  • Engine power: 2,20/3,00 kW (constant/quadratic torque)
  • Output current: 11,00/12,00 A (constant/quadratic torque)
  • Dimensions: HxBxT 105x150x130 mm
  • Receipt: 400 V3AC (323…550V), 50/60 Hz
  • Output: 0-Uin (V3AC); 0-500 Hz
  • Overload 60s: 150/120 % (constant/quadratic torque)
  • Protection type: IP20/JEM1030
  • EMV filter class: A (EN55011) or category C2 (EN61800-3)
  • Ambient temperature: -10 to +40(60)°C
  • Clock frequency: 2.0-16.0 kHz
  • Digital display: 4-digit (programmable)

• Safe torque off function according to IEC61800 and IEC61508
• SPS functions Processes with up to 14 links in function plan logic
• Suitable for permanent magnet-excited motors
• Stable torque in generator operation
• Improved braking performance; Extended functionality for external brakes
• with PM motor drive for more effective energy saving
• Many interfaces available
• with PTC input
• Immediate start of work after engine connection
• Premium functions: Extended SPS; PM engines; servo-lock; STO function
SKU:
14973
Shipping weight:
2.08 kg
Item weight:
1.60 kg
404,00 € *
Available
Delivery time: 4 - 6 Workdays
  • Engine power: 1,50/2,20 kW (constant/quadratic torque)
  • Output current: 8,00/10,00 A (constant/quadratic torque)
  • Dimensions: HxBxT 105x150x130 mm
  • Receipt: 400 V3AC (323…550V), 50/60 Hz
  • Output: 0-Uin (V3AC); 0-500 Hz
  • Overload 60s: 150/120 % (constant/quadratic torque)
  • Protection type: IP20/JEM1030
  • EMV filter class: A (EN55011) or category C2 (EN61800-3)
  • Ambient temperature: -10 to +40(60)°C
  • Clock frequency: 2.0-16.0 kHz
  • Digital display: 4-digit (programmable)

• Safe torque off function according to IEC61800 and IEC61508
• SPS functions Processes with up to 14 links in function plan logic
• Suitable for permanent magnet-excited motors
• Stable torque in generator operation
• Improved braking performance; Extended functionality for external brakes
• with PM motor drive for more effective energy saving
• Many interfaces available
• with PTC input
• Immediate start of work after engine connection
• Premium functions: Extended SPS; PM engines; servo-lock; STO function
SKU:
13922
Shipping weight:
2.60 kg
Item weight:
2.00 kg
314,00 € *
Available
Delivery time: 4 - 6 Workdays
  • Engine power: 0,75/1,10 kW (constant/quadratic torque)
  • Output current: 4,80/5,50 A (constant/quadratic torque)
  • Dimensions: HxBxT 72x135x130 mm
  • Receipt: 230 V3AC (323…550V), 50/60 Hz
  • Output: 0-Uin (V3AC); 0-500 Hz
  • Overload 60s: 150/120 % (constant/quadratic torque)
  • Protection type: IP20/JEM1030
  • EMV filter class: A (EN55011) or category C2 (EN61800-3)
  • Ambient temperature: -10 to +40(60)°C
  • Clock frequency: 2.0-16.0 kHz
  • Digital display: 4-digit (programmable)

• Safe torque off function according to IEC61800 and IEC61508
• SPS functions Processes with up to 14 links in function plan logic
• Suitable for permanent magnet-excited motors
• Stable torque in generator operation
• Improved braking performance; Extended functionality for external brakes
• with PM motor drive for more effective energy saving
• Many interfaces available
• with PTC input
• Immediate start of work after engine connection
• Premium functions: Extended SPS; PM engines; servo-lock; STO function

SKU:
12951
Shipping weight:
1.43 kg
Item weight:
1.10 kg
264,00 € *
Available
Delivery time: 4 - 6 Workdays
  • Engine power: 0,37...0,55/0,75 kW (constant/quadratic torque)
  • Output current: 3,30/4,10 A (constant/quadratic torque)
  • Dimensions: HxBxT 72x120x130 mm
  • Receipt: 400 V3AC (323…550V), 50/60 Hz
  • Output: 0-Uin (V3AC); 0-500 Hz
  • Overload 60s: 150/120 % (constant/quadratic torque)
  • Protection type: IP20/JEM1030
  • EMV filter class: A (EN55011) or category C2 (EN61800-3)
  • Ambient temperature: -10 to +40(60)°C
  • Clock frequency: 2.0-16.0 kHz
  • Digital display: 4-digit (programmable)

• Safe torque off function according to IEC61800 and IEC61508
• SPS functions Processes with up to 14 links in function plan logic
• Suitable for permanent magnet-excited motors
• Stable torque in generator operation
• Improved braking performance; Extended functionality for external brakes
• with PM motor drive for more effective energy saving
• Many interfaces available
• with PTC input
• Immediate start of work after engine connection
• Premium functions: Extended SPS; PM engines; servo-lock; STO function

SKU:
13982
Shipping weight:
1.30 kg
Item weight:
1.00 kg
219,00 € *
Available
Delivery time: 3 - 5 Workdays
  • Engine power: 0,25/0,37 kW (constant/quadratic torque)
  • Output current: 1,50/1,90 A (constant/quadratic torque)
  • Dimensions: HxBxT 72x101x130 mm
  • Receipt: 400 V3AC (323…550V), 50/60 Hz
  • Output: 0-Uin (V3AC); 0-500 Hz
  • Overload 60s: 150/120 % (constant/quadratic torque)
  • Protection type: IP20/JEM1030
  • EMV filter class: A (EN55011) or category C2 (EN61800-3)
  • Ambient temperature: -10 to +40(60)°C
  • Clock frequency: 2.0-16.0 kHz
  • Digital display: 4-digit (programmable)

• Safe torque off function according to IEC61800 and IEC61508
• SPS functions Processes with up to 14 links in function plan logic
• Suitable for permanent magnet-excited motors
• Stable torque in generator operation
• Improved braking performance; Extended functionality for external brakes
• with PM motor drive for more effective energy saving
• Many interfaces available
• with PTC input
• Immediate start of work after engine connection
• Premium functions: Extended SPS; PM engines; servo-lock; STO function
SKU:
13388
Shipping weight:
1.17 kg
Item weight:
0.90 kg
189,00 € *
Available
Delivery time: 5 - 7 Workdays
  • Engine power 2,20 kW
  • Output current 10,0 A
  • Dimensions WxHxD 105x130x156 mm
  • Output voltage 50... 330 V3AC depending on input voltage
  • Output frequency 0,1... 400 Hz
  • Input voltage 170... 264 V1AC ±10%
  • input frequency 50... 60 Hz ±5%
  • Overload 150% for 60 seconds
  • Protection type IP20
  • Ambient temperature -10...+60°C13
  • Radio interference suppression filter IEC61800-3 C1 to 5 m, C2 to 10m motor line
  • incl. PID; RS485 interface
SKU:
AR6979
Shipping weight:
1.20 kg
Item weight:
1.00 kg
334,00 € *
Available
Delivery time: 3 - 5 Workdays
  • Engine power 1,50 kW
  • Output in appearance 3,00 kVA
  • Output current 7,5 A
  • Dimensions WxHxD 105x130x156 m
  • Output voltage 50... 330 V3AC depending on input voltage
  • Output frequency 0,1... 400 Hz
  • Input voltage 170... 264 V1AC ±10%
  • input frequency 50... 60 Hz ±5%
  • Overload 150% for 60 seconds
  • Protection type IP20
  • Ambient temperature -10...+60°C13
  • Radio interference suppression filter IEC61800-3 C1 to 5 m, C2 to 10m motor line
  • incl. PID; RS485 interface
SKU:
11217
Shipping weight:
1.20 kg
Item weight:
1.00 kg
289,00 € *
Available
Delivery time: 3 - 5 Workdays
  • Engine power 0,75 kW
  • Output in appearance 1,80 kVA
  • Output current 4,2 A
  • Dimensions WxHxD 72x130x102 m
  • Output voltage 50... 330 V3AC depending on input voltage
  • Output frequency 0,1... 400 Hz
  • Input voltage 170... 264 V1AC ±10%
  • input frequency 50... 60 Hz ±5%
  • Overload 150% for 60 seconds
  • Protection type IP20
  • Ambient temperature -10...+60°C13
  • Radio interference suppression filter IEC61800-3 C1 to 5 m, C2 to 10m motor line
  • incl. PID; RS485 interface
SKU:
11216
Shipping weight:
1.20 kg
Item weight:
1.00 kg
224,00 € *
Available
Delivery time: 3 - 5 Workdays
  • Engine power 0,55 kW
  • Output current 2,4 A
  • Dimensions WxHxD 72x130x121 mm
  • Output voltage 50... 330 V3AC depending on input voltage
  • Output frequency 0,1... 400 Hz
  • Input voltage 170... 264 V1AC ±10%
  • input frequency 50... 60 Hz ±5%
  • Overload 150% for 60 seconds
  • Protection type IP20
  • Ambient temperature -10...+60°C13
  • Radio interference suppression filter IEC61800-3 C1 to 5 m, C2 to 10m motor line
incl. PID; RS485 interface
SKU:
11094
Shipping weight:
1.00 kg
Item weight:
1.00 kg
189,00 € *
Available
Delivery time: 5 - 7 Workdays
  • Engine power 0,25 kW
  • Output in appearance 0,60 kVA
  • Output current 1,4 A
  • Dimensions WxHxD 72x130x102 m
  • Output voltage 50... 330 V3AC depending on input voltage
  • Output frequency 0,1... 400 Hz
  • Input voltage 170... 264 V1AC ±10%
  • input frequency 50... 60 Hz ±5%
  • Overload 150% for 60 seconds
  • Protection type IP20
  • Ambient temperature -10...+60°C13
  • Radio interference suppression filter IEC61800-3 C1 to 5 m, C2 to 10m motor line
  • incl. PID; RS485 interface
SKU:
11215
Shipping weight:
1.00 kg
Item weight:
1.00 kg
169,00 € *
Available
Delivery time: 3 - 5 Workdays

Items 1 - 10 of 10