GD350A Accessories
Additional notes:
On page 8: P16.32 and following for PZD mapping
On page 40: P15.43=1 switches to bitwise communication (only FU firmware 3.02.XX)
The FU firmware 1.01 and 1.05 can only communicate byte-wise.
Profinet IP addresses in FU firmware 1.0X on P16.02 to P16.05
Profinet IP addresses in FU firmware 3.02 on P16.58 to P16.61
In the documentation attached you will also find a parameter example, as well as Profinet simulator example commands.
• Applies to 24V-OC-Geber
• Applies to 24V-Push-Pull-Geber
• Applies to 5V-Differenzialgeber
• Supports orthogonal input A, B, Z
Supports frequency-divided output A, B, Z
Supports the input of the pulse sequence setpoint value
The expansion card can be installed in one of the card slots SLOT1, SLOT2 and SLOT3. The VFD models 5R5G/7R5P and below can be configured with two expansion cards at the same time, the models 7R5G/011P and higher can be configured with three expansion cards.
To ensure high interference resistance during the control, you must use a shielding wire in the transmitter cable and ground the two ends of the shielding wire, i.e. h connect the shielding layer on the motor side to the motor housing and on the PG card side to the PE terminal.