TOSHIBA
- Power & Power (Out):
15,0 kW; 31,7 A with overload ND 120% for 60s, 135% for 2s (standard)
11,0 kW; 23,5 A with overload HD 150% for 60s, 180% for 2s (heavy load) - Dimensions 211*554,5*232 mm (BxHxT *with DC choke)
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type
IP20...75 kW (HD) including NEMA terminal box, otherwise IP00 (optional...90 kW (HD) in IP54) - EMV filter class: Category C2 (EN61800-3) or A (EN55011)...37 kW (HD)
- Ambient temperature -10... +60°C (storage temperature -25...+70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
- Power & Power (Out):
160 kW; 302 A with overload ND 120% for 60s, 135% for 2s (standard)
132 kW; 250 A with overload HD 150% for 60s, 180% for 2s (heavy load) - Dimensions 300*850*383 mm (BxHxT *with DC choke)
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type
IP20...75 kW (HD) including NEMA terminal box, otherwise IP00 (optional...90 kW (HD) in IP54) - EMV filter class: EMC filter class: (IEC61800-3) Built-in filter C3-150m (2.5 kHz),
optional external filter C2-150m (2.5 kHz) - Ambient temperature -10... +60°C (storage temperature -25...+70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
- Power & Power (Out):
18,5 kW; 39,2 A with overload ND 120% for 60s, 135% for 2s (standard)
15,0 kW; 31,7 A with overload HD 150% for 60s, 180% for 2s (heavy load) - Dimensions 211*554,5*232 mm (BxHxT *with DC choke)
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type
IP20...75 kW (HD) including NEMA terminal box, otherwise IP00 (optional...90 kW (HD) in IP54) - EMV filter class: Category C2 (EN61800-3) or A (EN55011)...37 kW (HD)
- Ambient temperature -10... +60°C (storage temperature -25...+70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
- Power & Power (Out):
220 kW; 427 A with overload ND 120% for 60s, 135% for 2s (standard)
160 kW; 314 A with overload HD 150% for 60s, 180% for 2s (heavy load) - Dimensions 430*950 (1190)*377 mm (BxHxT) *with DC choke
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type
IP20...75 kW (HD) including NEMA terminal box, otherwise IP00 (optional...90 kW (HD) in IP54) - EMV filter class: Category C2 (EN61800-3) or A (EN55011)...37 kW (HD)
- Ambient temperature -10... +60°C (storage temperature -25...+70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
- Power & Power (Out):
22,0 kW; 46,3 A with overload ND 120% for 60s, 135% for 2s (standard)
18,5 kW; 39,2 A with overload HD 150% for 60s, 180% for 2s (heavy load) - Dimensions 211*554,5*232 mm (BxHxT *with DC choke)
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type
IP20...75 kW (HD) including NEMA terminal box, otherwise IP00 (optional...90 kW (HD) in IP54) - EMV filter class: Category C2 (EN61800-3) or A (EN55011)...37 kW (HD)
- Ambient temperature -10... +60°C (storage temperature -25...+70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
- Power & Power (Out):
250 kW; 481 A with overload ND 120% for 60s, 135% for 2s (standard)
200 kW; 387 A with overload HD 150% for 60s, 180% for 2s (heavy load) - Dimensions 585*950 (1190)*377 mm (BxHxT) *with DC choke
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type
IP20...75 kW (HD) including NEMA terminal box, otherwise IP00 (optional...90 kW (HD) in IP54) - EMV filter class: Category C2 (EN61800-3) or A (EN55011)...37 kW (HD)
- Ambient temperature -10... +60°C (storage temperature -25...+70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
- Power & Power (Out):
280 kW; 550 A with overload ND 120% for 60s, 135% for 2s (standard)
220 kW; 427 A with overload HD 150% for 60s, 180% for 2s (heavy load) - Dimensions 585*950 (1190)*377 mm (BxHxT) *with DC choke
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type
IP20...75 kW (HD) including NEMA terminal box, otherwise IP00 (optional...90 kW (HD) in IP54) - EMV filter class: Category C2 (EN61800-3) or A (EN55011)...37 kW (HD)
- Ambient temperature -10... +60°C (storage temperature -25...+70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
- Power & Power (Out):
30 kW; 61,5 A with overload ND 120% for 60s, 135% for 2s (standard)
22 kW; 46,3 A with overload HD 150% for 60s, 180% for 2s (heavy load) - Dimensions 226*693*268 mm (BxHxT) *with DC choke
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type
IP20...75 kW (HD) including NEMA terminal box, otherwise IP00 (optional...90 kW (HD) in IP54) - EMV filter class: Category C2 (EN61800-3) or A (EN55011)...37 kW (HD)
- Ambient temperature -10... +60°C (storage temperature -25...+70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
incl. SPS - Industry 4.0/IoT Ready with real-time clock
- Power & Power (Out):
315 kW; 616 A with overload ND 120% for 60s, 135% for 2s (standard)
280 kW; 550 A with overload HD 150% for 60s, 180% for 2s (heavy load) - Dimensions 585*950 (1190)*377 mm (BxHxT) *with DC choke
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type
IP20...75 kW (HD) including NEMA terminal box, otherwise IP00 (optional...90 kW (HD) in IP54) - EMV filter class: Category C2 (EN61800-3) or A (EN55011)...37 kW (HD)
- Ambient temperature -10... +60°C (storage temperature -25...+70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
- Power & Power (Out):
37,0 kW; 74,5 A with overload ND 120% for 60s, 135% for 2s (standard)
30,0 kW; 61,5 A with overload HD 150% for 60s, 180% for 2s (heavy load) - Dimensions 226*693*268 mm (BxHxT) *with DC choke
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type
IP20...75 kW (HD) including NEMA terminal box, otherwise IP00 (optional...90 kW (HD) in IP54) - EMV filter class: Category C2 (EN61800-3) or A (EN55011)...37 kW (HD)
- Ambient temperature -10... +60°C (storage temperature -25...+70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
- Power & Power (Out):
45,0 kW; 88,0 A with overload ND 120% for 60s, 135% for 2s (standard)
37,0 kW; 74,5 A with overload HD 150% for 60s, 180% for 2s (heavy load) - Dimensions 226*693*268 mm (BxHxT *with DC choke)
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type
IP20...75 kW (HD) including NEMA terminal box, otherwise IP00 (optional...90 kW (HD) in IP54) - EMV filter class: Category C2 (EN61800-3) or A (EN55011)...37 kW (HD)
- Ambient temperature -10... +60°C (storage temperature -25...+70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
- Power & Power (Out):
45 kW; 88 A with overload ND 120% for 60s, 135% for 2s (standard)
45 kW; 88 A with overload HD 150% for 60s, 180% for 2s (heavy load) - Dimensions 291*932*323 mm (BxHxT) *with DC choke
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type
IP20...75 kW (HD) including NEMA terminal box, otherwise IP00 (optional...90 kW (HD) in IP54) - EMV filter class: Category C2 (EN61800-3) or A (EN55011)...37 kW (HD)
- Ambient temperature -10... +60°C (storage temperature -25...+70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
- Power & Power (Out):
75,0 kW; 145 A with overload ND 120% for 60s, 135% for 2s (standard)
55,0 kW; 106 A with overload HD 150% for 60s, 180% for 2s (heavy load) - Dimensions 291*932*323 mm (BxHxT *with DC choke)
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type
IP20...75 kW (HD) including NEMA terminal box, otherwise IP00 (optional...90 kW (HD) in IP54) - EMV filter class: Category C2 (EN61800-3) or A (EN55011)...37 kW (HD)
- Ambient temperature -10... +60°C (storage temperature -25...+70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
- Power & Power (Out):
90,0 kW; 173 A with overload ND 120% for 60s, 135% for 2s (standard)
75,0 kW; 145 A with overload HD 150% for 60s, 180% for 2s (heavy load) - Dimensions 291*932*323 mm (BxHxT)
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type
IP20...75 kW (HD) including NEMA terminal box, otherwise IP00 (optional...90 kW (HD) in IP54) - EMV filter class: Category C2 (EN61800-3) or A (EN55011)...37 kW (HD)
- Ambient temperature -10... +60°C (storage temperature -25...+70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
- Power & Power (Out):
110 kW; 211 A with overload ND 120% for 60s, 135% for 2s (standard)
090 kW; 173 A with overload HD 150% for 60s, 180% for 2s (heavy load) - Dimensions 322*850*391 mm (BxHxT) *with DC choke
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type
IP20...75 kW (HD) including NEMA terminal box, otherwise IP00 (optional...90 kW (HD) in IP54) - EMV filter class: Category C2 (EN61800-3) or A (EN55011)...37 kW (HD)
- Ambient temperature -10... +60°C (storage temperature -25...+70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type...90 kW (HD) in IP55
- EMV filter class: Category C2 (EN61800-3) or A (EN55011)...37 kW (HD)
- Ambient temperature -10... +60°C (storage temperature -25... +70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
- Engine power: 7,50/11,50 kW (constant/quadratic torque)
- Output current: 33,0/48,4 A (constant/quadratic torque)
- Dimensions: HxBxT 220x150x170 mm
- Receipt: 230 V3AC (255…373V), 50/60 Hz
- Output: 0-Uin (V3AC); 0-500 Hz
- Overload 60s: 150/120 % (constant/quadratic torque)
- Protection type: IP20/JEM1030
- EMV filter class: A (EN55011) or category C2 (EN61800-3)
- Ambient temperature: -10 to +40(60)°C
- Clock frequency: 2.0-16.0 kHz
- Digital display: 4-digit (programmable)
• SPS functions Processes with up to 14 links in function plan logic
• Suitable for permanent magnet-excited motors
• Stable torque in generator operation
• Improved braking performance; Extended functionality for external brakes
• with PM motor drive for more effective energy saving
• Many interfaces available
• with PTC input
• Immediate start of work after engine connection
• Premium functions: Extended SPS; PM engines; servo-lock; STO function
- Engine power: 11,0/15,0 kW (constant/quadratic torque)
- Output current: 54,0/73,6 A (constant/quadratic torque)
- Dimensions: HxBxT 310x180x190 mm
- Receipt: 230 V3AC (255…373V), 50/60 Hz
- Output: 0-Uin (V3AC); 0-500 Hz
- Overload 60s: 150/120 % (constant/quadratic torque)
- Protection type: IP20/JEM1030
- EMV filter class: A (EN55011) or category C2 (EN61800-3)
- Ambient temperature: -10 to +40(60)°C
- Clock frequency: 2.0-16.0 kHz
- Digital display: 4-digit (programmable)
• SPS functions Processes with up to 14 links in function plan logic
• Suitable for permanent magnet-excited motors
• Stable torque in generator operation
• Improved braking performance; Extended functionality for external brakes
• with PM motor drive for more effective energy saving
• Many interfaces available
• with PTC input
• Immediate start of work after engine connection
• Premium functions: Extended SPS; PM engines; servo-lock; STO function
- Engine power: 15,0/18,5 kW (constant/quadratic torque)
- Output current: 66,0/81,4 A (constant/quadratic torque)
- Dimensions: HxBxT 310x180x190 mm
- Receipt: 230 V3AC (255…373V), 50/60 Hz
- Output: 0-Uin (V3AC); 0-500 Hz
- Overload 60s: 150/120 % (constant/quadratic torque)
- Protection type: IP20/JEM1030
- EMV filter class: A (EN55011) or category C2 (EN61800-3)
- Ambient temperature: -10 to +40(60)°C
- Clock frequency: 2.0-16.0 kHz
- Digital display: 4-digit (programmable)
• SPS functions Processes with up to 14 links in function plan logic
• Suitable for permanent magnet-excited motors
• Stable torque in generator operation
• Improved braking performance; Extended functionality for external brakes
• with PM motor drive for more effective energy saving
• Many interfaces available
• with PTC input
• Immediate start of work after engine connection
• Premium functions: Extended SPS; PM engines; servo-lock; STO function
- Engine power: 0,55/0,75 kW (constant/quadratic torque)
- Output current: 1,50/2,10 A (constant/quadratic torque)
- Dimensions: HxBxT 107x153x130 mm
- Receipt: 400 V3AC (323…550V), 50/60 Hz
- Output: 0-Uin (V3AC); 0-500 Hz
- Overload 60s: 150/120 % (constant/quadratic torque)
- Protection type: IP20/JEM1030
- EMV filter class: A (EN55011) or category C2 (EN61800-3)
- Ambient temperature: -10 to +40(60)°C
- Clock frequency: 2.0-16.0 kHz
- Digital display: 4-digit (programmable)
• SPS functions Processes with up to 14 links in function plan logic
• Suitable for permanent magnet-excited motors
• Stable torque in generator operation
• Improved braking performance; Extended functionality for external brakes
• with PM motor drive for more effective energy saving
• Many interfaces available
• with PTC input
• Immediate start of work after engine connection
• Premium functions: Extended SPS; PM engines; servo-lock; STO function