Induction motors
Items 421 - 440 of 482
2IK6SB-75S general-purpose motor WK2 series
• Description of Specification Items
- Frame Size: 60 mm
- Output Power: 6 W
- series: World K series
- Type: With Terminal Box
- Gear Ratio: 90
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 0.081 A
Three-Phase 200 VAC / 60 Hz / 0.072 A
Three-Phase 220 VAC / 60 Hz / 0.076 A
Three-Phase 230 VAC / 60 Hz / 0.079 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 49 mN·m
Three-Phase 200 VAC / 60 Hz: 41 mN·m
Three-Phase 220 VAC / 60 Hz: 41 mN·m
Three-Phase 230 VAC / 60 Hz: 41 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 49 mN·m / 1200 r/min
Three-Phase 200 VAC / 60 Hz: 41 mN·m / 1400 r/min
Three-Phase 220 VAC / 60 Hz: 41 mN·m / 1500 r/min
Three-Phase 230 VAC / 60 Hz: 41 mN·m / 1500 r/min - The Speed When Installing gearhead: Three-Phase 200 VAC / 50 Hz: 16.6 r/min
Three-Phase 200 VAC / 60 Hz: 20 r/min
Three-Phase 220 VAC / 60 Hz: 20 r/min
Three-Phase 230 VAC / 60 Hz: 20 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 200 VAC / 50 Hz: 2.9 N·m
Three-Phase 200 VAC / 60 Hz: 2.4 N·m
Three-Phase 220 VAC / 60 Hz: 2.4 N·m
Three-Phase 230 VAC / 60 Hz: 2.4 N·m - Permissible Inertia J: 155×10-4 kg·m2
- capacitor: -
- Overheat Protective Device Type: Impedance protected
- Mass: 1.3 kg (With gearhead)
• UL/CSA, CCC, CE mark apply to the Motor.
• Certification regarding various safety standards is acquired for the product name on the motor nameplate.
• Certification regarding various safety standards is acquired for the product name on the motor nameplate.
• The speed when the gearhead is installed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less, depending on the load.
- Output power: 150 W
- Speed 50 Hz: 3000 min-1, 60 Hz: 3600
- Engine frame size: 90 mm
- Degree of protection IP20
- RoHS compliant
- incl. a protective cap codenser for AC motors
- incl. fixing screws, washers and nuts
- Depending on the load, the actual speed 2-20 % is lower than the value listed here.
5IK60RGU-AWJ speed-control motor WK series
The Product Name Listed on the Motor Nameplate: 5IK60RGU-CW
The product name is suffixed with a symbol indicating the type of capacitor.
J: single-phase 200 VAC capacitor is included. (This product)
E: single-phase 220/230 VAC capacitors are Included. (5IK60RGU-CWE)
- Frame Size: 90 mm
- Output Power: 60 W
- Time Rating: Continuous
- Motor Type: speed-control motor, Induction Motor
- Shaft/Gear Type: Pinion Shaft Type
- Type: Lead Wire Type
- capacitor: Product Name: CH50BFAUL, Capacitance: 5.0 µF, Rated Voltage: 450 VAC
- Power Supply Input Frequency: single-Phase 200 VAC 50/60 Hz
- Overheat Protective Device Type: Thermal protector
- Mass: 3.2 kg
The Product Name Listed on the Motor Nameplate: 5IK60RA-AW
The product name is suffixed with a symbol indicating the type of capacitor.
U: capacitor for single-phase 110/115 VAC Is Included (Products)
J: single-phase 100 VAC capacitor is Included. (5IK60RA-AWJ)
- Frame Size: 90 mm
- Output Power: 60 W
- Time Rating: Continuous
- Motor Type: speed-control motor, Induction Motor
- Shaft/Gear Type: Round Shaft Type
- Type: Lead Wire Type
- capacitor: Capacity: 18 µF、Rated voltage: 250 VAC
- Power Supply Input Frequency: single-Phase 110/115VAC 60 Hz
- Overheat Protective Device Type: Thermal protector
5IK60RGU-AWU speed-control motor WK series
5IK60RA-CWE speed-control motor WK series
5IK60RGU-CWE speed-control motor WK series
7IK200VAS-JS3T2 general-purpose motor K2S series
- Frame Size: 110 mm
- Output Power: 200 W
- series: KIIS series
- Type: With Terminal Box
- Shaft/Gear Type: Pinion Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Rotation Direction: Depends on the combination gearhead.
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 1.10 A
Three-Phase 200 VAC / 60 Hz / 1.00 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1690 mN·m
Three-Phase 200 VAC / 60 Hz: 1410 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1350 mN·m / 1420 r/min
Three-Phase 200 VAC / 60 Hz: 1130 mN·m / 1700 r/min - Mass: 5.4 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
7IK200VAS-ES3T2 general-purpose motor K2S series
- Frame Size: 110 mm
- Output Power: 200 W
- series: KIIS series
- Type: With Terminal Box
- Shaft/Gear Type: Pinion Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Rotation Direction: Depends on the combination gearhead.
- Voltage/ Frequency/ Current: Three-Phase 220 VAC / 50 Hz / 1.00 A
Three-Phase 220 VAC / 60 Hz / 0.90 A
Three-Phase 230 VAC / 50 Hz / 1.02 A
Three-Phase 230 VAC / 60 Hz / 0.89 A
Three-Phase 240 VAC / 50 Hz / 1.06 A
Three-Phase 240 VAC / 60 Hz / 0.90 A - Starting Torque (Motor Shaft): Three-Phase 220 VAC / 50 Hz: 1690 mN·m
Three-Phase 220 VAC / 60 Hz: 1410 mN·m
Three-Phase 230 VAC / 50 Hz: 1690 mN·m
Three-Phase 230 VAC / 60 Hz: 1410 mN·m
Three-Phase 240 VAC / 50 Hz: 1690 mN·m
Three-Phase 240 VAC / 60 Hz: 1410 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 220 VAC / 50 Hz: 1350 mN·m / 1420 r/min
Three-Phase 220 VAC / 60 Hz: 1130 mN·m / 1700 r/min
Three-Phase 230 VAC / 50 Hz: 1350 mN·m / 1420 r/min
Three-Phase 230 VAC / 60 Hz: 1130 mN·m / 1700 r/min
Three-Phase 240 VAC / 50 Hz: 1350 mN·m / 1420 r/min
Three-Phase 240 VAC / 60 Hz: 1130 mN·m / 1700 r/min - Mass: 5.4 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
7IK200VAS-EU3T2 general-purpose motor K2S series
- Frame Size: 110 mm
- Output Power: 200 W
- series: KIIS series
- Type: With Terminal Box
- Shaft/Gear Type: Pinion Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Rotation Direction: Depends on the combination gearhead.
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.52 A
Three-Phase400 VAC / 50 Hz / 0.56 A
Three-Phase400 VAC / 60 Hz / 0.51 A
Three-Phase415 VAC / 50 Hz / 0.57 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1400 mN·m
Three-Phase 380 VAC / 60 Hz: 1300 mN·m
Three-Phase 400 VAC / 50 Hz: 1400 mN·m
Three-Phase 400 VAC / 60 Hz: 1300 mN·m
Three-Phase 415 VAC / 50 Hz: 1400 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1350 mN·m / 1420 r/min
Three-Phase 380 VAC / 60 Hz: 1130 mN·m / 1700 r/min
Three-Phase 400 VAC / 50 Hz: 1350 mN·m / 1420 r/min
Three-Phase 400 VAC / 60 Hz: 1130 mN·m / 1700 r/min
Three-Phase 415 VAC / 50 Hz: 1350 mN·m / 1420 r/min - Mass: 5.4 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
- Output power: 60 W
- Speed: 1500 min-1
- Motor frame size: 90 mm
Optional with holding brake
Degree of protection IP20
- RoHS compliant
- incl. a codenser with protective cap for AC motors
Includes fixing screws, washers and nuts
The engine speed is calculated by synchronous engine speed (50 Hz): 1500 min-1, 60 Hz: 1800 min-1) is divided by the transmission reduction.
Depending on the load, the actual speed 2-20 % is lower than the value listed here.
- Speed: 1500 min-1
- Motor frame size: 90 mm
Optional with holding brake
Degree of protection IP20
- RoHS compliant
- incl. a codenser with protective cap for AC motors
Includes fixing screws, washers and nuts
The engine speed is calculated by synchronous engine speed (50 Hz): 1500 min-1, 60 Hz: 1800 min-1) is divided by the transmission reduction.
Depending on the load, the actual speed 2-20 % is lower than the value listed here.
- Output power: 60 W
- Speed: 1500 min-1
- Motor frame size: 90 mm
Optional with holding brake
Degree of protection IP20
- RoHS compliant
- incl. a codenser with protective cap for AC motors
Includes fixing screws, washers and nuts
The engine speed is calculated by synchronous engine speed (50 Hz): 1500 min-1, 60 Hz: 1800 min-1) is divided by the transmission reduction.
Depending on the load, the actual speed 2-20 % is lower than the value listed here.
- Speed: 1500 min-1
- Motor frame size: 90 mm
Optional with holding brake
Degree of protection IP20
- RoHS compliant
- incl. a codenser with protective cap for AC motors
Includes fixing screws, washers and nuts
The engine speed is calculated by synchronous engine speed (50 Hz): 1500 min-1, 60 Hz: 1800 min-1) is divided by the transmission reduction.
Depending on the load, the actual speed 2-20 % is lower than the value listed here.
7IK200VJS3T2-10S general-purpose motor K2S series
- Frame Size: 110 mm
- Output Power: 200 W
- series: KIIS series
- Type: With Terminal Box
- Shaft/Gear Type: Parallel Shaft Combination Type
- Gear Ratio: 15
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 1.10 A
Three-Phase 200 VAC / 60 Hz / 1.00 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1690 mN·m
Three-Phase 200 VAC / 60 Hz: 1410 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1350 mN·m / 1420 r/min
Three-Phase 200 VAC / 60 Hz: 1130 mN·m / 1700 r/min - The Speed When Installing gearhead: Three-Phase 200 VAC / 50 Hz: 100 r/min
Three-Phase 200 VAC / 60 Hz: 120 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 200 VAC / 50 Hz: 18.2 N·m
Three-Phase 200 VAC / 60 Hz: 15.3 N·m - Permissible Inertia J: 1000×10-4 kg·m2 (Instantaneous Stop: 450×10-4 kg·m2)
- Mass: 7.3 kg
• The speed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is a maximum of 10% less, depending on the load.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
7IK200VJS3T2-20S general-purpose motor K2S series