IP23 high-speed motors KHH
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3450 min-1
- RATED FREQUENCY: 57,7 Hz
- OUTPUT POWER: 257 kW (S1) / 334 kW (S6-40%)
- RATED TORQUE: 710 Nm (S1) / 925 Nm (S6-40%)
- RATED CURRENT: 427 A (S1) / 547 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 9000 min-1 (S1) / 6800 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 225 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,1 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4700 min-1
- RATED FREQUENCY: 78,6 Hz
- OUTPUT POWER: 289 kW (S1) / 375 kW (S6-40%)
- RATED TORQUE: 585 Nm (S1) / 765 Nm (S6-40%)
- RATED CURRENT: 462 A (S1) / 598 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 8800 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 330 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,1 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3310 min-1
- RATED FREQUENCY: 55,3 Hz
- OUTPUT POWER: 246 kW (S1) / 320 kW (S6-40%)
- RATED TORQUE: 710 Nm (S1) / 925 Nm (S6-40%)
- RATED CURRENT: 356 A (S1) / 456 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 8650 min-1 (S1) / 6500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 210 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,1 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4320 min-1
- RATED FREQUENCY: 72,3 Hz
- OUTPUT POWER: 265 kW (S1) / 345 kW (S6-40%)
- RATED TORQUE: 585 Nm (S1) / 765 Nm (S6-40%)
- RATED CURRENT: 370 A (S1) / 479 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 8100 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 280 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,1 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 375 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4650 min-1
- RATED FREQUENCY: 77,7 Hz
- OUTPUT POWER: 361 kW (S1) / 469 kW (S6-40%)
- RATED TORQUE: 740 Nm (S1) / 965 Nm (S6-40%)
- RATED CURRENT: 616 A (S1) / 796 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 9800 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 460 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,4 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3470 min-1
- RATED FREQUENCY: 58,0 Hz
- OUTPUT POWER: 320 kW (S1) / 417 kW (S6-40%)
- RATED TORQUE: 880 Nm (S1) / 1145 Nm (S6-40%)
- RATED CURRENT: 525 A (S1) / 676 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 9700 min-1 (S1) / 7500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 310 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,4 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3190 min-1
- RATED FREQUENCY: 53,4 Hz
- OUTPUT POWER: 295 kW (S1) / 383 kW (S6-40%)
- RATED TORQUE: 880 Nm (S1) / 1145 Nm (S6-40%)
- RATED CURRENT: 420 A (S1) / 541 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 8900 min-1 (S1) / 6900 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 265 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,4 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4280 min-1
- RATED FREQUENCY: 71,5 Hz
- OUTPUT POWER: 332 kW (S1) / 432 kW (S6-40%)
- RATED TORQUE: 740 Nm (S1) / 965 Nm (S6-40%)
- RATED CURRENT: 462 A (S1) / 597 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 9000 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 390 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,4 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 310 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4550 min-1
- RATED FREQUENCY: 76,0 Hz
- OUTPUT POWER: 449 kW (S1) / 583 kW (S6-40%)
- RATED TORQUE: 940 Nm (S1) / 1225 Nm (S6-40%)
- RATED CURRENT: 915 A (S1) / 1188 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 10000 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 583 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,7 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3620 min-1
- RATED FREQUENCY: 60,6 Hz
- OUTPUT POWER: 414 kW (S1) / 538 kW (S6-40%)
- RATED TORQUE: 1090 Nm (S1) / 1420 Nm (S6-40%)
- RATED CURRENT: 685 A (S1) / 872 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 8500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 455 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,7 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3120 min-1
- RATED FREQUENCY: 52,3 Hz
- OUTPUT POWER: 357 kW (S1) / 464 kW (S6-40%)
- RATED TORQUE: 1090 Nm (S1) / 1420 Nm (S6-40%)
- RATED CURRENT: 514 A (S1) / 654 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 9900 min-1 (S1) / 7350 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 340 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,7 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4500 min-1
- RATED FREQUENCY: 75,1 Hz
- OUTPUT POWER: 444 kW (S1) / 577 kW (S6-40%)
- RATED TORQUE: 940 Nm (S1) / 1225 Nm (S6-40%)
- RATED CURRENT: 610 A (S1) / 792 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 10000 min-1 (S1) / 10000 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 577 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 10000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 8000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 1,7 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2990 min-1
- RATED FREQUENCY: 50,1 Hz
- OUTPUT POWER: 360 kW (S1) / 470 kW (S6-40%)
- RATED TORQUE: 1150 Nm (S1) / 1500 Nm (S6-40%)
- RATED CURRENT: 590 A (S1) / 770 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 7200 min-1 (S1) / 5400 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 280 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 7000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 2,28 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4010 min-1
- RATED FREQUENCY: 67,1 Hz
- OUTPUT POWER: 420 kW (S1) / 546 kW (S6-40%)
- RATED TORQUE: 1000 Nm (S1) / 1300 Nm (S6-40%)
- RATED CURRENT: 675 A (S1) / 880 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 8700 min-1 (S1) / 7000 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 425 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 7000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 2,28 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2860 min-1
- RATED FREQUENCY: 47,9 Hz
- OUTPUT POWER: 345 kW (S1) / 450 kW (S6-40%)
- RATED TORQUE: 1150 Nm (S1) / 1500 Nm (S6-40%)
- RATED CURRENT: 495 A (S1) / 640 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 6900 min-1 (S1) / 5150 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 260 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 7000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 2,28 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4720 min-1
- RATED FREQUENCY: 78,9 Hz
- OUTPUT POWER: 470 kW (S1) / 610 kW (S6-40%)
- RATED TORQUE: 950 Nm (S1) / 1235 Nm (S6-40%)
- RATED CURRENT: 655 A (S1) / 860 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 9000 min-1 (S1) / 8500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 575 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 7000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 2,28 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2900 min-1
- RATED FREQUENCY: 48,5 Hz
- OUTPUT POWER: 455 kW (S1) / 592 kW (S6-40%)
- RATED TORQUE: 1500 Nm (S1) / 1950 Nm (S6-40%)
- RATED CURRENT: 735 A (S1) / 955 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 7400 min-1 (S1) / 5600 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 370 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 7000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 2,95 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4040 min-1
- RATED FREQUENCY: 67,5 Hz
- OUTPUT POWER: 550 kW (S1) / 715 kW (S6-40%)
- RATED TORQUE: 1300 Nm (S1) / 1690 Nm (S6-40%)
- RATED CURRENT: 880 A (S1) / 1135 A (S6-40%)
- EFFICIENCY: 96,5 %
- CONSTANT-POWER RANGE max.: 9000 min-1 (S1) / 7200 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 570 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 7000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 2,95 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2640 min-1
- RATED FREQUENCY: 44,2 Hz
- OUTPUT POWER: 426 kW (S1) / 560 kW (S6-40%)
- RATED TORQUE: 1540 Nm (S1) / 2025 Nm (S6-40%)
- RATED CURRENT: 600 A (S1) / 785 A (S6-40%)
- EFFICIENCY: 96,0 %
- CONSTANT-POWER RANGE max.: 6750 min-1 (S1) / 5100 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 315 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 7000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 2,95 kgm2
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / HS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4040 min-1
- RATED FREQUENCY: 67,5 Hz
- OUTPUT POWER: 550 kW (S1) / 715 kW (S6-40%)
- RATED TORQUE: 1300 Nm (S1) / 1690 Nm (S6-40%)
- RATED CURRENT: 763 A (S1) / 1703 A (S6-40%)
- EFFICIENCY: 96,5 %
- CONSTANT-POWER RANGE max.: 9000 min-1 (S1) / 7200 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 570 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 9000 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 7000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 2,95 kgm2