Motor surcharges
Items 1 - 20 of 21
triple-cable conductors, correspond to DIN 44082. temperature-dependent resistor having a positive temperature coefficient
Surcharge for PTO - bimetallic (2 terminals) including installation
If you want a drilling on both sides, please book the item 2x.
For number 1 installation for side drive shaft, for number 2 for both sides
Surcharge for PT100 - winding (2 terminals)
Surcharge for terminal box laterally
Surcharge for fixed bearing drive side
Additional protective roof
Extra price special voltage 500V
Additional protection type
In regions in which the winding is exposed to increased climatic conditions, it is recommended to design the winding with special tropical insulation. This winding can work by a modification up to a relative humidity of 90%. Up to an absolute humidity of 30 g of water per m3. The winding shall be avoided from being bevelled.
Surcharge for UL/CSA (only IE3 engines)
External cooling IC416 to DIN EN 60034-6 for IEC electric motors
A fan generator should be used under the following conditions:
- Operation of a motor at the frequency inverter, at low speeds or at rated torque at standstill
- High torque demand at low speeds
- Mounting of a transmitter system (the self-ventilator is removed)
- Drives with high switching frequency
- Drives operated above the rated speed (high fan noise)
Operating voltage 115 V or 230 V The stationary heaters presented are intended for use in electric machines. They are usually placed directly around the heads of the stator winding, preventing corrosion and frost damage and thus providing safe protection against machine failures. The heating conductor (resistance wire) made of CuNi or NiCr alloy is wound spirally onto a glass fiber carrier. The individual wires thus produced are connected in series by means of crimp sleeves. switched. For protection against moisture, the crimp connections are insulated with shrink hose and the heating conductors are coated with a silicone sheath (type: oGS. The voltage supply is provided via permanently connected PTFE / FEP single strands. The heating line can optionally also be sheathed with a glass silk raw hose (type: mGS. This contributes to the vacuum impregnation of the motor for better bonding to the impregnating resin and guarantees the best possible heat transfer to the motor.
Surcharge for coating C2
Surcharge for coating C3
Surcharge for coating C4
Extra price HARTING connector up to size 132
Surcharge for SPM-VIBCODE per side
Surcharge for of current-insulated B-side rolling bearing for FU operation
Items 1 - 20 of 21