Torque Motor K Series
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 120
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC1.9 VAC※: Continuous
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.5 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz / 1.18 A / 117 W
single-Phase 100 VAC / 60 Hz / 1.34 A / 134 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 100 VAC / 50 Hz / 0.72 A / 45 W
single-Phase 100 VAC / 60 Hz / 0.91 A / 55 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 300 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 80 mN·m (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60 Hz: 85 mN·m (Torque Setting VoltageDC1.5 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 10 N·m
60 Hz: 10 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 6.3 N·m
60 Hz: 6.7 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 100 VAC / 50Hz: 4 W (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60Hz: 4 W (Torque Setting VoltageDC1.5 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 260 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 220 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 50 mN·m (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 45 mN·m (Torque Setting VoltageDC1.5 VAC※) - Permissible Inertia J: 1875×10-4 kg·m2
- capacitor: Product name: CH180CFAUL2, Capacity: 18 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 120
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.4 VAC※: Continuous
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.4 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz / 1.22 A / 134 W
single-Phase 115 VAC / 60 Hz / 1.29 A / 147 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 110 VAC / 60 Hz / 0.76 A / 51 W
single-Phase 115 VAC / 60 Hz / 0.79 A / 55 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.4 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 10 N·m
- gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 7.9 N·m
- Maximum Output Power (5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 23 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 23 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 110 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.4 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 250 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 250 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.4 VAC※) - Permissible Inertia J: 1875×10-4 kg·m2
- capacitor: Product name: CH140CFAUL2, Capacity: 14 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 150
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC1.9 VAC※: Continuous
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.5 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz / 1.18 A / 117 W
single-Phase 100 VAC / 60 Hz / 1.34 A / 134 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 100 VAC / 50 Hz / 0.72 A / 45 W
single-Phase 100 VAC / 60 Hz / 0.91 A / 55 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 300 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 80 mN·m (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60 Hz: 85 mN·m (Torque Setting VoltageDC1.5 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 10 N·m
60 Hz: 10 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 7.9 N·m
60 Hz: 8.4 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 100 VAC / 50Hz: 4 W (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60Hz: 4 W (Torque Setting VoltageDC1.5 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 260 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 220 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 50 mN·m (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 45 mN·m (Torque Setting VoltageDC1.5 VAC※) - Permissible Inertia J: 1875×10-4 kg·m2
- capacitor: Product name: CH180CFAUL2, Capacity: 18 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 15
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC1.9 VAC※: Continuous
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.5 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz / 1.18 A / 117 W
single-Phase 100 VAC / 60 Hz / 1.34 A / 134 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 100 VAC / 50 Hz / 0.72 A / 45 W
single-Phase 100 VAC / 60 Hz / 0.91 A / 55 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 300 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 80 mN·m (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60 Hz: 85 mN·m (Torque Setting VoltageDC1.5 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 4.3 N·m
60 Hz: 3.6 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.97 N·m
60 Hz: 1 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 100 VAC / 50Hz: 4 W (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60Hz: 4 W (Torque Setting VoltageDC1.5 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 260 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 220 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 50 mN·m (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 45 mN·m (Torque Setting VoltageDC1.5 VAC※) - Permissible Inertia J: 168×10-4 kg·m2
- capacitor: Product name: CH180CFAUL2, Capacity: 18 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 180
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC1.9 VAC※: Continuous
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.5 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz / 1.18 A / 117 W
single-Phase 100 VAC / 60 Hz / 1.34 A / 134 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 100 VAC / 50 Hz / 0.72 A / 45 W
single-Phase 100 VAC / 60 Hz / 0.91 A / 55 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 300 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 80 mN·m (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60 Hz: 85 mN·m (Torque Setting VoltageDC1.5 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 10 N·m
60 Hz: 10 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 9.5 N·m
60 Hz: 10 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 100 VAC / 50Hz: 4 W (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60Hz: 4 W (Torque Setting VoltageDC1.5 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 260 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 220 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 50 mN·m (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 45 mN·m (Torque Setting VoltageDC1.5 VAC※) - Permissible Inertia J: 1875×10-4 kg·m2
- capacitor: Product name: CH180CFAUL2, Capacity: 18 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 180
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.4 VAC※: Continuous
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.4 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz / 1.22 A / 134 W
single-Phase 115 VAC / 60 Hz / 1.29 A / 147 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 110 VAC / 60 Hz / 0.76 A / 51 W
single-Phase 115 VAC / 60 Hz / 0.79 A / 55 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.4 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 10 N·m
- gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 10 N·m
- Maximum Output Power (5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 23 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 23 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 110 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.4 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 250 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 250 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.4 VAC※) - Permissible Inertia J: 1875×10-4 kg·m2
- capacitor: Product name: CH140CFAUL2, Capacity: 14 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 18
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC1.9 VAC※: Continuous
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.5 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz / 1.18 A / 117 W
single-Phase 100 VAC / 60 Hz / 1.34 A / 134 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 100 VAC / 50 Hz / 0.72 A / 45 W
single-Phase 100 VAC / 60 Hz / 0.91 A / 55 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 300 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 80 mN·m (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60 Hz: 85 mN·m (Torque Setting VoltageDC1.5 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 5.1 N·m
60 Hz: 4.4 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 1.2 N·m
60 Hz: 1.2 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 100 VAC / 50Hz: 4 W (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60Hz: 4 W (Torque Setting VoltageDC1.5 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 260 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 220 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 50 mN·m (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 45 mN·m (Torque Setting VoltageDC1.5 VAC※) - Permissible Inertia J: 243×10-4 kg·m2
- capacitor: Product name: CH180CFAUL2, Capacity: 18 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 30
- Rotation Direction: opposite direction as the motor shaft
- Service Rating (When Locked): single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.4 VAC※: Continuous
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.4 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz / 1.22 A / 134 W
single-Phase 115 VAC / 60 Hz / 1.29 A / 147 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 110 VAC / 60 Hz / 0.76 A / 51 W
single-Phase 115 VAC / 60 Hz / 0.79 A / 55 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.4 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 7.7 N·m
- gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 2.2 N·m
- Maximum Output Power (5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 23 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 23 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 110 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.4 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 250 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 250 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.4 VAC※) - Permissible Inertia J: 675×10-4 kg·m2
- capacitor: Product name: CH140CFAUL2, Capacity: 14 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 36
- Rotation Direction: opposite direction as the motor shaft
- Service Rating (When Locked): single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.4 VAC※: Continuous
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.4 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz / 1.22 A / 134 W
single-Phase 115 VAC / 60 Hz / 1.29 A / 147 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 110 VAC / 60 Hz / 0.76 A / 51 W
single-Phase 115 VAC / 60 Hz / 0.79 A / 55 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.4 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 9.2 N·m
- gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 2.6 N·m
- Maximum Output Power (5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 23 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 23 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 110 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.4 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 250 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 250 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.4 VAC※) - Permissible Inertia J: 972×10-4 kg·m2
- capacitor: Product name: CH140CFAUL2, Capacity: 14 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 3
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.4 VAC※: Continuous
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.4 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz / 1.22 A / 134 W
single-Phase 115 VAC / 60 Hz / 1.29 A / 147 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 110 VAC / 60 Hz / 0.76 A / 51 W
single-Phase 115 VAC / 60 Hz / 0.79 A / 55 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.4 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 0.85 N·m
- gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 0.24 N·m
- Maximum Output Power (5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 23 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 23 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 110 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.4 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 250 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 250 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.4 VAC※) - Permissible Inertia J: 6.7×10-4 kg·m2
- capacitor: Product name: CH140CFAUL2, Capacity: 14 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 50
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC1.9 VAC※: Continuous
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.5 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz / 1.18 A / 117 W
single-Phase 100 VAC / 60 Hz / 1.34 A / 134 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 100 VAC / 50 Hz / 0.72 A / 45 W
single-Phase 100 VAC / 60 Hz / 0.91 A / 55 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 300 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 80 mN·m (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60 Hz: 85 mN·m (Torque Setting VoltageDC1.5 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 10 N·m
60 Hz: 9.9 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 2.6 N·m
60 Hz: 2.8 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 100 VAC / 50Hz: 4 W (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60Hz: 4 W (Torque Setting VoltageDC1.5 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 260 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 220 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 50 mN·m (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 45 mN·m (Torque Setting VoltageDC1.5 VAC※) - Permissible Inertia J: 1875×10-4 kg·m2
- capacitor: Product name: CH180CFAUL2, Capacity: 18 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 50
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.4 VAC※: Continuous
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.4 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz / 1.22 A / 134 W
single-Phase 115 VAC / 60 Hz / 1.29 A / 147 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 110 VAC / 60 Hz / 0.76 A / 51 W
single-Phase 115 VAC / 60 Hz / 0.79 A / 55 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.4 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 10 N·m
- gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 3.3 N·m
- Maximum Output Power (5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 23 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 23 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 110 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.4 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 250 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 250 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.4 VAC※) - Permissible Inertia J: 1875×10-4 kg·m2
- capacitor: Product name: CH140CFAUL2, Capacity: 14 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 5
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC1.9 VAC※: Continuous
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.5 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz / 1.18 A / 117 W
single-Phase 100 VAC / 60 Hz / 1.34 A / 134 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 100 VAC / 50 Hz / 0.72 A / 45 W
single-Phase 100 VAC / 60 Hz / 0.91 A / 55 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 300 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 80 mN·m (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60 Hz: 85 mN·m (Torque Setting VoltageDC1.5 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 1.4 N·m
60 Hz: 1.2 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.32 N·m
60 Hz: 0.34 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 100 VAC / 50Hz: 4 W (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60Hz: 4 W (Torque Setting VoltageDC1.5 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 260 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 220 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 50 mN·m (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 45 mN·m (Torque Setting VoltageDC1.5 VAC※) - Permissible Inertia J: 18.7×10-4 kg·m2
- capacitor: Product name: CH180CFAUL2, Capacity: 18 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 5
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.4 VAC※: Continuous
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.4 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz / 1.22 A / 134 W
single-Phase 115 VAC / 60 Hz / 1.29 A / 147 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 110 VAC / 60 Hz / 0.76 A / 51 W
single-Phase 115 VAC / 60 Hz / 0.79 A / 55 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.4 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 1.4 N·m
- gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 0.41 N·m
- Maximum Output Power (5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 23 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 23 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 110 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.4 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 250 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 250 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.4 VAC※) - Permissible Inertia J: 18.7×10-4 kg·m2
- capacitor: Product name: CH140CFAUL2, Capacity: 14 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 60
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.4 VAC※: Continuous
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.4 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz / 1.22 A / 134 W
single-Phase 115 VAC / 60 Hz / 1.29 A / 147 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 110 VAC / 60 Hz / 0.76 A / 51 W
single-Phase 115 VAC / 60 Hz / 0.79 A / 55 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.4 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 10 N·m
- gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 4 N·m
- Maximum Output Power (5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 23 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 23 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 110 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.4 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 250 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 250 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.4 VAC※) - Permissible Inertia J: 1875×10-4 kg·m2
- capacitor: Product name: CH140CFAUL2, Capacity: 14 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 6
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.4 VAC※: Continuous
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.4 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz / 1.22 A / 134 W
single-Phase 115 VAC / 60 Hz / 1.29 A / 147 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 110 VAC / 60 Hz / 0.76 A / 51 W
single-Phase 115 VAC / 60 Hz / 0.79 A / 55 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.4 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 1.7 N·m
- gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 0.49 N·m
- Maximum Output Power (5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 23 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 23 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 110 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.4 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 250 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 250 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.4 VAC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.4 VAC※) - Permissible Inertia J: 27×10-4 kg·m2
- capacitor: Product name: CH140CFAUL2, Capacity: 14 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 7.5
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC1.9 VAC※: Continuous
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.5 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz / 1.18 A / 117 W
single-Phase 100 VAC / 60 Hz / 1.34 A / 134 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 100 VAC / 50 Hz / 0.72 A / 45 W
single-Phase 100 VAC / 60 Hz / 0.91 A / 55 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 300 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 80 mN·m (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60 Hz: 85 mN·m (Torque Setting VoltageDC1.5 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 2.1 N·m
60 Hz: 1.8 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.49 N·m
60 Hz: 0.52 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 100 VAC / 50Hz: 4 W (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60Hz: 4 W (Torque Setting VoltageDC1.5 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 260 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 220 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 50 mN·m (Torque Setting VoltageDC1.9 VAC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 45 mN·m (Torque Setting VoltageDC1.5 VAC※) - Permissible Inertia J: 42×10-4 kg·m2
- capacitor: Product name: CH180CFAUL2, Capacity: 18 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).