• Description of Specification Items
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 18
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 83 r/min
Three-Phase 380 VAC / 60 Hz: 100 r/min
Three-Phase 400 VAC / 50 Hz: 83 r/min
Three-Phase 400 VAC / 60 Hz: 100 r/min
Three-Phase 415 VAC / 50 Hz: 83 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 22.8 N·m
Three-Phase 380 VAC / 60 Hz: 19.2 N·m
Three-Phase 400 VAC / 50 Hz: 22.8 N·m
Three-Phase 400 VAC / 60 Hz: 19.2 N·m
Three-Phase 415 VAC / 50 Hz: 22.8 N·m - Permissible Inertia J: 648×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 8.0 kg (With gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 25
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 60 r/min
Three-Phase 380 VAC / 60 Hz: 72 r/min
Three-Phase 400 VAC / 50 Hz: 60 r/min
Three-Phase 400 VAC / 60 Hz: 72 r/min
Three-Phase 415 VAC / 50 Hz: 60 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 31.6 N·m
Three-Phase 380 VAC / 60 Hz: 26.7 N·m
Three-Phase 400 VAC / 50 Hz: 31.6 N·m
Three-Phase 400 VAC / 60 Hz: 26.7 N·m
Three-Phase 415 VAC / 50 Hz: 31.6 N·m - Permissible Inertia J: 1250×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 8.0 kg (With gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 30
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 50 r/min
Three-Phase 380 VAC / 60 Hz: 60 r/min
Three-Phase 400 VAC / 50 Hz: 50 r/min
Three-Phase 400 VAC / 60 Hz: 60 r/min
Three-Phase 415 VAC / 50 Hz: 50 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 37.9 N·m
Three-Phase 380 VAC / 60 Hz: 32 N·m
Three-Phase 400 VAC / 50 Hz: 37.9 N·m
Three-Phase 400 VAC / 60 Hz: 32 N·m
Three-Phase 415 VAC / 50 Hz: 37.9 N·m - Permissible Inertia J: 1800×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 8.0 kg (With gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 36
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 42 r/min
Three-Phase 380 VAC / 60 Hz: 50 r/min
Three-Phase 400 VAC / 50 Hz: 42 r/min
Three-Phase 400 VAC / 60 Hz: 50 r/min
Three-Phase 415 VAC / 50 Hz: 42 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
Three-Phase 380 VAC / 60 Hz: 38.4 N·m
Three-Phase 400 VAC / 50 Hz: 40 N·m
Three-Phase 400 VAC / 60 Hz: 38.4 N·m
Three-Phase 415 VAC / 50 Hz: 40 N·m - Permissible Inertia J: 2592×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 8.0 kg (With gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 100
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 15 r/min
Three-Phase 380 VAC / 60 Hz: 18 r/min
Three-Phase 400 VAC / 50 Hz: 15 r/min
Three-Phase 400 VAC / 60 Hz: 18 r/min
Three-Phase 415 VAC / 50 Hz: 15 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
Three-Phase 380 VAC / 60 Hz: 40 N·m
Three-Phase 400 VAC / 50 Hz: 40 N·m
Three-Phase 400 VAC / 60 Hz: 40 N·m
Three-Phase 415 VAC / 50 Hz: 40 N·m - Permissible Inertia J: 5000×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 8.0 kg (With gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 120
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 12.5 r/min
Three-Phase 380 VAC / 60 Hz: 15 r/min
Three-Phase 400 VAC / 50 Hz: 12.5 r/min
Three-Phase 400 VAC / 60 Hz: 15 r/min
Three-Phase 415 VAC / 50 Hz: 12.5 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
Three-Phase 380 VAC / 60 Hz: 40 N·m
Three-Phase 400 VAC / 50 Hz: 40 N·m
Three-Phase 400 VAC / 60 Hz: 40 N·m
Three-Phase 415 VAC / 50 Hz: 40 N·m - Permissible Inertia J: 5000×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 8.0 kg (With gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 150
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 10 r/min
Three-Phase 380 VAC / 60 Hz: 12 r/min
Three-Phase 400 VAC / 50 Hz: 10 r/min
Three-Phase 400 VAC / 60 Hz: 12 r/min
Three-Phase 415 VAC / 50 Hz: 10 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
Three-Phase 380 VAC / 60 Hz: 40 N·m
Three-Phase 400 VAC / 50 Hz: 40 N·m
Three-Phase 400 VAC / 60 Hz: 40 N·m
Three-Phase 415 VAC / 50 Hz: 40 N·m - Permissible Inertia J: 5000×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 8.0 kg (With gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 180
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 8.3 r/min
Three-Phase 380 VAC / 60 Hz: 10 r/min
Three-Phase 400 VAC / 50 Hz: 8.3 r/min
Three-Phase 400 VAC / 60 Hz: 10 r/min
Three-Phase 415 VAC / 50 Hz: 8.3 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
Three-Phase 380 VAC / 60 Hz: 40 N·m
Three-Phase 400 VAC / 50 Hz: 40 N·m
Three-Phase 400 VAC / 60 Hz: 40 N·m
Three-Phase 415 VAC / 50 Hz: 40 N·m - Permissible Inertia J: 5000×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 8.0 kg (With gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 50
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 30 r/min
Three-Phase 380 VAC / 60 Hz: 36 r/min
Three-Phase 400 VAC / 50 Hz: 30 r/min
Three-Phase 400 VAC / 60 Hz: 36 r/min
Three-Phase 415 VAC / 50 Hz: 30 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
Three-Phase 380 VAC / 60 Hz: 40 N·m
Three-Phase 400 VAC / 50 Hz: 40 N·m
Three-Phase 400 VAC / 60 Hz: 40 N·m
Three-Phase 415 VAC / 50 Hz: 40 N·m - Permissible Inertia J: 5000×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 8.0 kg (With gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 60
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 25 r/min
Three-Phase 380 VAC / 60 Hz: 30 r/min
Three-Phase 400 VAC / 50 Hz: 25 r/min
Three-Phase 400 VAC / 60 Hz: 30 r/min
Three-Phase 415 VAC / 50 Hz: 25 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
Three-Phase 380 VAC / 60 Hz: 40 N·m
Three-Phase 400 VAC / 50 Hz: 40 N·m
Three-Phase 400 VAC / 60 Hz: 40 N·m
Three-Phase 415 VAC / 50 Hz: 40 N·m - Permissible Inertia J: 5000×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 8.0 kg (With gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 75
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 20 r/min
Three-Phase 380 VAC / 60 Hz: 24 r/min
Three-Phase 400 VAC / 50 Hz: 20 r/min
Three-Phase 400 VAC / 60 Hz: 24 r/min
Three-Phase 415 VAC / 50 Hz: 20 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
Three-Phase 380 VAC / 60 Hz: 40 N·m
Three-Phase 400 VAC / 50 Hz: 40 N·m
Three-Phase 400 VAC / 60 Hz: 40 N·m
Three-Phase 415 VAC / 50 Hz: 40 N·m - Permissible Inertia J: 5000×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 8.0 kg (With gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 90
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.54 A
Three-Phase400 VAC / 50 Hz / 0.55 A
Three-Phase400 VAC / 60 Hz / 0.52 A
Three-Phase415 VAC / 50 Hz / 0.54 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m
Three-Phase 380 VAC / 60 Hz: 1.24 N·m
Three-Phase 400 VAC / 50 Hz: 1.47 N·m
Three-Phase 400 VAC / 60 Hz: 1.24 N·m
Three-Phase 415 VAC / 50 Hz: 1.47 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 380 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 400 VAC / 50 Hz: 1.47 N·m / 1300 r/min
Three-Phase 400 VAC / 60 Hz: 1.24 N·m / 1550 r/min
Three-Phase 415 VAC / 50 Hz: 1.47 N·m / 1300 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 17 r/min
Three-Phase 380 VAC / 60 Hz: 20 r/min
Three-Phase 400 VAC / 50 Hz: 17 r/min
Three-Phase 400 VAC / 60 Hz: 20 r/min
Three-Phase 415 VAC / 50 Hz: 17 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 40 N·m
Three-Phase 380 VAC / 60 Hz: 40 N·m
Three-Phase 400 VAC / 50 Hz: 40 N·m
Three-Phase 400 VAC / 60 Hz: 40 N·m
Three-Phase 415 VAC / 50 Hz: 40 N·m - Permissible Inertia J: 5000×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 8.0 kg (With gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
• It cannot be used in combination with inverter. The insulation of the motor winding may deteriorate and be damaged.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 30
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: single-Phase 100 VAC / 50 Hz / 3.1 A
single-Phase 100 VAC / 60 Hz / 3.3 A - Starting Torque (Motor Shaft): single-Phase 100 VAC / 50 Hz: 0.88 N·m
single-Phase 100 VAC / 60 Hz: 0.88 N·m - Rated torque/ Rated Speed (Motor Shaft): single-Phase 100 VAC / 50 Hz: 1.45 N·m / 1250 r/min
single-Phase 100 VAC / 60 Hz: 1.27 N·m / 1500 r/min - The Speed When Installing gearhead: single-Phase 100 VAC / 50 Hz: 50 r/min
single-Phase 100 VAC / 60 Hz: 60 r/min - Permissible Torque of gearhead Output Shaft: single-Phase 100 VAC / 50 Hz: 37.4 N·m
single-Phase 100 VAC / 60 Hz: 32.8 N·m - Permissible Inertia J: 1800×10-4 kg·m2
- capacitor: Product name: CH470CFAUL, Capacity: 47 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 8.0 kg (With gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 12.5
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 1.1 A
Three-Phase 200 VAC / 60 Hz / 1.1 A
Three-Phase 220 VAC / 60 Hz / 0.95 A
Three-Phase 230 VAC / 60 Hz / 0.95 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1.49 N·m
Three-Phase 200 VAC / 60 Hz: 1.25 N·m
Three-Phase 220 VAC / 60 Hz: 1.23 N·m
Three-Phase 230 VAC / 60 Hz: 1.18 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1.49 N·m / 1250 r/min
Three-Phase 200 VAC / 60 Hz: 1.25 N·m / 1500 r/min
Three-Phase 220 VAC / 60 Hz: 1.23 N·m / 1550 r/min
Three-Phase 230 VAC / 60 Hz: 1.18 N·m / 1600 r/min - The Speed When Installing gearhead: Three-Phase 200 VAC / 50 Hz: 120 r/min
Three-Phase 200 VAC / 60 Hz: 144 r/min
Three-Phase 220 VAC / 60 Hz: 144 r/min
Three-Phase 230 VAC / 60 Hz: 144 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 200 VAC / 50 Hz: 13.6 N·m
Three-Phase 200 VAC / 60 Hz: 11.4 N·m
Three-Phase 220 VAC / 60 Hz: 11.2 N·m
Three-Phase 230 VAC / 60 Hz: 10.8 N·m - Permissible Inertia J: 312×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 15
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 1.1 A
Three-Phase 200 VAC / 60 Hz / 1.1 A
Three-Phase 220 VAC / 60 Hz / 0.95 A
Three-Phase 230 VAC / 60 Hz / 0.95 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1.49 N·m
Three-Phase 200 VAC / 60 Hz: 1.25 N·m
Three-Phase 220 VAC / 60 Hz: 1.23 N·m
Three-Phase 230 VAC / 60 Hz: 1.18 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1.49 N·m / 1250 r/min
Three-Phase 200 VAC / 60 Hz: 1.25 N·m / 1500 r/min
Three-Phase 220 VAC / 60 Hz: 1.23 N·m / 1550 r/min
Three-Phase 230 VAC / 60 Hz: 1.18 N·m / 1600 r/min - The Speed When Installing gearhead: Three-Phase 200 VAC / 50 Hz: 100 r/min
Three-Phase 200 VAC / 60 Hz: 120 r/min
Three-Phase 220 VAC / 60 Hz: 120 r/min
Three-Phase 230 VAC / 60 Hz: 120 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 200 VAC / 50 Hz: 16.3 N·m
Three-Phase 200 VAC / 60 Hz: 13.7 N·m
Three-Phase 220 VAC / 60 Hz: 13.5 N·m
Three-Phase 230 VAC / 60 Hz: 12.9 N·m - Permissible Inertia J: 450×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 18
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 1.1 A
Three-Phase 200 VAC / 60 Hz / 1.1 A
Three-Phase 220 VAC / 60 Hz / 0.95 A
Three-Phase 230 VAC / 60 Hz / 0.95 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1.49 N·m
Three-Phase 200 VAC / 60 Hz: 1.25 N·m
Three-Phase 220 VAC / 60 Hz: 1.23 N·m
Three-Phase 230 VAC / 60 Hz: 1.18 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1.49 N·m / 1250 r/min
Three-Phase 200 VAC / 60 Hz: 1.25 N·m / 1500 r/min
Three-Phase 220 VAC / 60 Hz: 1.23 N·m / 1550 r/min
Three-Phase 230 VAC / 60 Hz: 1.18 N·m / 1600 r/min - The Speed When Installing gearhead: Three-Phase 200 VAC / 50 Hz: 83 r/min
Three-Phase 200 VAC / 60 Hz: 100 r/min
Three-Phase 220 VAC / 60 Hz: 100 r/min
Three-Phase 230 VAC / 60 Hz: 100 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 200 VAC / 50 Hz: 19.6 N·m
Three-Phase 200 VAC / 60 Hz: 16.4 N·m
Three-Phase 220 VAC / 60 Hz: 16.2 N·m
Three-Phase 230 VAC / 60 Hz: 15.5 N·m - Permissible Inertia J: 648×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 25
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 1.1 A
Three-Phase 200 VAC / 60 Hz / 1.1 A
Three-Phase 220 VAC / 60 Hz / 0.95 A
Three-Phase 230 VAC / 60 Hz / 0.95 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1.49 N·m
Three-Phase 200 VAC / 60 Hz: 1.25 N·m
Three-Phase 220 VAC / 60 Hz: 1.23 N·m
Three-Phase 230 VAC / 60 Hz: 1.18 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1.49 N·m / 1250 r/min
Three-Phase 200 VAC / 60 Hz: 1.25 N·m / 1500 r/min
Three-Phase 220 VAC / 60 Hz: 1.23 N·m / 1550 r/min
Three-Phase 230 VAC / 60 Hz: 1.18 N·m / 1600 r/min - The Speed When Installing gearhead: Three-Phase 200 VAC / 50 Hz: 60 r/min
Three-Phase 200 VAC / 60 Hz: 72 r/min
Three-Phase 220 VAC / 60 Hz: 72 r/min
Three-Phase 230 VAC / 60 Hz: 72 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 200 VAC / 50 Hz: 27.2 N·m
Three-Phase 200 VAC / 60 Hz: 22.8 N·m
Three-Phase 220 VAC / 60 Hz: 22.4 N·m
Three-Phase 230 VAC / 60 Hz: 21.5 N·m - Permissible Inertia J: 1250×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 30
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 1.1 A
Three-Phase 200 VAC / 60 Hz / 1.1 A
Three-Phase 220 VAC / 60 Hz / 0.95 A
Three-Phase 230 VAC / 60 Hz / 0.95 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1.49 N·m
Three-Phase 200 VAC / 60 Hz: 1.25 N·m
Three-Phase 220 VAC / 60 Hz: 1.23 N·m
Three-Phase 230 VAC / 60 Hz: 1.18 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1.49 N·m / 1250 r/min
Three-Phase 200 VAC / 60 Hz: 1.25 N·m / 1500 r/min
Three-Phase 220 VAC / 60 Hz: 1.23 N·m / 1550 r/min
Three-Phase 230 VAC / 60 Hz: 1.18 N·m / 1600 r/min - The Speed When Installing gearhead: Three-Phase 200 VAC / 50 Hz: 50 r/min
Three-Phase 200 VAC / 60 Hz: 60 r/min
Three-Phase 220 VAC / 60 Hz: 60 r/min
Three-Phase 230 VAC / 60 Hz: 60 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 200 VAC / 50 Hz: 32.6 N·m
Three-Phase 200 VAC / 60 Hz: 27.4 N·m
Three-Phase 220 VAC / 60 Hz: 26.9 N·m
Three-Phase 230 VAC / 60 Hz: 25.8 N·m - Permissible Inertia J: 1800×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 36
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 1.1 A
Three-Phase 200 VAC / 60 Hz / 1.1 A
Three-Phase 220 VAC / 60 Hz / 0.95 A
Three-Phase 230 VAC / 60 Hz / 0.95 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1.49 N·m
Three-Phase 200 VAC / 60 Hz: 1.25 N·m
Three-Phase 220 VAC / 60 Hz: 1.23 N·m
Three-Phase 230 VAC / 60 Hz: 1.18 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1.49 N·m / 1250 r/min
Three-Phase 200 VAC / 60 Hz: 1.25 N·m / 1500 r/min
Three-Phase 220 VAC / 60 Hz: 1.23 N·m / 1550 r/min
Three-Phase 230 VAC / 60 Hz: 1.18 N·m / 1600 r/min - The Speed When Installing gearhead: Three-Phase 200 VAC / 50 Hz: 42 r/min
Three-Phase 200 VAC / 60 Hz: 50 r/min
Three-Phase 220 VAC / 60 Hz: 50 r/min
Three-Phase 230 VAC / 60 Hz: 50 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 200 VAC / 50 Hz: 36 N·m
Three-Phase 200 VAC / 60 Hz: 32.9 N·m
Three-Phase 220 VAC / 60 Hz: 32.3 N·m
Three-Phase 230 VAC / 60 Hz: 31 N·m - Permissible Inertia J: 2592×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 5
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 1.1 A
Three-Phase 200 VAC / 60 Hz / 1.1 A
Three-Phase 220 VAC / 60 Hz / 0.95 A
Three-Phase 230 VAC / 60 Hz / 0.95 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1.49 N·m
Three-Phase 200 VAC / 60 Hz: 1.25 N·m
Three-Phase 220 VAC / 60 Hz: 1.23 N·m
Three-Phase 230 VAC / 60 Hz: 1.18 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1.49 N·m / 1250 r/min
Three-Phase 200 VAC / 60 Hz: 1.25 N·m / 1500 r/min
Three-Phase 220 VAC / 60 Hz: 1.23 N·m / 1550 r/min
Three-Phase 230 VAC / 60 Hz: 1.18 N·m / 1600 r/min - The Speed When Installing gearhead: Three-Phase 200 VAC / 50 Hz: 300 r/min
Three-Phase 200 VAC / 60 Hz: 360 r/min
Three-Phase 220 VAC / 60 Hz: 360 r/min
Three-Phase 230 VAC / 60 Hz: 360 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 200 VAC / 50 Hz: 5.4 N·m
Three-Phase 200 VAC / 60 Hz: 4.6 N·m
Three-Phase 220 VAC / 60 Hz: 4.5 N·m
Three-Phase 230 VAC / 60 Hz: 4.3 N·m - Permissible Inertia J: 50×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 10.0 kg (With gearhead)
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.
[Note]
• If a motor overheats for any reason, the thermal protector is activated and the motor is stopped. When the motor temperature drops, the thermal protector closes and the motor restarts automatically. Be sure to turn the power supply off before inspecting.