Skip to main content Skip to search Skip to navigation

3AC ATEX motors KEMM


Ex2SIE-63-4B – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.

Ex-marking II 2G Ex eb IIC T3 Gb
Voltage 3~ 400 V / 50 Hz
Frequency inverter operation No
Rated power output 0,18 kW (0,25 HP)
Rated speed 1380 min⁻¹
Rated torque 1,2 Nm
Efficiency/cos φ 67,5% / 0,70
Rated current (400 V) 0,55 A
Locked Rotor Torque Ratio (T)L/TN) 2,50
Locked Rotor Current Ratio (I)L/IN) 3,80
Breakdown Torque Ratio (T)BB/TN) 2,50
Moment of Inertia J kgm2
Time tEE (T3) 80 s
Ball bearing (DE / NDE) 6202 2Z C3 / 6202 2Z C3
Motorhousing Aluminium
Wave (D/E) 11 mm / 23 mm
SKU:
Ex2SIE-63-4B
Variations in:
  • Design
  • Protection class
  • Frequency
  • Execution
Shipping weight:
7.93 kg
Item weight:
6.10 kg
Price on request
Available

Ex3SIE-100L-2 – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.

Ex-marking II 2G Ex eb IIC T3 Gb
Voltage 3~ 400 V / 50 Hz
Frequency inverter operation No
Rated power output 3,00 kW (4,00 HP)
Rated speed 2915 min⁻¹
Rated torque 9,8 Nm
Efficiency/cos φ 87,1% / 0,85
Rated current (400 V) 5,80 A
Locked Rotor Torque Ratio (T)L/TN) 3,00
Locked Rotor Current Ratio (I)L/IN) 7,80
Breakdown Torque Ratio (T)BB/TN) 4,10
Moment of Inertia J 0,004 kgm2
Time tEE (T3) 14 s
Ball bearing (DE / NDE) 6206 2Z C3 / 6206 2Z C3
Motorhousing Aluminium
Wave (D/E) 28 mm / 60 mm
SKU:
Ex3SIE-100L-2
Variations in:
  • Design
  • Protection class
  • Frequency
  • Execution
Shipping weight:
32.50 kg
Item weight:
25.00 kg
Price on request
Available

Ex3SIE-100L-6 – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.

Ex-marking II 2G Ex eb IIC T3 Gb
Voltage 3~ 400 V / 50 Hz
Frequency inverter operation No
Rated power output 1,50 kW (2,00 HP)
Rated speed 960 min⁻¹
Rated torque 14,9 Nm
Efficiency/cos φ 82,5% / 0,74
Rated current (400 V) 3,50 A
Locked Rotor Torque Ratio (T)L/TN) 2,00
Locked Rotor Current Ratio (I)L/IN) 5,50
Breakdown Torque Ratio (T)BB/TN) 2,70
Moment of Inertia J 0,010 kgm2
Time tEE (T3) 24 s
Ball bearing (DE / NDE) 6206 2Z C3 / 6206 2Z C3
Motorhousing Aluminium
Wave (D/E) 28 mm / 60 mm
SKU:
Ex3SIE-100L-6
Variations in:
  • Design
  • Protection class
  • Frequency
  • Execution
Shipping weight:
30.55 kg
Item weight:
23.50 kg
Price on request
Available

Ex3SIE-112M-2 – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.

Ex-marking II 2G Ex eb IIC T3 Gb
Voltage 3~ 400 V / 50 Hz
Frequency inverter operation No
Rated power output 4,00 kW (5,50 HP)
Rated speed 2925 min⁻¹
Rated torque 13,0 Nm
Efficiency/cos φ 88,1% / 0,89
Rated current (400 V) 7,40 A
Locked Rotor Torque Ratio (T)L/TN) 2,30
Locked Rotor Current Ratio (I)L/IN) 8,40
Breakdown Torque Ratio (T)BB/TN) 3,20
Moment of Inertia J 0,007 kgm2
Time tEE (T3) 14 s
Ball bearing (DE / NDE) 6306 2Z C3 / 6306 2Z C3
Motorhousing Aluminium
Wave (D/E) 28 mm / 60 mm
SKU:
Ex3SIE-112M-2
Variations in:
  • Design
  • Protection class
  • Frequency
  • Execution
Shipping weight:
46.15 kg
Item weight:
35.50 kg
Price on request
Available

Ex3SIE-112M-4 – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.

Ex-marking II 2G Ex eb IIC T3 Gb
Voltage 3~ 400 V / 50 Hz
Frequency inverter operation No
Rated power output 4,00 kW (5,50 HP)
Rated speed 1455 min⁻¹
Rated torque 26,3 Nm
Efficiency/cos φ 88,6% / 0,80
Rated current (400 V) 8,10 A
Locked Rotor Torque Ratio (T)L/TN) 2,10
Locked Rotor Current Ratio (I)L/IN) 6,90
Breakdown Torque Ratio (T)BB/TN) 3,00
Moment of Inertia J 0,011 kgm2
Time tEE (T3) 12 s
Ball bearing (DE / NDE) 6306 2Z C3 / 6306 2Z C3
Motorhousing Aluminium
Wave (D/E) 28 mm / 60 mm
SKU:
Ex3SIE-112M-4
Variations in:
  • Design
  • Protection class
  • Frequency
  • Execution
Shipping weight:
53.95 kg
Item weight:
41.50 kg
Price on request
Available

Ex3SIE-112M-6 – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.

Ex-marking II 2G Ex eb IIC T3 Gb
Voltage 3~ 400 V / 50 Hz
Frequency inverter operation No
Rated power output 2,20 kW (3,00 HP)
Rated speed 965 min⁻¹
Rated torque 21,8 Nm
Efficiency/cos φ 84,3% / 0,76
Rated current (400 V) 5,00 A
Locked Rotor Torque Ratio (T)L/TN) 2,10
Locked Rotor Current Ratio (I)L/IN) 6,40
Breakdown Torque Ratio (T)BB/TN) 2,60
Moment of Inertia J 0,018 kgm2
Time tEE (T3) 23 s
Ball bearing (DE / NDE) 6306 2Z C3 / 6306 2Z C3
Motorhousing Aluminium
Wave (D/E) 28 mm / 60 mm
SKU:
Ex3SIE-112M-6
Variations in:
  • Design
  • Protection class
  • Frequency
  • Execution
Shipping weight:
44.20 kg
Item weight:
34.00 kg
Price on request
Available

Ex3SIE-132M-4 – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.

Ex-marking II 2G Ex eb IIC T3 Gb
Voltage 3~ 400 V / 50 Hz
Frequency inverter operation No
Rated power output 7,50 kW (10,00 HP)
Rated speed 1465 min⁻¹
Rated torque 49,1 Nm
Efficiency/cos φ 90,4% / 0,83
Rated current (400 V) 14,40 A
Locked Rotor Torque Ratio (T)L/TN) 2,90
Locked Rotor Current Ratio (I)L/IN) 9,50
Breakdown Torque Ratio (T)BB/TN) 3,80
Moment of Inertia J 0,042 kgm2
Time tEE (T3) 12 s
Ball bearing (DE / NDE) 6308 2Z C3 / 6308 2Z C3
Motorhousing Aluminium
Wave (D/E) 38 mm / 80 mm
SKU:
Ex3SIE-132M-4
Variations in:
  • Design
  • Protection class
  • Frequency
  • Execution
Shipping weight:
87.10 kg
Item weight:
67.00 kg
Price on request
Available

Ex3SIE-132S-4 – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.

Ex-marking II 2G Ex eb IIC T3 Gb
Voltage 3~ 400 V / 50 Hz
Frequency inverter operation No
Rated power output 5,50 kW (7,50 HP)
Rated speed 1465 min⁻¹
Rated torque 35,7 Nm
Efficiency/cos φ 89,6% / 0,85
Rated current (400 V) 10,40 A
Locked Rotor Torque Ratio (T)L/TN) 2,50
Locked Rotor Current Ratio (I)L/IN) 9,20
Breakdown Torque Ratio (T)BB/TN) 3,40
Moment of Inertia J 0,036 kgm2
Time tEE (T3) 14 s
Ball bearing (DE / NDE) 6308 2Z C3 / 6308 2Z C3
Motorhousing Aluminium
Wave (D/E) 38 mm / 80 mm
SKU:
Ex3SIE-132S-4
Variations in:
  • Design
  • Protection class
  • Frequency
  • Execution
Shipping weight:
81.90 kg
Item weight:
63.00 kg
Price on request
Available

Ex3SIE-132S-6 – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.

Ex-marking II 2G Ex eb IIC T3 Gb
Voltage 3~ 400 V / 50 Hz
Frequency inverter operation No
Rated power output 3,00 kW (4,00 HP)
Rated speed 965 min⁻¹
Rated torque 29,7 Nm
Efficiency/cos φ 87,0% / 0,81
Rated current (400 V) 6,20 A
Locked Rotor Torque Ratio (T)L/TN) 2,20
Locked Rotor Current Ratio (I)L/IN) 6,60
Breakdown Torque Ratio (T)BB/TN) 2,90
Moment of Inertia J 0,044 kgm2
Time tEE (T3) 17 s
Ball bearing (DE / NDE) 6308 2Z C3 / 6308 2Z C3
Motorhousing Aluminium
Wave (D/E) 38 mm / 80 mm
SKU:
Ex3SIE-132S-6
Variations in:
  • Design
  • Protection class
  • Frequency
  • Execution
Shipping weight:
70.20 kg
Item weight:
54.00 kg
Price on request
Available

Ex3SIE-160L-2 – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.

Ex-marking II 2G Ex eb IIC T3 Gb
Voltage 3~ 400 V / 50 Hz
Frequency inverter operation No
Rated power output 18,50 kW (25,00 HP)
Rated speed 2950 min⁻¹
Rated torque 59,9 Nm
Efficiency/cos φ 92,4% / 0,87
Rated current (400 V) 33,20 A
Locked Rotor Torque Ratio (T)L/TN) 2,70
Locked Rotor Current Ratio (I)L/IN) 8,80
Breakdown Torque Ratio (T)BB/TN) 4,00
Moment of Inertia J 0,072 kgm2
Time tEE (T3) 6 s
Ball bearing (DE / NDE) 6309 2Z C3 / 6309 2Z C3
Motorhousing Aluminium
Wave (D/E) 42 mm / 110 mm
SKU:
Ex3SIE-160L-2
Variations in:
  • Design
  • Protection class
  • Frequency
  • Execution
Shipping weight:
137.80 kg
Item weight:
106.00 kg
Price on request
Available