Immersion pumps
Immersion pumps (standard coolant pump) are self-venting and usually have an exposed shaft. This eliminates the need for a bearing in the pump section. The pumps are safe to run dry, wear-resistant and operate with large clearances, making them insensitive to swarf.
- Simple installation directly on the container
- Simple pipework due to SAE/replaceable flange
- Long service life, partly sealless or with low-wear plain bearings
- Multi-stage design (steep characteristic curves) possible
- Immersion depth of up to 1.5 m possible
- all wetted parts are partly available in stainless steel
• flow rate: 75 l/min at delivery head 2 m
• immersion depth: 105 mm
• pipe connection: G 3/4
• power: 0.21 kW
• speed 50 Hz / 60 Hz: 2800 / 3300 min?1
• semi-open impeller
• voltage 220-240/380-415 V/50 Hz or 460 V/60 Hz
application
• pumped media coolant emulsions
• cooling and cutting oils
• kinematic viscosity ...45 mm²/s (45 cSt)
• fluid temperature 0...60° C
• higher temperatures on request
construction
• pump body grey cast iron
• cover Polyoxymethylen (POM)
• impeller Polyoxymethylen (POM)
• shaft steel
Auf Wunsch
• cover grey cast iron (TA160...TA400)
• suction cover with connection thread
• impeller brass (TA160...TA400)
• cast steel
• flow rate: 75 l/min at delivery head 2 m
• immersion depth: 120 mm
• pipe connection: G 3/4
• power: 0.21 kW
• speed 50 Hz / 60 Hz: 2800 / 3300 min?1
• semi-open impeller
• voltage 220-240/380-415 V/50 Hz or 460 V/60 Hz
application
• pumped media coolant emulsions
• cooling and cutting oils
• kinematic viscosity ...45 mm²/s (45 cSt)
• fluid temperature 0...60° C
• higher temperatures on request
construction
• pump body grey cast iron
• cover Polyoxymethylen (POM)
• impeller Polyoxymethylen (POM)
• shaft steel
Auf Wunsch
• cover grey cast iron (TA160...TA400)
• suction cover with connection thread
• impeller brass (TA160...TA400)
• cast steel
• flow rate: 75 l/min at delivery head 2 m
• immersion depth: 170 mm
• pipe connection: G 3/4
• power: 0.21 kW
• speed 50 Hz / 60 Hz: 2800 / 3300 min?1
• semi-open impeller
• voltage 220-240/380-415 V/50 Hz or 460 V/60 Hz
application
• pumped media coolant emulsions
• cooling and cutting oils
• kinematic viscosity ...45 mm²/s (45 cSt)
• fluid temperature 0...60° C
• higher temperatures on request
construction
• pump body grey cast iron
• cover Polyoxymethylen (POM)
• impeller Polyoxymethylen (POM)
• shaft steel
Auf Wunsch
• cover grey cast iron (TA160...TA400)
• suction cover with connection thread
• impeller brass (TA160...TA400)
• cast steel
• flow rate: 75 l/min at delivery head 2 m
• immersion depth: 220 mm
• pipe connection: G 3/4
• power: 0.21 kW
• speed 50 Hz / 60 Hz: 2800 / 3300 min?1
• semi-open impeller
• voltage 220-240/380-415 V/50 Hz or 460 V/60 Hz
application
• pumped media coolant emulsions
• cooling and cutting oils
• kinematic viscosity ...45 mm²/s (45 cSt)
• fluid temperature 0...60° C
• higher temperatures on request
construction
• pump body grey cast iron
• cover Polyoxymethylen (POM)
• impeller Polyoxymethylen (POM)
• shaft steel
Auf Wunsch
• cover grey cast iron (TA160...TA400)
• suction cover with connection thread
• impeller brass (TA160...TA400)
• cast steel
• flow rate: 75 l/min at delivery head 2 m
• immersion depth: 270 mm
• pipe connection: G 3/4
• power: 0.21 kW
• speed 50 Hz / 60 Hz: 2800 / 3300 min?1
• semi-open impeller
• voltage 220-240/380-415 V/50 Hz or 460 V/60 Hz
application
• pumped media coolant emulsions
• cooling and cutting oils
• kinematic viscosity ...45 mm²/s (45 cSt)
• fluid temperature 0...60° C
• higher temperatures on request
construction
• pump body grey cast iron
• cover Polyoxymethylen (POM)
• impeller Polyoxymethylen (POM)
• shaft steel
Auf Wunsch
• cover grey cast iron (TA160...TA400)
• suction cover with connection thread
• impeller brass (TA160...TA400)
• cast steel
• flow rate: 75 l/min at delivery head 2 m
• immersion depth: 350 mm
• pipe connection: G 3/4
• power: 0.21 kW
• speed 50 Hz / 60 Hz: 2800 / 3300 min?1
• semi-open impeller
• voltage 220-240/380-415 V/50 Hz or 460 V/60 Hz
application
• pumped media coolant emulsions
• cooling and cutting oils
• kinematic viscosity ...45 mm²/s (45 cSt)
• fluid temperature 0...60° C
• higher temperatures on request
construction
• pump body grey cast iron
• cover Polyoxymethylen (POM)
• impeller Polyoxymethylen (POM)
• shaft steel
Auf Wunsch
• cover grey cast iron (TA160...TA400)
• suction cover with connection thread
• impeller brass (TA160...TA400)
• cast steel