Speed-controller clearance stock


Sale 19%
Frequency inverter vector-controlled for synchronous and asynchronous motors also usable as an supply/regenerative module with a power up to 1,4 kW - Motor power 0,75 kW - Operation with higher overload 150% for 60 s -2,1 A - Motor power 1,10 kW - low overload operation 110% for 60 s -2,8 A Built-in device: IP20; IP54 in through-mounted Grid connection: 380-480 V3AC ±10%, 48…65 Hz Engine connection: 0-Uin V3AC; 0-550 CL/0-550 (OL) Hz Ambient temperature: -10 to +40(50)° C., atmospheric humidity <93% without condensation max. Überlast: 150% for 60 sec. (OL) / bzw. 120% for 60 sec. (OL); 175% (CL) switching frequency: einstellbar 3 bis 16 kHz (ohne power derating) safety function: "safe stop" nach EN 954-1 Kat. 3 Smart Card: im accessories - zur Sicherung und Übertragung der Parameter Schnittstelle: RS485 mit RJ45 connector (2-wire) Bremsschalter: eingebaut, resistance > 74 Ohm (Optional) Net filter: EMV filter class according to EN61800-3 Dimensions BxHxT: 100 x 368 x 219 mm incl. PID controllers, with integrated adjustable DC brake; programmable digital inputs 5x for start/stop/rotation direction, etc.; analogue input for poti etc.; programmable digital output 3x + relay outputs; programmable analog output 2x; with universal encoder input with 14 possible signal types up to 400 kHz; Switching to negative or positive logic 24VDC 5 different operating modes can be selected via parameters: Open loop, U/f control without speed sensor - Open loop, extended vector control without speed sensor Closed loop, vector control with speed sensor - Regulation for brushless servomotors - feedback with reactive power control Functions: output frequency (rotational speed) can be adjusted continuously via the optional external potentiometer, i.e., speeds up to max. 180000 1/min; torque/current limitation adjustable; Maximum voltage adjustable; emergency stop; two acceleration and braking times up to 3.600 s (one hour) adjustable with different ramp shapes; can be controlled with 15 different fixed frequencies via BCD coding of the digital inputs; engine trapping function; motor pokies; any frequency-proportional speed can be displayed; Type-in mode (JOG function) the nominal frequency value can also be controlled via 0-10V or 0(4)-20mA; setpoint/frequency allocation; frequency bands can be masked; scalable SPS with pluggable SM modules Option: As standard, the UniDrive is delivered without a control panel, this reduces the costs for multi-axis applications (plugged in during operation IP54); open to various field buses; additional encoder input; placing in service software; SolutionsSoftware (for winders, flying saw, pump control); Addition I/O modulus; external braking resistance (integrated at 1+2 size); potentiometer 10 kOhm lin.’; installation in IP65-enclosure; output filter; DC choke; SM application modules with synchonization between several converters Protection: Current/torque limit; overload, overcurrent, overvoltage, short circuits, undervoltage, overtemperature; earthing error; phase error input+output; Pre-alarms; Self-test The installation of the converter may only be carried out by professionals with basic electrical knowledge. Make sure the motor is designed for 230V3AC. Check the bridges in the engine terminal box. The converter has a basic interference suppression (according to EN61800-3). A frequency inverter is not in itself a system which can operate reasonably independently, but must always be regarded as a component of the entire drive system. Since we have no influence on the installation and wiring of the frequency inverter by the end customer, we cannot assume any guarantee for compliance with the EMV limit values of the overall drive system. However, the manufacturer has carried out the necessary certifications for common installations of frequency inverters and has established installation guidelines based on this. The frequency inverters comply with the applicable guidelines if the EG installation declaration is observed. This is documented by the CE character on the frequency inverter.
SKU:
6504
Shipping weight:
5.00 kg
Item weight:
5.00 kg
790,00 € *
Old price: 978,00 €
Available
Delivery time: 2 - 4 Workdays
Sale 57%

Performance: 400 kW (578 kVA)
Entrance: 380-480 V3AC ±10%, 50/60 Hz ±5%
Dimensions: BxHxT 880x1150x370 mm
Output rated current: 759 A
Output: 0-Uin [V3AC]; 0,01-500 (1000) Hz
Overload: 60 s 150%
Protection type: IP00
EMV interference suppression: to 75 kW: Class A integrated
Colour: RAL7016
Brake chopper: Only as an option
DC throttles: Module of attachment incl.

output frequency 0,01... 500 (1000) Hz; 380…480 V3AC ±10%; Overload for 60 s: 150%, 0,5s 215%; Easy Mode allows you to easily create your own operator guidance, driving dynamics learning function; SPS functions; Multi-PID controllers; lifting gear macro; sequence control, time-dependent or clamp-controlled; control of an ext. brake; seven different voltage-frequency characteristic curves can be adjusted, including vector calibration also with feedback; Brake chopper integrated up to 160 kW; positive/negative logic reversible; Side-by-side installation possible without a space; DC choke 18,5...75 kW integrated, 90...500 kW supplied as an add-on module; emergency stop; Vibratory strength 5,9m/s2 (0,6g); storage temperature −25... 65°C; Working temperature -10°C... +60°C (above 50°C current reduction according to FIG. Manual; humidity up to 95% (no condensation); Inputs/outputs: seven digital inputs, three analog inputs (11 bit); one output relay, two analog outputs and two digital outputs; Protective functions: all terminals are potential-free; soft shale; current limit; excess current; overvoltage; short circuit power supply side; earth short side undervoltage; voltage interruption; PRTC; electronic motor protection; inlet current on the mains and motor side; Brake resistance monitoring; FU temperature monitoring; Clock frequency 2.0-16.5 kHz adjustable

Extended functionality:
Secure stop according to IEC / EN61508-1 SIL2 or EN945-1 Cat. 3; Guided down-time in the event of a power failure; Traverse function for textile machines; torque and tension control; Online automation to adapt to changing operating conditions; positioning capability; Teaching mode: Optimal performance in hoisting gears; Reaction times of the inputs: Approximately 2ms; Zero speed lock (zero speed lock)

Functions:
The FU converts three-phase current 400 V3AC −> into direct current and then converts −> into a regulatable three-phase current, output frequency (rotational speed) can be continuously adjusted via the optionally integrated internal or optionally ext. potentiometer, i.e., speeds up to max. 50000 1/min; Multi-PID controller function; torque adjustable via current limitation (optionally via potentiometer); maximum voltage 50-660 V can be set; emergency stop; three acceleration and braking times adjustable with different ramp shapes; can be controlled with 15 different fixed frequencies (BCD coding of the inputs); engine trapping function; motor pokies; frequency-proportional speed can be displayed; typing operation (JOG function); the nominal frequency over 0-10 VDC or 0(4)-20mA; nominal value/frequency allocation; frequency bands can be masked; switchable via input to 2. engine parameter set; Residual current measurement (switch-off); Potential-free E/A; Advanced automatic functions; Block transfer communication; maintenance warnings; built-in SPS functions (with timer elements, counters); inputs/outputs, arithmetic functions, etc.; Emergency operation (ignoring all error messages); sequence control for controlling an external brake; hosiery macro; The dynamic learning function; Easy mode parameter setting; Secure stop according to IEC/EN61508-1 SIL2 or EN945-1 Cat. 3; controlled down-running in the event of a power failure; torque and tension control; Online automation to adapt to changing operating conditions; Positioning capability

Option/Accessories:
External TOUCH-PANNEL for individual controls; Additional inputs and outputs; speed sensor input; PTC thermistor tripping circuit board; RS232; RS485; CAN-BUS; PROFIBUS; INTERBUS; Modbus RTU; Device-Net; Lonbus; EMV filter class B; ext. Brake resistance; ext. potentiometer; in the IP54-Gehäuse; Output filter (du/dt- o) SINUS filter; DC choke; remote control with display; DIN rail attachment (TOS-DIN rail) <1,5 kW; PC-Parametriesoftware

Protection:
overload, torque over current limit, overcurrent, overvoltage, undervoltage, voltage limit, overtemperature, thermal motor monitoring, earth fault; output short, phase error input+output; ground fault, pre-alarms, self-test, residual current measurement (switch-off); Maintenance warnings

The installation of the FU may only be carried out by professionals with basic electrical knowledge. Make sure the motor is designed for the FU voltage, i.e. check the nameplate and bridges in the engine terminal box. The FU has a suppression (filter class A (EN55011) or category C2 (EN61800-3)). A FU is not a system that can operate reasonably independently, but must always be regarded as a component of the entire drive system. Since we have no influence on the installation and wiring of the FU by the end customer, we cannot assume any guarantee for compliance with the EMV limit values of the overall drive system. However, the necessary certifications were made for common installations of FUs and, based on this, installation guidelines were created. The FUs comply with the applicable guidelines if the EG installation declaration is observed. This is documented by the CE character on the FU.

SKU:
5400
Shipping weight:
250.00 kg
Item weight:
225.00 kg
19.400,00 € *
Old price: 45.219,00 €
Available
Delivery time: 3 - 5 Workdays