ORIENTAL MOTOR
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 5
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 1.1 A
Three-Phase 200 VAC / 60 Hz / 1.1 A
Three-Phase 220 VAC / 60 Hz / 0.95 A
Three-Phase 230 VAC VAC / 60 Hz / 0.95 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1.49 N·m
Three-Phase 200 VAC / 60 Hz: 1.25 N·m
Three-Phase 220 VAC / 60 Hz: 1.23 N·m
Three-Phase 230 VAC VAC / 60 Hz: 1.18 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1.49 N·m / 1250 r/min
Three-Phase 200 VAC / 60 Hz: 1.25 N·m / 1500 r/min
Three-Phase 220 VAC / 60 Hz: 1.23 N·m / 1550 r/min
Three-Phase 230 VAC VAC / 60 Hz: 1.18 N·m / 1600 r/min - The Speed When Installing gearhead: Three-Phase 200 VAC / 50 Hz: 300 r/min
Three-Phase 200 VAC / 60 Hz: 360 r/min
Three-Phase 220 VAC / 60 Hz: 360 r/min
Three-Phase 230 VAC VAC / 60 Hz: 360 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 200 VAC / 50 Hz: 5.4 N·m
Three-Phase 200 VAC / 60 Hz: 4.6 N·m
Three-Phase 220 VAC / 60 Hz: 4.5 N·m
Three-Phase 230 VAC VAC / 60 Hz: 4.3 N·m - Electromagnetic Brake Brake Type: Power off activated type
- Electromagnetic Brake Voltage/ Frequency/ Current/ Input: single-Phase 200 VAC / 50 Hz / 0.09 A / 12 W
single-Phase 200 VAC / 60 Hz / 0.09 A / 12 W
single-Phase 220 VAC / 60 Hz / 0.09 A / 12 W
single-Phase 230 VAC VAC / 60 Hz / 0.09 A / 12 W - Electromagnetic Brake Static Friction Torque (Motor Shaft): 1.5 N·m
- Permissible Inertia J: 50×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 11.5 kg (With gearhead)
[Note]
• Torque motor has a sloping characteristic, so the torque at the time of starting is the maximum.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 60
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 1.1 A
Three-Phase 200 VAC / 60 Hz / 1.1 A
Three-Phase 220 VAC / 60 Hz / 0.95 A
Three-Phase 230 VAC VAC / 60 Hz / 0.95 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1.49 N·m
Three-Phase 200 VAC / 60 Hz: 1.25 N·m
Three-Phase 220 VAC / 60 Hz: 1.23 N·m
Three-Phase 230 VAC VAC / 60 Hz: 1.18 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1.49 N·m / 1250 r/min
Three-Phase 200 VAC / 60 Hz: 1.25 N·m / 1500 r/min
Three-Phase 220 VAC / 60 Hz: 1.23 N·m / 1550 r/min
Three-Phase 230 VAC VAC / 60 Hz: 1.18 N·m / 1600 r/min - The Speed When Installing gearhead: Three-Phase 200 VAC / 50 Hz: 25 r/min
Three-Phase 200 VAC / 60 Hz: 30 r/min
Three-Phase 220 VAC / 60 Hz: 30 r/min
Three-Phase 230 VAC VAC / 60 Hz: 30 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 200 VAC / 50 Hz: 40 N·m
Three-Phase 200 VAC / 60 Hz: 40 N·m
Three-Phase 220 VAC / 60 Hz: 40 N·m
Three-Phase 230 VAC VAC / 60 Hz: 40 N·m - Electromagnetic Brake Brake Type: Power off activated type
- Electromagnetic Brake Voltage/ Frequency/ Current/ Input: single-Phase 200 VAC / 50 Hz / 0.09 A / 12 W
single-Phase 200 VAC / 60 Hz / 0.09 A / 12 W
single-Phase 220 VAC / 60 Hz / 0.09 A / 12 W
single-Phase 230 VAC VAC / 60 Hz / 0.09 A / 12 W - Electromagnetic Brake Static Friction Torque (Motor Shaft): 1.5 N·m
- Permissible Inertia J: 5000×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 9.5 kg (With gearhead)
[Note]
• Torque motor has a sloping characteristic, so the torque at the time of starting is the maximum.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 7.5
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 1.1 A
Three-Phase 200 VAC / 60 Hz / 1.1 A
Three-Phase 220 VAC / 60 Hz / 0.95 A
Three-Phase 230 VAC VAC / 60 Hz / 0.95 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1.49 N·m
Three-Phase 200 VAC / 60 Hz: 1.25 N·m
Three-Phase 220 VAC / 60 Hz: 1.23 N·m
Three-Phase 230 VAC VAC / 60 Hz: 1.18 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1.49 N·m / 1250 r/min
Three-Phase 200 VAC / 60 Hz: 1.25 N·m / 1500 r/min
Three-Phase 220 VAC / 60 Hz: 1.23 N·m / 1550 r/min
Three-Phase 230 VAC VAC / 60 Hz: 1.18 N·m / 1600 r/min - The Speed When Installing gearhead: Three-Phase 200 VAC / 50 Hz: 200 r/min
Three-Phase 200 VAC / 60 Hz: 240 r/min
Three-Phase 220 VAC / 60 Hz: 240 r/min
Three-Phase 230 VAC VAC / 60 Hz: 240 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 200 VAC / 50 Hz: 10.1 N·m
Three-Phase 200 VAC / 60 Hz: 8.4 N·m
Three-Phase 220 VAC / 60 Hz: 8.3 N·m
Three-Phase 230 VAC VAC / 60 Hz: 8 N·m - Electromagnetic Brake Brake Type: Power off activated type
- Electromagnetic Brake Voltage/ Frequency/ Current/ Input: single-Phase 200 VAC / 50 Hz / 0.09 A / 12 W
single-Phase 200 VAC / 60 Hz / 0.09 A / 12 W
single-Phase 220 VAC / 60 Hz / 0.09 A / 12 W
single-Phase 230 VAC VAC / 60 Hz / 0.09 A / 12 W - Electromagnetic Brake Static Friction Torque (Motor Shaft): 1.5 N·m
- Permissible Inertia J: 112×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 9.5 kg (With gearhead)
[Note]
• Torque motor has a sloping characteristic, so the torque at the time of starting is the maximum.
- Frame Size: 104 mm
- Output Power: 200 W
- series: BH series
- Type: With Terminal Box
- Gear Ratio: 7.5
- Time Rating: Continuous
- Rotation Direction: opposite direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 1.1 A
Three-Phase 200 VAC / 60 Hz / 1.1 A
Three-Phase 220 VAC / 60 Hz / 0.95 A
Three-Phase 230 VAC VAC / 60 Hz / 0.95 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1.49 N·m
Three-Phase 200 VAC / 60 Hz: 1.25 N·m
Three-Phase 220 VAC / 60 Hz: 1.23 N·m
Three-Phase 230 VAC VAC / 60 Hz: 1.18 N·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1.49 N·m / 1250 r/min
Three-Phase 200 VAC / 60 Hz: 1.25 N·m / 1500 r/min
Three-Phase 220 VAC / 60 Hz: 1.23 N·m / 1550 r/min
Three-Phase 230 VAC VAC / 60 Hz: 1.18 N·m / 1600 r/min - The Speed When Installing gearhead: Three-Phase 200 VAC / 50 Hz: 200 r/min
Three-Phase 200 VAC / 60 Hz: 240 r/min
Three-Phase 220 VAC / 60 Hz: 240 r/min
Three-Phase 230 VAC VAC / 60 Hz: 240 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 200 VAC / 50 Hz: 8.2 N·m
Three-Phase 200 VAC / 60 Hz: 6.8 N·m
Three-Phase 220 VAC / 60 Hz: 6.7 N·m
Three-Phase 230 VAC VAC / 60 Hz: 6.5 N·m - Electromagnetic Brake Brake Type: Power off activated type
- Electromagnetic Brake Voltage/ Frequency/ Current/ Input: single-Phase 200 VAC / 50 Hz / 0.09 A / 12 W
single-Phase 200 VAC / 60 Hz / 0.09 A / 12 W
single-Phase 220 VAC / 60 Hz / 0.09 A / 12 W
single-Phase 230 VAC VAC / 60 Hz / 0.09 A / 12 W - Electromagnetic Brake Static Friction Torque (Motor Shaft): 1.5 N·m
- Permissible Inertia J: 112×10-4 kg·m2
- Overheat Protective Device Type: Thermal protector
- Mass: 11.5 kg (With gearhead)
[Note]
• Torque motor has a sloping characteristic, so the torque at the time of starting is the maximum.