Line chokes
Line reactors are used to make the power draw of frequency inverters and other electrical loads more grid-friendly. They can reduce current peaks, minimize harmonics, and help protect electrical components against mains disturbances and switching effects. Especially in sensitive power networks or demanding applications, line reactors contribute to higher operational reliability and a longer service life of the connected equipment.
Items 1 - 16 of 16
- Standards: VDE 0570; DIN EN 61558-2-20
- Rated voltage: 3 x 400 V
- Short-circuit voltage uk: 4% at 50 Hz
- Structure: Standing
- Corrosion and moisture protection: Complete vacuum impregnation
- Maximum ambient temperature: 40 °C
- Insulation class: BB
- Degree of protection: IP00 (installation up to IP23)
- Connections: Current-dependent, clamps or copper plates
- Electricity: 100 A
- Dimensions: a=240 mm; b = 141 mm; b1=155 mm; c=210 mm; d=190 mm; e=116 mm; f = 11,0 mm
- BxTxH: 240 x 141 x 155 mm
- Weight: 18,0 kg
- Standards: VDE 0570; DIN EN 61558-2-20
- Rated voltage: 3 x 400 V
- Short-circuit voltage uk: 4% at 50 Hz
- Structure: Standing
- Corrosion and moisture protection: Complete vacuum impregnation
- Maximum ambient temperature: 40 °C
- Insulation class: BB
- Degree of protection: IP00 (installation up to IP23)
- Connections: Current-dependent, clamps or copper plates
- Electricity: 1000 A
- Dimensions: a=420 mm; b = 253 mm; b1=275 mm; c=365 mm; d=370 mm; e=212 mm; f = 11,0 mm
- BxTxH: 420 x 253 x 275 mm
- Weight: 125,0 kg
- Standards: VDE 0570; DIN EN 61558-2-20
- Rated voltage: 3 x 400 V
- Short-circuit voltage uk: 4% at 50 Hz
- Structure: Standing
- Corrosion and moisture protection: Complete vacuum impregnation
- Maximum ambient temperature: 40 °C
- Insulation class: BB
- Degree of protection: IP00 (installation up to IP23)
- Connections: Current-dependent, clamps or copper plates
- Electricity: 125 A
- Dimensions: a=240 mm; b = 155 mm; b1=170 mm; c=210 mm; d=190 mm; e=130 mm; f = 11,0 mm
- BxTxH: 240 x 155 x 170 mm
- Weight: 22,0 kg
- Standards: VDE 0570; DIN EN 61558-2-20
- Rated voltage: 3 x 400 V
- Short-circuit voltage uk: 4% at 50 Hz
- Structure: Standing
- Corrosion and moisture protection: Complete vacuum impregnation
- Maximum ambient temperature: 40 °C
- Insulation class: BB
- Degree of protection: IP00 (installation up to IP23)
- Connections: Current-dependent, clamps or copper plates
- Electricity: 160 A
- Dimensions: a=300 mm; b = 152 mm; b1=177 mm; c=270 mm; d=240 mm; e=121 mm; f = 11,0 mm
- BxTxH: 300 x 152 x 177 mm
- Weight: 27,0 kg
- Standards: VDE 0570; DIN EN 61558-2-20
- Rated voltage: 3 x 400 V
- Short-circuit voltage uk: 4% at 50 Hz
- Structure: Standing
- Corrosion and moisture protection: Complete vacuum impregnation
- Maximum ambient temperature: 40 °C
- Insulation class: BB
- Degree of protection: IP00 (installation up to IP23)
- Connections: Current-dependent, clamps or copper plates
- Electricity: 200 A
- Dimensions: a=300 mm; b = 177 mm; b1=197 mm; c=270 mm; d=240 mm; e=146 mm; f = 11,0 mm
- BxTxH: 300 x 177 x 197 mm
- Weight: 36,0 kg
- Standards: VDE 0570; DIN EN 61558-2-20
- Rated voltage: 3 x 400 V
- Short-circuit voltage uk: 4% at 50 Hz
- Structure: Standing
- Corrosion and moisture protection: Complete vacuum impregnation
- Maximum ambient temperature: 40 °C
- Insulation class: BB
- Degree of protection: IP00 (installation up to IP23)
- Connections: Current-dependent, clamps or copper plates
- Electricity: 25 A
- Dimensions: a=190 mm; b = 81 mm; b1=91 mm; c=160 mm; d=170 mm; e=64 mm; f = 8,0 mm
- BxTxH: 190 x 81 x 91 mm
- Weight: 6,0 kg
- Standards: VDE 0570; DIN EN 61558-2-20
- Rated voltage: 3 x 400 V
- Short-circuit voltage uk: 4% at 50 Hz
- Structure: Standing
- Corrosion and moisture protection: Complete vacuum impregnation
- Maximum ambient temperature: 40 °C
- Insulation class: BB
- Degree of protection: IP00 (installation up to IP23)
- Connections: Current-dependent, clamps or copper plates
- Electricity: 250 A
- Dimensions: a=300 mm; b = 192 mm; b1=215 mm; c=270 mm; d=240 mm; e=161 mm; f = 11,0 mm
- BxTxH: 300 x 192 x 215 mm
- Weight: 44,0 kg
- Standards: VDE 0570; DIN EN 61558-2-20
- Rated voltage: 3 x 400 V
- Short-circuit voltage uk: 4% at 50 Hz
- Structure: Standing
- Corrosion and moisture protection: Complete vacuum impregnation
- Maximum ambient temperature: 40 °C
- Insulation class: BB
- Degree of protection: IP00 (installation up to IP23)
- Connections: Current-dependent, clamps or copper plates
- Electricity: 300 A
- Dimensions: a=360 mm; b = 163 mm; b1=185 mm; c=312 mm; d=310 mm; e=126 mm; f = 11,0 mm
- BxTxH: 360 x 163 x 185 mm
- Weight: 55,0 kg
- Standards: VDE 0570; DIN EN 61558-2-20
- Rated voltage: 3 x 400 V
- Short-circuit voltage uk: 4% at 50 Hz
- Structure: Standing
- Corrosion and moisture protection: Complete vacuum impregnation
- Maximum ambient temperature: 40 °C
- Insulation class: BB
- Degree of protection: IP00 (installation up to IP23)
- Connections: Current-dependent, clamps or copper plates
- Electricity: 350 A
- Dimensions: a=360 mm; b = 178 mm; b1=205 mm; c=312 mm; d=310 mm; e=141 mm; f = 11,0 mm
- BxTxH: 360 x 178 x 205 mm
- Weight: 58,0 kg
- Standards: VDE 0570; DIN EN 61558-2-20
- Rated voltage: 3 x 400 V
- Short-circuit voltage uk: 4% at 50 Hz
- Structure: Standing
- Corrosion and moisture protection: Complete vacuum impregnation
- Maximum ambient temperature: 40 °C
- Insulation class: BB
- Degree of protection: IP00 (installation up to IP23)
- Connections: Current-dependent, clamps or copper plates
- Electricity: 400 A
- Dimensions: a=360 mm; b = 178 mm; b1=205 mm; c=312 mm; d=310 mm; e=141 mm; f = 11,0 mm
- BxTxH: 360 x 178 x 205 mm
- Weight: 60,0 kg
- Standards: VDE 0570; DIN EN 61558-2-20
- Rated voltage: 3 x 400 V
- Short-circuit voltage uk: 4% at 50 Hz
- Structure: Standing
- Corrosion and moisture protection: Complete vacuum impregnation
- Maximum ambient temperature: 40 °C
- Insulation class: BB
- Degree of protection: IP00 (installation up to IP23)
- Connections: Current-dependent, clamps or copper plates
- Electricity: 50 A
- Dimensions: a=190 mm; b = 105 mm; b1=115 mm; c=160 mm; d=170 mm; e=80 mm; f = 8,0 mm
- BxTxH: 190 x 105 x 115 mm
- Weight: 9,5 kg
- Standards: VDE 0570; DIN EN 61558-2-20
- Rated voltage: 3 x 400 V
- Short-circuit voltage uk: 4% at 50 Hz
- Structure: Standing
- Corrosion and moisture protection: Complete vacuum impregnation
- Maximum ambient temperature: 40 °C
- Insulation class: BB
- Degree of protection: IP00 (installation up to IP23)
- Connections: Current-dependent, clamps or copper plates
- Electricity: 500 A
- Dimensions: a=360 mm; b = 193 mm; b1=220 mm; c=312 mm; d=310 mm; e=156 mm; f = 11,0 mm
- BxTxH: 360 x 193 x 220 mm
- Weight: 70,0 kg
according to VDE 0570 DIN EN 61558-2-20 Corrosion and moisture protection by complete vacuum impregnation, maximum Ambient temperature 40°C, insulation class B, protection class IP 00, suitable for installation up to IP 23 ED%: 100 Uprim: 3 x 400 Iprim: 63 A USek 1 0,465 mH UK 4 Iso.-Kl T40B Hz: 50 IP: 00 VDE: 0570 Dimensions BxTxH 240 x 121 x 135 Copper input weight 5,5 kg
- Standards: VDE 0570; DIN EN 61558-2-20
- Rated voltage: 3 x 400 V
- Short-circuit voltage uk: 4% at 50 Hz
- Structure: Standing
- Corrosion and moisture protection: Complete vacuum impregnation
- Maximum ambient temperature: 40 °C
- Insulation class: BB
- Degree of protection: IP00 (installation up to IP23)
- Connections: Current-dependent, clamps or copper plates
- Electricity: 650 A
- Dimensions: a=420 mm; b = 212 mm; b1=240 mm; c=365 mm; d=370 mm; e=167 mm; f = 11,0 mm
- BxTxH: 420 x 212 x 240 mm
- Weight: 88,0 kg
- Standards: VDE 0570; DIN EN 61558-2-20
- Rated voltage: 3 x 400 V
- Short-circuit voltage uk: 4% at 50 Hz
- Structure: Standing
- Corrosion and moisture protection: Complete vacuum impregnation
- Maximum ambient temperature: 40 °C
- Insulation class: BB
- Degree of protection: IP00 (installation up to IP23)
- Connections: Current-dependent, clamps or copper plates
- Electricity: 80 A
- Dimensions: a=240 mm; b = 131 mm; b1=145 mm; c=210 mm; d=190 mm; e=106 mm; f = 11,0 mm
- BxTxH: 240 x 131 x 145 mm
- Weight: 16,0 kg
- Standards: VDE 0570; DIN EN 61558-2-20
- Rated voltage: 3 x 400 V
- Short-circuit voltage uk: 4% at 50 Hz
- Structure: Standing
- Corrosion and moisture protection: Complete vacuum impregnation
- Maximum ambient temperature: 40 °C
- Insulation class: BB
- Degree of protection: IP00 (installation up to IP23)
- Connections: Current-dependent, clamps or copper plates
- Electricity: 800 A
- Dimensions: a=420 mm; b = 223 mm; b1=245 mm; c=365 mm; d=370 mm; e=182 mm; f = 11,0 mm
- BxTxH: 420 x 223 x 245 mm
- Weight: 105,0 kg
Items 1 - 16 of 16