KEMMERICH ELEKTROMOTOREN
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4340 min-1
- RATED FREQUENCY: 72,7 Hz
- OUTPUT POWER: 125 kW (S1) / 163 kW (S6-40%)
- RATED TORQUE: 275 Nm (S1) / 358 Nm (S6-40%)
- RATED CURRENT: 206 A (S1) / 269 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 9500 min-1 (S1) / 7600 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 125 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,31 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 5690 min-1
- RATED FREQUENCY: 95,3 Hz
- OUTPUT POWER: 139 kW (S1) / 181 kW (S6-40%)
- RATED TORQUE: 234 Nm (S1) / 304 Nm (S6-40%)
- RATED CURRENT: 223 A (S1) / 294 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 9400 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 170 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,31 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4280 min-1
- RATED FREQUENCY: 71,7 Hz
- OUTPUT POWER: 123 kW (S1) / 160 kW (S6-40%)
- RATED TORQUE: 275 Nm (S1) / 358 Nm (S6-40%)
- RATED CURRENT: 177 A (S1) / 230 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 9350 min-1 (S1) / 7500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 120 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,31 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 5890 min-1
- RATED FREQUENCY: 98,6 Hz
- OUTPUT POWER: 144 kW (S1) / 187 kW (S6-40%)
- RATED TORQUE: 234 Nm (S1) / 304 Nm (S6-40%)
- RATED CURRENT: 200 A (S1) / 264 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 9750 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 185 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,31 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4320 min-1
- RATED FREQUENCY: 72,4 Hz
- OUTPUT POWER: 144 kW (S1) / 187 kW (S6-40%)
- RATED TORQUE: 318 Nm (S1) / 414 Nm (S6-40%)
- RATED CURRENT: 228 A (S1) / 305 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 9600 min-1 (S1) / 7800 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 145 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,36 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 5490 min-1
- RATED FREQUENCY: 91,9 Hz
- OUTPUT POWER: 154 kW (S1) / 200 kW (S6-40%)
- RATED TORQUE: 267 Nm (S1) / 347 Nm (S6-40%)
- RATED CURRENT: 245 A (S1) / 321 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 9500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 190 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,36 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4470 min-1
- RATED FREQUENCY: 74,9 Hz
- OUTPUT POWER: 149 kW (S1) / 194 kW (S6-40%)
- RATED TORQUE: 318 Nm (S1) / 414 Nm (S6-40%)
- RATED CURRENT: 205 A (S1) / 275 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 9950 min-1 (S1) / 8050 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 155 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,36 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 5610 min-1
- RATED FREQUENCY: 93,9 Hz
- OUTPUT POWER: 157 kW (S1) / 204 kW (S6-40%)
- RATED TORQUE: 267 Nm (S1) / 347 Nm (S6-40%)
- RATED CURRENT: 218 A (S1) / 285 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 9700 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 200 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,36 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4090 min-1
- RATED FREQUENCY: 68,6 Hz
- OUTPUT POWER: 159 kW (S1) / 206 kW (S6-40%)
- RATED TORQUE: 370 Nm (S1) / 481 Nm (S6-40%)
- RATED CURRENT: 259 A (S1) / 336 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 8000 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 165 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,42 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 5330 min-1
- RATED FREQUENCY: 89,1 Hz
- OUTPUT POWER: 173 kW (S1) / 225 kW (S6-40%)
- RATED TORQUE: 310 Nm (S1) / 403 Nm (S6-40%)
- RATED CURRENT: 274 A (S1) / 359 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 9800 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 220 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,42 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4180 min-1
- RATED FREQUENCY: 70,1 Hz
- OUTPUT POWER: 162 kW (S1) / 211 kW (S6-40%)
- RATED TORQUE: 370 Nm (S1) / 481 Nm (S6-40%)
- RATED CURRENT: 230 A (S1) / 299 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 8200 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 175 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,42 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 5360 min-1
- RATED FREQUENCY: 89,7 Hz
- OUTPUT POWER: 174 kW (S1) / 226 kW (S6-40%)
- RATED TORQUE: 310 Nm (S1) / 403 Nm (S6-40%)
- RATED CURRENT: 239 A (S1) / 314 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 9850 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 225 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,42 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3940 min-1
- RATED FREQUENCY: 66,0 Hz
- OUTPUT POWER: 182 kW (S1) / 237 kW (S6-40%)
- RATED TORQUE: 442 Nm (S1) / 575 Nm (S6-40%)
- RATED CURRENT: 295 A (S1) / 369 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 8800 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 210 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,48 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 5120 min-1
- RATED FREQUENCY: 85,6 Hz
- OUTPUT POWER: 200 kW (S1) / 260 kW (S6-40%)
- RATED TORQUE: 372 Nm (S1) / 484 Nm (S6-40%)
- RATED CURRENT: 316 A (S1) / 418 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 9700 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 250 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,48 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3960 min-1
- RATED FREQUENCY: 66,4 Hz
- OUTPUT POWER: 183 kW (S1) / 238 kW (S6-40%)
- RATED TORQUE: 442 Nm (S1) / 575 Nm (S6-40%)
- RATED CURRENT: 258 A (S1) / 323 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 8850 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 210 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,48 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 5040 min-1
- RATED FREQUENCY: 84,4 Hz
- OUTPUT POWER: 197 kW (S1) / 256 kW (S6-40%)
- RATED TORQUE: 372 Nm (S1) / 484 Nm (S6-40%)
- RATED CURRENT: 271 A (S1) / 358 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 9550 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 245 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,48 kgm2