Torque Motor K Series
- Power Supply Input Voltage: single-Phase 100/110/115 VAC±10%
Single-Phase200/220/230 VAC±10% - Power Supply Input Frequency: 50/60 Hz
- Control Power Supply: 24 VDC±10%, 100 mA or more.
- Input Signal: Photocoupler input method input resistance 4.7 kΩ
CWinput, CCWinput, INT/EXT switchinginput, alarm reset input - Output Signal: Open collector output 4.5–26.4 VDC or less 40 mA or less
Alarm output - Torque Setting Method: • Setting by internal torque setting device (TORQUE)
• Setting by external setting device: Optional (sold separately) PAVR-20KZ (20 kΩ, 1/4 W)
• Setting by external Voltage: 0–5 VDC or 0–10 VDC switching, 1 mA or more. Fine adjustment can be made using the torque fine adjustment setting device (ADJUST). - Maximum Extension Distance: Between motor and circuit
- Protective Function: The motor will stop, the alarm LED will flash, and an alarm signal will be output under the following conditions.
• When the motor's built-in thermal protector operates (OPEN)
• Motor cable disconnection • Poor connection
- Frame Size: 90 mm
- Shaft/Gear Type: Round Shaft Type
- Gear Ratio: -
- Service Rating (When Locked): single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous
single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC1.2 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz / 0.67 A / 128 W
single-Phase 200 VAC / 60 Hz / 0.69 A / 138 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 200 VAC / 50 Hz / 0.38 A / 47 W
single-Phase 200 VAC / 60 Hz / 0.42 A / 50 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 200 VAC / 60 Hz: 300 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 200 VAC / 50 Hz: 80 mN·m (Torque Setting VoltageDC1.6 VAC※)
single-Phase 200 VAC / 60 Hz: 85 mN·m (Torque Setting VoltageDC1.2 VAC※) - Maximum Output Power (5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 18 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 200 VAC / 60 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 200 VAC / 50Hz: 4 W (Torque Setting VoltageDC1.6 VAC※)
single-Phase 200 VAC / 60Hz: 4 W (Torque Setting VoltageDC1.2 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 750 r/min / 240 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 200 VAC / 60 Hz: 900 r/min / 220 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 200 VAC / 50 Hz: 750 r/min / 50 mN·m (Torque Setting VoltageDC1.6 VAC※)
single-Phase 200 VAC / 60 Hz: 900 r/min / 45 mN·m (Torque Setting VoltageDC1.2 VAC※) - capacitor: Product name: CH45BFAUL, Capacity: 4.5 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 2.5 kg
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
- Frame Size: 90 mm
- Shaft/Gear Type: Round Shaft Type
- Gear Ratio: -
- Service Rating (When Locked): single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC1.5 VAC※: Continuous
single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC1.1 VAC※: Continuous
single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC1.5 VAC※: Continuous
single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC1.1 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz / 0.74 A / 151 W
single-Phase 220 VAC / 60 Hz / 0.72 A / 157 W
single-Phase 230 VAC / 50 Hz / 0.8 A / 169 W
single-Phase 230 VAC / 60 Hz / 0.76 A / 173 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 220 VAC / 50 Hz / 0.4 A / 54 W
single-Phase 220 VAC / 60 Hz / 0.39 A / 49 W
single-Phase 230 VAC / 50 Hz / 0.43 A / 60 W
single-Phase 230 VAC / 60 Hz / 0.41 A / 54 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 220 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 50 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 220 VAC / 50 Hz: 85 mN·m (Torque Setting VoltageDC1.5 VAC※)
single-Phase 220 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.1 VAC※)
single-Phase 230 VAC / 50 Hz: 85 mN·m (Torque Setting VoltageDC1.5 VAC※)
single-Phase 230 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.1 VAC※) - Maximum Output Power (5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 220 VAC / 60 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 50 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 60 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 220 VAC / 50Hz: 4.5 W (Torque Setting VoltageDC1.5 VAC※)
single-Phase 220 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.1 VAC※)
single-Phase 230 VAC / 50Hz: 4.5 W (Torque Setting VoltageDC1.5 VAC※)
single-Phase 230 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.1 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 750 r/min / 260 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 220 VAC / 60 Hz: 900 r/min / 220 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 230 VAC / 50 Hz: 750 r/min / 260 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 230 VAC / 60 Hz: 900 r/min / 220 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 220 VAC / 50 Hz: 750 r/min / 60 mN·m (Torque Setting VoltageDC1.5 VAC※)
single-Phase 220 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.1 VAC※)
single-Phase 230 VAC / 50 Hz: 750 r/min / 60 mN·m (Torque Setting VoltageDC1.5 VAC※)
single-Phase 230 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.1 VAC※) - capacitor: Product name: CH40BFAUL, Capacity: 4 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 2.5 kg
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 9
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous
single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC1.2 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz / 0.67 A / 128 W
single-Phase 200 VAC / 60 Hz / 0.69 A / 138 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 200 VAC / 50 Hz / 0.38 A / 47 W
single-Phase 200 VAC / 60 Hz / 0.42 A / 50 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 200 VAC / 60 Hz: 300 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 200 VAC / 50 Hz: 80 mN·m (Torque Setting VoltageDC1.6 VAC※)
single-Phase 200 VAC / 60 Hz: 85 mN·m (Torque Setting VoltageDC1.2 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 2.6 N·m
60 Hz: 2.2 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.58 N·m
60 Hz: 0.62 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 18 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 200 VAC / 60 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 200 VAC / 50Hz: 4 W (Torque Setting VoltageDC1.6 VAC※)
single-Phase 200 VAC / 60Hz: 4 W (Torque Setting VoltageDC1.2 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 750 r/min / 240 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 200 VAC / 60 Hz: 900 r/min / 220 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 200 VAC / 50 Hz: 750 r/min / 50 mN·m (Torque Setting VoltageDC1.6 VAC※)
single-Phase 200 VAC / 60 Hz: 900 r/min / 45 mN·m (Torque Setting VoltageDC1.2 VAC※) - Permissible Inertia J: 60×10-4 kg·m2
- capacitor: Product name: CH45BFAUL, Capacity: 4.5 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 9
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC1.5 VAC※: Continuous
single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC1.1 VAC※: Continuous
single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC1.5 VAC※: Continuous
single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC1.1 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz / 0.74 A / 151 W
single-Phase 220 VAC / 60 Hz / 0.72 A / 157 W
single-Phase 230 VAC / 50 Hz / 0.8 A / 169 W
single-Phase 230 VAC / 60 Hz / 0.76 A / 173 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 220 VAC / 50 Hz / 0.4 A / 54 W
single-Phase 220 VAC / 60 Hz / 0.39 A / 49 W
single-Phase 230 VAC / 50 Hz / 0.43 A / 60 W
single-Phase 230 VAC / 60 Hz / 0.41 A / 54 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 220 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 50 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 220 VAC / 50 Hz: 85 mN·m (Torque Setting VoltageDC1.5 VAC※)
single-Phase 220 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.1 VAC※)
single-Phase 230 VAC / 50 Hz: 85 mN·m (Torque Setting VoltageDC1.5 VAC※)
single-Phase 230 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.1 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 2.6 N·m
60 Hz: 2.6 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.62 N·m
60 Hz: 0.73 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 220 VAC / 60 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 50 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 60 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 220 VAC / 50Hz: 4.5 W (Torque Setting VoltageDC1.5 VAC※)
single-Phase 220 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.1 VAC※)
single-Phase 230 VAC / 50Hz: 4.5 W (Torque Setting VoltageDC1.5 VAC※)
single-Phase 230 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.1 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 750 r/min / 260 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 220 VAC / 60 Hz: 900 r/min / 220 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 230 VAC / 50 Hz: 750 r/min / 260 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 230 VAC / 60 Hz: 900 r/min / 220 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 220 VAC / 50 Hz: 750 r/min / 60 mN·m (Torque Setting VoltageDC1.5 VAC※)
single-Phase 220 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.1 VAC※)
single-Phase 230 VAC / 50 Hz: 750 r/min / 60 mN·m (Torque Setting VoltageDC1.5 VAC※)
single-Phase 230 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.1 VAC※) - Permissible Inertia J: 60×10-4 kg·m2
- capacitor: Product name: CH40BFAUL, Capacity: 4 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 75
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous
single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC1.2 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz / 0.67 A / 128 W
single-Phase 200 VAC / 60 Hz / 0.69 A / 138 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 200 VAC / 50 Hz / 0.38 A / 47 W
single-Phase 200 VAC / 60 Hz / 0.42 A / 50 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 200 VAC / 60 Hz: 300 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 200 VAC / 50 Hz: 80 mN·m (Torque Setting VoltageDC1.6 VAC※)
single-Phase 200 VAC / 60 Hz: 85 mN·m (Torque Setting VoltageDC1.2 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 10 N·m
60 Hz: 10 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 4 N·m
60 Hz: 4.2 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 18 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 200 VAC / 60 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 200 VAC / 50Hz: 4 W (Torque Setting VoltageDC1.6 VAC※)
single-Phase 200 VAC / 60Hz: 4 W (Torque Setting VoltageDC1.2 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 750 r/min / 240 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 200 VAC / 60 Hz: 900 r/min / 220 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 200 VAC / 50 Hz: 750 r/min / 50 mN·m (Torque Setting VoltageDC1.6 VAC※)
single-Phase 200 VAC / 60 Hz: 900 r/min / 45 mN·m (Torque Setting VoltageDC1.2 VAC※) - Permissible Inertia J: 1875×10-4 kg·m2
- capacitor: Product name: CH45BFAUL, Capacity: 4.5 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 6
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous
single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC1.2 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz / 0.67 A / 128 W
single-Phase 200 VAC / 60 Hz / 0.69 A / 138 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 200 VAC / 50 Hz / 0.38 A / 47 W
single-Phase 200 VAC / 60 Hz / 0.42 A / 50 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 200 VAC / 60 Hz: 300 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 200 VAC / 50 Hz: 80 mN·m (Torque Setting VoltageDC1.6 VAC※)
single-Phase 200 VAC / 60 Hz: 85 mN·m (Torque Setting VoltageDC1.2 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 1.7 N·m
60 Hz: 1.5 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.39 N·m
60 Hz: 0.41 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 18 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 200 VAC / 60 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 200 VAC / 50Hz: 4 W (Torque Setting VoltageDC1.6 VAC※)
single-Phase 200 VAC / 60Hz: 4 W (Torque Setting VoltageDC1.2 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 750 r/min / 240 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 200 VAC / 60 Hz: 900 r/min / 220 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 200 VAC / 50 Hz: 750 r/min / 50 mN·m (Torque Setting VoltageDC1.6 VAC※)
single-Phase 200 VAC / 60 Hz: 900 r/min / 45 mN·m (Torque Setting VoltageDC1.2 VAC※) - Permissible Inertia J: 27×10-4 kg·m2
- capacitor: Product name: CH45BFAUL, Capacity: 4.5 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 60
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous
single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC1.2 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz / 0.67 A / 128 W
single-Phase 200 VAC / 60 Hz / 0.69 A / 138 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 200 VAC / 50 Hz / 0.38 A / 47 W
single-Phase 200 VAC / 60 Hz / 0.42 A / 50 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 200 VAC / 60 Hz: 300 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 200 VAC / 50 Hz: 80 mN·m (Torque Setting VoltageDC1.6 VAC※)
single-Phase 200 VAC / 60 Hz: 85 mN·m (Torque Setting VoltageDC1.2 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 10 N·m
60 Hz: 10 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 3.2 N·m
60 Hz: 3.4 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 18 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 200 VAC / 60 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 200 VAC / 50Hz: 4 W (Torque Setting VoltageDC1.6 VAC※)
single-Phase 200 VAC / 60Hz: 4 W (Torque Setting VoltageDC1.2 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 750 r/min / 240 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 200 VAC / 60 Hz: 900 r/min / 220 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 200 VAC / 50 Hz: 750 r/min / 50 mN·m (Torque Setting VoltageDC1.6 VAC※)
single-Phase 200 VAC / 60 Hz: 900 r/min / 45 mN·m (Torque Setting VoltageDC1.2 VAC※) - Permissible Inertia J: 1875×10-4 kg·m2
- capacitor: Product name: CH45BFAUL, Capacity: 4.5 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 60
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC1.5 VAC※: Continuous
single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC1.1 VAC※: Continuous
single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC1.5 VAC※: Continuous
single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC1.1 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz / 0.74 A / 151 W
single-Phase 220 VAC / 60 Hz / 0.72 A / 157 W
single-Phase 230 VAC / 50 Hz / 0.8 A / 169 W
single-Phase 230 VAC / 60 Hz / 0.76 A / 173 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 220 VAC / 50 Hz / 0.4 A / 54 W
single-Phase 220 VAC / 60 Hz / 0.39 A / 49 W
single-Phase 230 VAC / 50 Hz / 0.43 A / 60 W
single-Phase 230 VAC / 60 Hz / 0.41 A / 54 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 220 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 50 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 220 VAC / 50 Hz: 85 mN·m (Torque Setting VoltageDC1.5 VAC※)
single-Phase 220 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.1 VAC※)
single-Phase 230 VAC / 50 Hz: 85 mN·m (Torque Setting VoltageDC1.5 VAC※)
single-Phase 230 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.1 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 10 N·m
60 Hz: 10 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 3.4 N·m
60 Hz: 4 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 220 VAC / 60 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 50 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 60 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 220 VAC / 50Hz: 4.5 W (Torque Setting VoltageDC1.5 VAC※)
single-Phase 220 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.1 VAC※)
single-Phase 230 VAC / 50Hz: 4.5 W (Torque Setting VoltageDC1.5 VAC※)
single-Phase 230 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.1 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 750 r/min / 260 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 220 VAC / 60 Hz: 900 r/min / 220 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 230 VAC / 50 Hz: 750 r/min / 260 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 230 VAC / 60 Hz: 900 r/min / 220 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 220 VAC / 50 Hz: 750 r/min / 60 mN·m (Torque Setting VoltageDC1.5 VAC※)
single-Phase 220 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.1 VAC※)
single-Phase 230 VAC / 50 Hz: 750 r/min / 60 mN·m (Torque Setting VoltageDC1.5 VAC※)
single-Phase 230 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.1 VAC※) - Permissible Inertia J: 1875×10-4 kg·m2
- capacitor: Product name: CH40BFAUL, Capacity: 4 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 5
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC1.5 VAC※: Continuous
single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC1.1 VAC※: Continuous
single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC1.5 VAC※: Continuous
single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC1.1 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz / 0.74 A / 151 W
single-Phase 220 VAC / 60 Hz / 0.72 A / 157 W
single-Phase 230 VAC / 50 Hz / 0.8 A / 169 W
single-Phase 230 VAC / 60 Hz / 0.76 A / 173 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 220 VAC / 50 Hz / 0.4 A / 54 W
single-Phase 220 VAC / 60 Hz / 0.39 A / 49 W
single-Phase 230 VAC / 50 Hz / 0.43 A / 60 W
single-Phase 230 VAC / 60 Hz / 0.41 A / 54 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 220 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 50 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 60 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 220 VAC / 50 Hz: 85 mN·m (Torque Setting VoltageDC1.5 VAC※)
single-Phase 220 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.1 VAC※)
single-Phase 230 VAC / 50 Hz: 85 mN·m (Torque Setting VoltageDC1.5 VAC※)
single-Phase 230 VAC / 60 Hz: 100 mN·m (Torque Setting VoltageDC1.1 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 1.4 N·m
60 Hz: 1.4 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.34 N·m
60 Hz: 0.41 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 220 VAC / 60 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 50 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 60 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 220 VAC / 50Hz: 4.5 W (Torque Setting VoltageDC1.5 VAC※)
single-Phase 220 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.1 VAC※)
single-Phase 230 VAC / 50Hz: 4.5 W (Torque Setting VoltageDC1.5 VAC※)
single-Phase 230 VAC / 60Hz: 5.5 W (Torque Setting VoltageDC1.1 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 750 r/min / 260 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 220 VAC / 60 Hz: 900 r/min / 220 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 230 VAC / 50 Hz: 750 r/min / 260 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 230 VAC / 60 Hz: 900 r/min / 220 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 220 VAC / 50 Hz: 750 r/min / 60 mN·m (Torque Setting VoltageDC1.5 VAC※)
single-Phase 220 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.1 VAC※)
single-Phase 230 VAC / 50 Hz: 750 r/min / 60 mN·m (Torque Setting VoltageDC1.5 VAC※)
single-Phase 230 VAC / 60 Hz: 900 r/min / 60 mN·m (Torque Setting VoltageDC1.1 VAC※) - Permissible Inertia J: 18.7×10-4 kg·m2
- capacitor: Product name: CH40BFAUL, Capacity: 4 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 90 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 50
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous
single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC1.2 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz / 0.67 A / 128 W
single-Phase 200 VAC / 60 Hz / 0.69 A / 138 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 200 VAC / 50 Hz / 0.38 A / 47 W
single-Phase 200 VAC / 60 Hz / 0.42 A / 50 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 350 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 200 VAC / 60 Hz: 300 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 200 VAC / 50 Hz: 80 mN·m (Torque Setting VoltageDC1.6 VAC※)
single-Phase 200 VAC / 60 Hz: 85 mN·m (Torque Setting VoltageDC1.2 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 10 N·m
60 Hz: 9.9 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 2.6 N·m
60 Hz: 2.8 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 18 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 200 VAC / 60 Hz: 20 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 200 VAC / 50Hz: 4 W (Torque Setting VoltageDC1.6 VAC※)
single-Phase 200 VAC / 60Hz: 4 W (Torque Setting VoltageDC1.2 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 750 r/min / 240 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 200 VAC / 60 Hz: 900 r/min / 220 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 200 VAC / 50 Hz: 750 r/min / 50 mN·m (Torque Setting VoltageDC1.6 VAC※)
single-Phase 200 VAC / 60 Hz: 900 r/min / 45 mN·m (Torque Setting VoltageDC1.2 VAC※) - Permissible Inertia J: 1875×10-4 kg·m2
- capacitor: Product name: CH45BFAUL, Capacity: 4.5 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 4.0 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).