3AC ATEX motors KEMM
Ex3SIE-132M-4 – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.
| Ex-marking | II 2G Ex eb IIC T3 Gb |
|---|---|
| Voltage | 3~ 400 V / 50 Hz |
| Frequency inverter operation | No |
| Rated power output | 7,50 kW (10,00 HP) |
| Rated speed | 1465 min⁻¹ |
| Rated torque | 49,1 Nm |
| Efficiency/cos φ | 90,4% / 0,83 |
| Rated current (400 V) | 14,40 A |
| Locked Rotor Torque Ratio (T)L/TN) | 2,90 |
| Locked Rotor Current Ratio (I)L/IN) | 9,50 |
| Breakdown Torque Ratio (T)BB/TN) | 3,80 |
| Moment of Inertia J | 0,042 kgm2 |
| Time tEE (T3) | 12 s |
| Ball bearing (DE / NDE) | 6308 2Z C3 / 6308 2Z C3 |
| Motorhousing | Aluminium |
| Wave (D/E) | 38 mm / 80 mm |
Ex3SIE-132M-6A – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.
| Ex-marking | II 2G Ex eb IIC T3 Gb |
|---|---|
| Voltage | 3~ 400 V / 50 Hz |
| Frequency inverter operation | No |
| Rated power output | 4,00 kW (5,50 HP) |
| Rated speed | 965 min⁻¹ |
| Rated torque | 39,8 Nm |
| Efficiency/cos φ | 88,0% / 0,81 |
| Rated current (400 V) | 8,10 A |
| Locked Rotor Torque Ratio (T)L/TN) | 2,30 |
| Locked Rotor Current Ratio (I)L/IN) | 7,00 |
| Breakdown Torque Ratio (T)BB/TN) | 3,00 |
| Moment of Inertia J | 0,058 kgm2 |
| Time tEE (T3) | 19 s |
| Ball bearing (DE / NDE) | 6308 2Z C3 / 6308 2Z C3 |
| Motorhousing | Aluminium |
| Wave (D/E) | 38 mm / 80 mm |
Ex3SIE-132M-6B – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.
| Ex-marking | II 2G Ex eb IIC T3 Gb |
|---|---|
| Voltage | 3~ 400 V / 50 Hz |
| Frequency inverter operation | No |
| Rated power output | 5,50 kW (7,50 HP) |
| Rated speed | 960 min⁻¹ |
| Rated torque | 54,7 Nm |
| Efficiency/cos φ | 88,0% / 0,81 |
| Rated current (400 V) | 11,10 A |
| Locked Rotor Torque Ratio (T)L/TN) | 2,40 |
| Locked Rotor Current Ratio (I)L/IN) | 6,90 |
| Breakdown Torque Ratio (T)BB/TN) | 3,10 |
| Moment of Inertia J | 0,064 kgm2 |
| Time tEE (T3) | 15 s |
| Ball bearing (DE / NDE) | 6308 2Z C3 / 6308 2Z C3 |
| Motorhousing | Aluminium |
| Wave (D/E) | 38 mm / 80 mm |
Ex3SIE-132S-2A – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.
| Ex-marking | II 2G Ex eb IIC T3 Gb |
|---|---|
| Voltage | 3~ 400 V / 50 Hz |
| Frequency inverter operation | No |
| Rated power output | 5,50 kW (7,50 HP) |
| Rated speed | 2940 min⁻¹ |
| Rated torque | 17,9 Nm |
| Efficiency/cos φ | 89,2% / 0,89 |
| Rated current (400 V) | 10,00 A |
| Locked Rotor Torque Ratio (T)L/TN) | 2,60 |
| Locked Rotor Current Ratio (I)L/IN) | 8,90 |
| Breakdown Torque Ratio (T)BB/TN) | 3,40 |
| Moment of Inertia J | 0,014 kgm2 |
| Time tEE (T3) | 12 s |
| Ball bearing (DE / NDE) | 6308 2Z C3 / 6308 2Z C3 |
| Motorhousing | Aluminium |
| Wave (D/E) | 38 mm / 80 mm |
Ex3SIE-132S-2B – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.
| Ex-marking | II 2G Ex eb IIC T3 Gb |
|---|---|
| Voltage | 3~ 400 V / 50 Hz |
| Frequency inverter operation | No |
| Rated power output | 7,50 kW (10,00 HP) |
| Rated speed | 2940 min⁻¹ |
| Rated torque | 24,4 Nm |
| Efficiency/cos φ | 90,1% / 0,90 |
| Rated current (400 V) | 13,30 A |
| Locked Rotor Torque Ratio (T)L/TN) | 2,80 |
| Locked Rotor Current Ratio (I)L/IN) | 8,90 |
| Breakdown Torque Ratio (T)BB/TN) | 3,80 |
| Moment of Inertia J | 0,017 kgm2 |
| Time tEE (T3) | 8 s |
| Ball bearing (DE / NDE) | 6308 2Z C3 / 6308 2Z C3 |
| Motorhousing | Aluminium |
| Wave (D/E) | 38 mm / 80 mm |
Ex3SIE-132S-4 – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.
| Ex-marking | II 2G Ex eb IIC T3 Gb |
|---|---|
| Voltage | 3~ 400 V / 50 Hz |
| Frequency inverter operation | No |
| Rated power output | 5,50 kW (7,50 HP) |
| Rated speed | 1465 min⁻¹ |
| Rated torque | 35,7 Nm |
| Efficiency/cos φ | 89,6% / 0,85 |
| Rated current (400 V) | 10,40 A |
| Locked Rotor Torque Ratio (T)L/TN) | 2,50 |
| Locked Rotor Current Ratio (I)L/IN) | 9,20 |
| Breakdown Torque Ratio (T)BB/TN) | 3,40 |
| Moment of Inertia J | 0,036 kgm2 |
| Time tEE (T3) | 14 s |
| Ball bearing (DE / NDE) | 6308 2Z C3 / 6308 2Z C3 |
| Motorhousing | Aluminium |
| Wave (D/E) | 38 mm / 80 mm |
Ex3SIE-132S-6 – three-phase induction motor in explosion-proof version (ATEX), protection class IP55, cooling class IC411.
| Ex-marking | II 2G Ex eb IIC T3 Gb |
|---|---|
| Voltage | 3~ 400 V / 50 Hz |
| Frequency inverter operation | No |
| Rated power output | 3,00 kW (4,00 HP) |
| Rated speed | 965 min⁻¹ |
| Rated torque | 29,7 Nm |
| Efficiency/cos φ | 87,0% / 0,81 |
| Rated current (400 V) | 6,20 A |
| Locked Rotor Torque Ratio (T)L/TN) | 2,20 |
| Locked Rotor Current Ratio (I)L/IN) | 6,60 |
| Breakdown Torque Ratio (T)BB/TN) | 2,90 |
| Moment of Inertia J | 0,044 kgm2 |
| Time tEE (T3) | 17 s |
| Ball bearing (DE / NDE) | 6308 2Z C3 / 6308 2Z C3 |
| Motorhousing | Aluminium |
| Wave (D/E) | 38 mm / 80 mm |