Torque Motor K Series
K-series torque motor – variants (power, shaft type, voltage)
The K-series torque motors are suitable for applications with constant traction and simple speed control via the supply voltage.
Please select the service first; then the wave type and voltage are automatically limited to the available combinations.
Characteristics
- High start-up torque, falling torque-speed characteristic (torque ~ U2).
- Operation as a brake possible (direct current for constant tractive force).
- Integrated thermal protection (automatically resetting).
- Degree of protection IP20.
- contain capacitor (J/U/E depending on voltage); Not specified on the nameplate.
- Accessories such as capstan included; Gearbox available separately (can only be combined with pinion shaft); not included in this variant article.
Varianten & Hinweise
- Performance: 3 W, 6 W, 10 W, 20 W.
- Wellenart: Pinion shaft "GN" or round shaft "A" (round shaft can be combined without transmission).
Voltage: 100 V / 110-115 V / 200 V / 220-230 V.
- (Angular gears cannot be combined.)
(capacitor type J/U/E depending on the voltage variant); Not separately selectable.
Scope of delivery
- Motor including suitable operating capacitor and capacitor cap.
- Frame Size: 80 mm
- Shaft/Gear Type: Pinion Shaft Type
- Gear Ratio: -
- Rotation Direction: Depends on the combination gear head.
- Voltage/ Frequency/ Maximum Output Current/ Input at Maximum Output Power (5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz / 0.41 A / 80 W
single-Phase 230 VAC / 50 Hz / 0.45 A / 90 W
single-Phase 220 VAC / 60 Hz / 0.39 A / 80 W
single-Phase 230 VAC / 60 Hz / 0.4 A / 80 W - Voltage/ Frequency/ Maximum Output Current/ Input at Maximum Output Power (Continuous Service Rating): single-Phase 115 VAC / 50 Hz / 0.18 A / 20 W
single-Phase 115 VAC / 60 Hz / 0.24 A / 25 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 220 mN·m
single-Phase 230 VAC / 50 Hz: 220 mN·m
single-Phase 220 VAC / 60 Hz: 210 mN·m
single-Phase 230 VAC / 60 Hz: 210 mN·m - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 115 VAC / 50 Hz: 65 mN·m
single-Phase 115 VAC / 60 Hz: 70 mN·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 10 W
single-Phase 230 VAC / 50 Hz: 10 W
single-Phase 220 VAC / 60 Hz: 12 W
single-Phase 230 VAC / 60 Hz: 12 W - Maximum Output Power (Continuous Service Rating): single-Phase 115 VAC / 50Hz: 2.8 W
single-Phase 115 VAC / 60Hz: 3.3 W - Speed at Maximum Output Power/ Torque at Maximum Output Power (Motor Shaft, 5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 750 r/min / 130 mN·m
single-Phase 230 V / 50 Hz: 750 r/min / 130 mN·m
single-Phase 220 VAC / 60 Hz: 900 r/min / 130 mN·m
single-Phase 230 V / 60 Hz: 900 r/min / 130 mN·m - Speed at Maximum Output Power/ Torque at Maximum Output Power (Motor Shaft, Continuous Service Rating): single-Phase 115 VAC / 50 Hz: 750 r/min / 35 mN·m
single-Phase 115 VAC / 60 Hz: 900 r/min / 35 mN·m - Permissible Inertia J: Depends on the combination gear head.
- capacitor: Product name: CH30BFAUL, Capacity: 3 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
K-series Torque motor – variants (power, wave type, voltage)
The K-series Torque motors are suitable for applications with constant traction and simple speed control via the supply voltage.
Please select the performance first; After that, the wave type and voltage are automatically restricted to available combinations.
features
• High start-up torque, falling torque-speed characteristic (torque ~ U2).
• Operation as a brake possible (DC voltage for constant tractive force).
• Thermal protection integrated (automatically resetting).
• Protection rating IP20.
• capacitor supplied (J/U/E depending on voltage); Not on the nameplate.
• Accessories such as capacitor cap included; Gearboxes available separately (combinable only with Pinion Shaft); Not included in this variant article.
Varianten & Hinweise
• Performance: 3 W, 6 W, 10 W, 20 W.
• Wellentyp: Pinion shaft "GN" or round shaft "A" (round shaft without transmission can be combined).
• Voltage: 100 V / 110–115 V / 200 V / 220–230 V.
• (Angular gearbox cannot be combined.)
(capacitor type J/U/E depending on the voltage variant); Not separately selectable.
Scope of delivery
• Motor including suitable operating capacitor and capacitor cap.
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 100
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC2.5 VAC※: Continuous
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.8 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz / 0.43 A / 43 W
single-Phase 100 VAC / 60 Hz / 0.53 A / 53 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 100 VAC / 50 Hz / 0.3 A / 21 W
single-Phase 100 VAC / 60 Hz / 0.35 A / 22 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60 Hz: 20 mN·m (Torque Setting VoltageDC1.8 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 3 N·m
60 Hz: 3 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 1.2 N·m
60 Hz: 1.3 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 2.8 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 100 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60Hz: 1 W (Torque Setting VoltageDC1.8 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 36 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 11 mN·m (Torque Setting VoltageDC1.8 VAC※) - Permissible Inertia J: 155×10-4 kg·m2
- capacitor: Product name: CH70CFAUL2, Capacity: 7 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 100
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz / 0.49 A / 53 W
single-Phase 115 VAC / 60 Hz / 0.51 A / 58 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 110 VAC / 60 Hz / 0.31 A / 22 W
single-Phase 115 VAC / 60 Hz / 0.33 A / 24 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※)
single-Phase 115 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 3 N·m
- gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 1.7 N·m
- Maximum Output Power (5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 110 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※)
single-Phase 115 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※) - Permissible Inertia J: 155×10-4 kg·m2
- capacitor: Product name: CH60CFAUL2, Capacity: 6 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 12.5
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC2.5 VAC※: Continuous
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.8 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz / 0.43 A / 43 W
single-Phase 100 VAC / 60 Hz / 0.53 A / 53 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 100 VAC / 50 Hz / 0.3 A / 21 W
single-Phase 100 VAC / 60 Hz / 0.35 A / 22 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60 Hz: 20 mN·m (Torque Setting VoltageDC1.8 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 0.71 N·m
60 Hz: 0.71 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.18 N·m
60 Hz: 0.2 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 2.8 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 100 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60Hz: 1 W (Torque Setting VoltageDC1.8 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 36 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 11 mN·m (Torque Setting VoltageDC1.8 VAC※) - Permissible Inertia J: 9.6×10-4 kg·m2
- capacitor: Product name: CH70CFAUL2, Capacity: 7 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 12.5
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz / 0.49 A / 53 W
single-Phase 115 VAC / 60 Hz / 0.51 A / 58 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 110 VAC / 60 Hz / 0.31 A / 22 W
single-Phase 115 VAC / 60 Hz / 0.33 A / 24 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※)
single-Phase 115 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 0.71 N·m
- gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 0.25 N·m
- Maximum Output Power (5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 110 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※)
single-Phase 115 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※) - Permissible Inertia J: 9.6×10-4 kg·m2
- capacitor: Product name: CH60CFAUL2, Capacity: 6 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 120
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC2.5 VAC※: Continuous
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.8 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz / 0.43 A / 43 W
single-Phase 100 VAC / 60 Hz / 0.53 A / 53 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 100 VAC / 50 Hz / 0.3 A / 21 W
single-Phase 100 VAC / 60 Hz / 0.35 A / 22 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60 Hz: 20 mN·m (Torque Setting VoltageDC1.8 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 3 N·m
60 Hz: 3 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 1.4 N·m
60 Hz: 1.6 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 2.8 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 100 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60Hz: 1 W (Torque Setting VoltageDC1.8 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 36 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 11 mN·m (Torque Setting VoltageDC1.8 VAC※) - Permissible Inertia J: 155×10-4 kg·m2
- capacitor: Product name: CH70CFAUL2, Capacity: 7 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 150
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC2.5 VAC※: Continuous
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.8 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz / 0.43 A / 43 W
single-Phase 100 VAC / 60 Hz / 0.53 A / 53 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 100 VAC / 50 Hz / 0.3 A / 21 W
single-Phase 100 VAC / 60 Hz / 0.35 A / 22 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60 Hz: 20 mN·m (Torque Setting VoltageDC1.8 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 3 N·m
60 Hz: 3 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 1.8 N·m
60 Hz: 2 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 2.8 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 100 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60Hz: 1 W (Torque Setting VoltageDC1.8 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 36 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 11 mN·m (Torque Setting VoltageDC1.8 VAC※) - Permissible Inertia J: 155×10-4 kg·m2
- capacitor: Product name: CH70CFAUL2, Capacity: 7 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 180
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz / 0.49 A / 53 W
single-Phase 115 VAC / 60 Hz / 0.51 A / 58 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 110 VAC / 60 Hz / 0.31 A / 22 W
single-Phase 115 VAC / 60 Hz / 0.33 A / 24 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※)
single-Phase 115 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 3 N·m
- gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 3 N·m
- Maximum Output Power (5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 110 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※)
single-Phase 115 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※) - Permissible Inertia J: 155×10-4 kg·m2
- capacitor: Product name: CH60CFAUL2, Capacity: 6 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 18
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC2.5 VAC※: Continuous
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.8 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz / 0.43 A / 43 W
single-Phase 100 VAC / 60 Hz / 0.53 A / 53 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 100 VAC / 50 Hz / 0.3 A / 21 W
single-Phase 100 VAC / 60 Hz / 0.35 A / 22 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60 Hz: 20 mN·m (Torque Setting VoltageDC1.8 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 1 N·m
60 Hz: 1 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.26 N·m
60 Hz: 0.29 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 2.8 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 100 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60Hz: 1 W (Torque Setting VoltageDC1.8 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 36 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 11 mN·m (Torque Setting VoltageDC1.8 VAC※) - Permissible Inertia J: 20×10-4 kg·m2
- capacitor: Product name: CH70CFAUL2, Capacity: 7 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 25
- Rotation Direction: opposite direction as the motor shaft
- Service Rating (When Locked): single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz / 0.49 A / 53 W
single-Phase 115 VAC / 60 Hz / 0.51 A / 58 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 110 VAC / 60 Hz / 0.31 A / 22 W
single-Phase 115 VAC / 60 Hz / 0.33 A / 24 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※)
single-Phase 115 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 1.3 N·m
- gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 0.46 N·m
- Maximum Output Power (5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 110 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※)
single-Phase 115 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※) - Permissible Inertia J: 38×10-4 kg·m2
- capacitor: Product name: CH60CFAUL2, Capacity: 6 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 3.6
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC2.5 VAC※: Continuous
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.8 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz / 0.43 A / 43 W
single-Phase 100 VAC / 60 Hz / 0.53 A / 53 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 100 VAC / 50 Hz / 0.3 A / 21 W
single-Phase 100 VAC / 60 Hz / 0.35 A / 22 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60 Hz: 20 mN·m (Torque Setting VoltageDC1.8 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 0.2 N·m
60 Hz: 0.2 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.052 N·m
60 Hz: 0.058 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 2.8 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 100 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60Hz: 1 W (Torque Setting VoltageDC1.8 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 36 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 11 mN·m (Torque Setting VoltageDC1.8 VAC※) - Permissible Inertia J: 0.8×10-4 kg·m2
- capacitor: Product name: CH70CFAUL2, Capacity: 7 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 3.6
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz / 0.49 A / 53 W
single-Phase 115 VAC / 60 Hz / 0.51 A / 58 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 110 VAC / 60 Hz / 0.31 A / 22 W
single-Phase 115 VAC / 60 Hz / 0.33 A / 24 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※)
single-Phase 115 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 0.2 N·m
- gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 0.073 N·m
- Maximum Output Power (5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 110 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※)
single-Phase 115 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※) - Permissible Inertia J: 0.8×10-4 kg·m2
- capacitor: Product name: CH60CFAUL2, Capacity: 6 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).