: 47 N·m
Three-Phase 415 VAC / 50 Hz: 47 N·m - Permissible Inertia J: 5000×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 75
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 20 r/min
Three-Phase 380 VAC / 60 Hz: 24 r/min
Three-Phase 400 VAC / 50 Hz: 20 r/min
Three-Phase 400 VAC / 60 Hz: 24 r/min
Three-Phase 415 VAC / 50 Hz: 20 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
Three-Phase 380 VAC / 60 Hz: 40 N·m
Three-Phase 400 VAC / 50 Hz: 40 N·m
Three-Phase 400 VAC / 60 Hz: 40 N·m
Three-Phase 415 VAC / 50 Hz: 40 N·m - Permissible Inertia J: 5000×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 8.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 7.5
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 200 r/min
Three-Phase 380 VAC / 60 Hz: 240 r/min
Three-Phase 400 VAC / 50 Hz: 200 r/min
Three-Phase 400 VAC / 60 Hz: 240 r/min
Three-Phase 415 VAC / 50 Hz: 200 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 8 N·m
Three-Phase 380 VAC / 60 Hz: 6.8 N·m
Three-Phase 400 VAC / 50 Hz: 8 N·m
Three-Phase 400 VAC / 60 Hz: 6.8 N·m
Three-Phase 415 VAC / 50 Hz: 8 N·m - Permissible Inertia J: 112×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 7.5
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 200 r/min
Three-Phase 380 VAC / 60 Hz: 240 r/min
Three-Phase 400 VAC / 50 Hz: 200 r/min
Three-Phase 400 VAC / 60 Hz: 240 r/min
Three-Phase 415 VAC / 50 Hz: 200 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 8 N·m
Three-Phase 380 VAC / 60 Hz: 6.8 N·m
Three-Phase 400 VAC / 50 Hz: 8 N·m
Three-Phase 400 VAC / 60 Hz: 6.8 N·m
Three-Phase 415 VAC / 50 Hz: 8 N·m - Permissible Inertia J: 112×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 7.5
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 200 r/min
Three-Phase 380 VAC / 60 Hz: 240 r/min
Three-Phase 400 VAC / 50 Hz: 200 r/min
Three-Phase 400 VAC / 60 Hz: 240 r/min
Three-Phase 415 VAC / 50 Hz: 200 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 9.9 N·m
Three-Phase 380 VAC / 60 Hz: 8.4 N·m
Three-Phase 400 VAC / 50 Hz: 9.9 N·m
Three-Phase 400 VAC / 60 Hz: 8.4 N·m
Three-Phase 415 VAC / 50 Hz: 9.9 N·m - Permissible Inertia J: 112×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 8.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 6
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 250 r/min
Three-Phase 380 VAC / 60 Hz: 300 r/min
Three-Phase 400 VAC / 50 Hz: 250 r/min
Three-Phase 400 VAC / 60 Hz: 300 r/min
Three-Phase 415 VAC / 50 Hz: 250 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 6.4 N·m
Three-Phase 380 VAC / 60 Hz: 5.4 N·m
Three-Phase 400 VAC / 50 Hz: 6.4 N·m
Three-Phase 400 VAC / 60 Hz: 5.4 N·m
Three-Phase 415 VAC / 50 Hz: 6.4 N·m - Permissible Inertia J: 72×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 6
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 250 r/min
Three-Phase 380 VAC / 60 Hz: 300 r/min
Three-Phase 400 VAC / 50 Hz: 250 r/min
Three-Phase 400 VAC / 60 Hz: 300 r/min
Three-Phase 415 VAC / 50 Hz: 250 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 6.4 N·m
Three-Phase 380 VAC / 60 Hz: 5.4 N·m
Three-Phase 400 VAC / 50 Hz: 6.4 N·m
Three-Phase 400 VAC / 60 Hz: 5.4 N·m
Three-Phase 415 VAC / 50 Hz: 6.4 N·m - Permissible Inertia J: 72×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 60
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 25 r/min
Three-Phase 380 VAC / 60 Hz: 30 r/min
Three-Phase 400 VAC / 50 Hz: 25 r/min
Three-Phase 400 VAC / 60 Hz: 30 r/min
Three-Phase 415 VAC / 50 Hz: 25 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 43 N·m
Three-Phase 380 VAC / 60 Hz: 43 N·m
Three-Phase 400 VAC / 50 Hz: 43 N·m
Three-Phase 400 VAC / 60 Hz: 43 N·m
Three-Phase 415 VAC / 50 Hz: 43 N·m - Permissible Inertia J: 5000×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 60
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 25 r/min
Three-Phase 380 VAC / 60 Hz: 30 r/min
Three-Phase 400 VAC / 50 Hz: 25 r/min
Three-Phase 400 VAC / 60 Hz: 30 r/min
Three-Phase 415 VAC / 50 Hz: 25 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 43 N·m
Three-Phase 380 VAC / 60 Hz: 43 N·m
Three-Phase 400 VAC / 50 Hz: 43 N·m
Three-Phase 400 VAC / 60 Hz: 43 N·m
Three-Phase 415 VAC / 50 Hz: 43 N·m - Permissible Inertia J: 5000×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 60
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 25 r/min
Three-Phase 380 VAC / 60 Hz: 30 r/min
Three-Phase 400 VAC / 50 Hz: 25 r/min
Three-Phase 400 VAC / 60 Hz: 30 r/min
Three-Phase 415 VAC / 50 Hz: 25 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
Three-Phase 380 VAC / 60 Hz: 40 N·m
Three-Phase 400 VAC / 50 Hz: 40 N·m
Three-Phase 400 VAC / 60 Hz: 40 N·m
Three-Phase 415 VAC / 50 Hz: 40 N·m - Permissible Inertia J: 5000×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 8.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 6
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 250 r/min
Three-Phase 380 VAC / 60 Hz: 300 r/min
Three-Phase 400 VAC / 50 Hz: 250 r/min
Three-Phase 400 VAC / 60 Hz: 300 r/min
Three-Phase 415 VAC / 50 Hz: 250 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 7.9 N·m
Three-Phase 380 VAC / 60 Hz: 6.7 N·m
Three-Phase 400 VAC / 50 Hz: 7.9 N·m
Three-Phase 400 VAC / 60 Hz: 6.7 N·m
Three-Phase 415 VAC / 50 Hz: 7.9 N·m - Permissible Inertia J: 72×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 8.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 5
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 300 r/min
Three-Phase 380 VAC / 60 Hz: 360 r/min
Three-Phase 400 VAC / 50 Hz: 300 r/min
Three-Phase 400 VAC / 60 Hz: 360 r/min
Three-Phase 415 VAC / 50 Hz: 300 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 5.4 N·m
Three-Phase 380 VAC / 60 Hz: 4.5 N·m
Three-Phase 400 VAC / 50 Hz: 5.4 N·m
Three-Phase 400 VAC / 60 Hz: 4.5 N·m
Three-Phase 415 VAC / 50 Hz: 5.4 N·m - Permissible Inertia J: 50×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 5
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 300 r/min
Three-Phase 380 VAC / 60 Hz: 360 r/min
Three-Phase 400 VAC / 50 Hz: 300 r/min
Three-Phase 400 VAC / 60 Hz: 360 r/min
Three-Phase 415 VAC / 50 Hz: 300 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 5.4 N·m
Three-Phase 380 VAC / 60 Hz: 4.5 N·m
Three-Phase 400 VAC / 50 Hz: 5.4 N·m
Three-Phase 400 VAC / 60 Hz: 4.5 N·m
Three-Phase 415 VAC / 50 Hz: 5.4 N·m - Permissible Inertia J: 50×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 50
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 30 r/min
Three-Phase 380 VAC / 60 Hz: 36 r/min
Three-Phase 400 VAC / 50 Hz: 30 r/min
Three-Phase 400 VAC / 60 Hz: 36 r/min
Three-Phase 415 VAC / 50 Hz: 30 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
Three-Phase 380 VAC / 60 Hz: 40 N·m
Three-Phase 400 VAC / 50 Hz: 40 N·m
Three-Phase 400 VAC / 60 Hz: 40 N·m
Three-Phase 415 VAC / 50 Hz: 40 N·m - Permissible Inertia J: 5000×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 50
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 30 r/min
Three-Phase 380 VAC / 60 Hz: 36 r/min
Three-Phase 400 VAC / 50 Hz: 30 r/min
Three-Phase 400 VAC / 60 Hz: 36 r/min
Three-Phase 415 VAC / 50 Hz: 30 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
Three-Phase 380 VAC / 60 Hz: 40 N·m
Three-Phase 400 VAC / 50 Hz: 40 N·m
Three-Phase 400 VAC / 60 Hz: 40 N·m
Three-Phase 415 VAC / 50 Hz: 40 N·m - Permissible Inertia J: 5000×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 50
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 30 r/min
Three-Phase 380 VAC / 60 Hz: 36 r/min
Three-Phase 400 VAC / 50 Hz: 30 r/min
Three-Phase 400 VAC / 60 Hz: 36 r/min
Three-Phase 415 VAC / 50 Hz: 30 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
Three-Phase 380 VAC / 60 Hz: 40 N·m
Three-Phase 400 VAC / 50 Hz: 40 N·m
Three-Phase 400 VAC / 60 Hz: 40 N·m
Three-Phase 415 VAC / 50 Hz: 40 N·m - Permissible Inertia J: 5000×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 8.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 5
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 300 r/min
Three-Phase 380 VAC / 60 Hz: 360 r/min
Three-Phase 400 VAC / 50 Hz: 300 r/min
Three-Phase 400 VAC / 60 Hz: 360 r/min
Three-Phase 415 VAC / 50 Hz: 300 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 6.6 N·m
Three-Phase 380 VAC / 60 Hz: 5.6 N·m
Three-Phase 400 VAC / 50 Hz: 6.6 N·m
Three-Phase 400 VAC / 60 Hz: 5.6 N·m
Three-Phase 415 VAC / 50 Hz: 6.6 N·m - Permissible Inertia J: 50×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 8.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 36
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 42 r/min
Three-Phase 380 VAC / 60 Hz: 50 r/min
Three-Phase 400 VAC / 50 Hz: 42 r/min
Three-Phase 400 VAC / 60 Hz: 50 r/min
Three-Phase 415 VAC / 50 Hz: 42 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 36 N·m
Three-Phase 380 VAC / 60 Hz: 32.6 N·m
Three-Phase 400 VAC / 50 Hz: 36 N·m
Three-Phase 400 VAC / 60 Hz: 32.6 N·m
Three-Phase 415 VAC / 50 Hz: 36 N·m - Permissible Inertia J: 2592×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 36
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 42 r/min
Three-Phase 380 VAC / 60 Hz: 50 r/min
Three-Phase 400 VAC / 50 Hz: 42 r/min
Three-Phase 400 VAC / 60 Hz: 50 r/min
Three-Phase 415 VAC / 50 Hz: 42 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 36 N·m
Three-Phase 380 VAC / 60 Hz: 32.6 N·m
Three-Phase 400 VAC / 50 Hz: 36 N·m
Three-Phase 400 VAC / 60 Hz: 32.6 N·m
Three-Phase 415 VAC / 50 Hz: 36 N·m - Permissible Inertia J: 2592×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 36
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 42 r/min
Three-Phase 380 VAC / 60 Hz: 50 r/min
Three-Phase 400 VAC / 50 Hz: 42 r/min
Three-Phase 400 VAC / 60 Hz: 50 r/min
Three-Phase 415 VAC / 50 Hz: 42 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
Three-Phase 380 VAC / 60 Hz: 38.4 N·m
Three-Phase 400 VAC / 50 Hz: 40 N·m
Three-Phase 400 VAC / 60 Hz: 38.4 N·m
Three-Phase 415 VAC / 50 Hz: 40 N·m - Permissible Inertia J: 2592×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 8.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 30
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 50 r/min
Three-Phase 380 VAC / 60 Hz: 60 r/min
Three-Phase 400 VAC / 50 Hz: 50 r/min
Three-Phase 400 VAC / 60 Hz: 60 r/min
Three-Phase 415 VAC / 50 Hz: 50 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 32.2 N·m
Three-Phase 380 VAC / 60 Hz: 27.2 N·m
Three-Phase 400 VAC / 50 Hz: 32.2 N·m
Three-Phase 400 VAC / 60 Hz: 27.2 N·m
Three-Phase 415 VAC / 50 Hz: 32.2 N·m - Permissible Inertia J: 1800×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.