3AC pole-changing motors
Standard three-phase motors
Pole-changing three-phase motor - Constant torque
| Motor frame size | 132M |
|---|---|
| Number of poles | 8/4 |
| Output power | 3/4.5 kW |
| Synchronous speed at 50 Hz | 750/1500 min-1 |
| Application | Constant torque |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Δ/YY - Dahlander |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.
Pole-changing three-phase motor
| Number of poles | 4 | 2 |
|---|---|---|
| Rated output [kW] | 1.3 | 5.2 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | YY |
| Rated speed [min-1] | 1470 | 2910 |
| Rated current [A] | 2.8 | 11.2 |
| Rated torque [N·m] | 8.4 | 17.1 |
| Efficiency at rated load [%] | 83.8 | 77 |
| Power factor cos φ | 0.82 | 0.87 |
| Starting current / rated current | 7 | 6.7 |
| Starting torque / rated torque | 1.8 | 2.2 |
| Breakdown torque / rated torque | 3 | 2.9 |
Frame size: 132S · IP55 · F · IM B3 · 57 kg
Pole-changing three-phase motor - Fan drive
| Motor frame size | 132S |
|---|---|
| Number of poles | 4/2 |
| Output power | 1.5/5.5 kW |
| Synchronous speed at 50 Hz | 1500/3000 min-1 |
| Application | Fan drive |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Y/YY - Dahlander |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.
Pole-changing three-phase motor - Constant torque
| Motor frame size | 132S |
|---|---|
| Number of poles | 4/2 |
| Output power | 5/6 kW |
| Synchronous speed at 50 Hz | 1500/3000 min-1 |
| Application | Constant torque |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Δ/YY - Dahlander |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.
Pole-changing three-phase motor
| Number of poles | 6 | 4 |
|---|---|---|
| Rated output [kW] | 1.2 | 3.4 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | Y |
| Rated speed [min-1] | 940 | 1450 |
| Rated current [A] | 2.9 | 7 |
| Rated torque [N·m] | 12.2 | 22.4 |
| Efficiency at rated load [%] | 69.3 | 80 |
| Power factor cos φ | 0.86 | 0.87 |
| Starting current / rated current | 3.8 | 5.8 |
| Starting torque / rated torque | 1.2 | 1.6 |
| Breakdown torque / rated torque | 2 | 2.3 |
Frame size: 132S · IP55 · F · IM B3 · 56 kg
Pole-changing three-phase motor - Fan drive
| Motor frame size | 132S |
|---|---|
| Number of poles | 6/4 |
| Output power | 1.3/4 kW |
| Synchronous speed at 50 Hz | 1000/1500 min-1 |
| Application | Fan drive |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Y/Y - Separate windings |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.
Pole-changing three-phase motor
| Number of poles | 6 | 4 |
|---|---|---|
| Rated output [kW] | 2.5 | 3.5 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | Y |
| Rated speed [min-1] | 970 | 1440 |
| Rated current [A] | 6.4 | 7 |
| Rated torque [N·m] | 24.6 | 23.2 |
| Efficiency at rated load [%] | 77 | 81 |
| Power factor cos φ | 0.74 | 0.89 |
| Starting current / rated current | 5.3 | 5.5 |
| Starting torque / rated torque | 1.8 | 1.6 |
| Breakdown torque / rated torque | 2.6 | 2 |
Frame size: 132S · IP55 · F · IM B3 · 60 kg
Pole-changing three-phase motor - Constant torque
| Motor frame size | 132S |
|---|---|
| Number of poles | 6/4 |
| Output power | 2/3.1 kW |
| Synchronous speed at 50 Hz | 1000/1500 min-1 |
| Application | Constant torque |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Y/Y - Separate windings |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.
Pole-changing three-phase motor - Fan drive
| Motor frame size | 132S |
|---|---|
| Number of poles | 8/4 |
| Output power | 1.1/5.5 kW |
| Synchronous speed at 50 Hz | 750/1500 min-1 |
| Application | Fan drive |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Y/YY - Dahlander |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.
Pole-changing three-phase motor
| Number of poles | 8 | 4 |
|---|---|---|
| Rated output [kW] | 1 | 4 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | YY |
| Rated speed [min-1] | 700 | 1420 |
| Rated current [A] | 2.7 | 8 |
| Rated torque [N·m] | 13.6 | 26.9 |
| Efficiency at rated load [%] | 72.3 | 80.4 |
| Power factor cos φ | 0.75 | 0.9 |
| Starting current / rated current | 3.6 | 5.3 |
| Starting torque / rated torque | 1.3 | 1.6 |
| Breakdown torque / rated torque | 2 | 2 |
Frame size: 132S · IP55 · F · IM B3 · 56 kg
Pole-changing three-phase motor - Constant torque
| Motor frame size | 132S |
|---|---|
| Number of poles | 8/4 |
| Output power | 2.2/3.3 kW |
| Synchronous speed at 50 Hz | 750/1500 min-1 |
| Application | Constant torque |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Δ/YY - Dahlander |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.
Pole-changing three-phase motor - Constant torque
| Motor frame size | 160L |
|---|---|
| Number of poles | 4/2 |
| Output power | 12.5/15 kW |
| Synchronous speed at 50 Hz | 1500/3000 min-1 |
| Application | Constant torque |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Δ/YY - Dahlander |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.
Pole-changing three-phase motor
| Number of poles | 4 | 2 |
|---|---|---|
| Rated output [kW] | 13 | 16 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Δ | YY |
| Rated speed [min-1] | 1455 | 2915 |
| Rated current [A] | 25.1 | 29.1 |
| Rated torque [N·m] | 85.3 | 52.4 |
| Efficiency at rated load [%] | 88 | 86.4 |
| Power factor cos φ | 0.85 | 0.92 |
| Starting current / rated current | 6.8 | 7.6 |
| Starting torque / rated torque | 2 | 2 |
| Breakdown torque / rated torque | 2.6 | 2.7 |
Frame size: 160L · IP55 · F · IM B3 · 130 kg
Pole-changing three-phase motor - Fan drive
| Motor frame size | 160L |
|---|---|
| Number of poles | 4/2 |
| Output power | 4.3/17 kW |
| Synchronous speed at 50 Hz | 1500/3000 min-1 |
| Application | Fan drive |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Y/YY - Dahlander |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.
Pole-changing three-phase motor
| Number of poles | 4 | 2 |
|---|---|---|
| Rated output [kW] | 4 | 15 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | YY |
| Rated speed [min-1] | 1470 | 2930 |
| Rated current [A] | 7.9 | 27.7 |
| Rated torque [N·m] | 26 | 48.9 |
| Efficiency at rated load [%] | 87.3 | 86.6 |
| Power factor cos φ | 0.84 | 0.9 |
| Starting current / rated current | 6.9 | 8.3 |
| Starting torque / rated torque | 1.9 | 2.1 |
| Breakdown torque / rated torque | 3 | 3 |
Frame size: 160L · IP55 · F · IM B3 · 122 kg
Pole-changing three-phase motor
| Number of poles | 6 | 4 |
|---|---|---|
| Rated output [kW] | 3.3 | 10 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
Frame size: 160L · IP55 · F · IM B3 · 135 kg
Pole-changing three-phase motor - Fan drive
| Motor frame size | 160L |
|---|---|
| Number of poles | 6/4 |
| Output power | 5.5/15 kW |
| Synchronous speed at 50 Hz | 1000/1500 min-1 |
| Application | Fan drive |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Y/Y - Separate windings |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.
Pole-changing three-phase motor - Constant torque
| Motor frame size | 160L |
|---|---|
| Number of poles | 6/4 |
| Output power | 6.5/9.5 kW |
| Synchronous speed at 50 Hz | 1000/1500 min-1 |
| Application | Constant torque |
| Housing material | Aluminium |
| Voltage | 400 V 3AC |
| Frequency | 50 Hz |
| Winding / connection | Y/Y - Separate windings |
| Degree of protection | IP55 |
| Insulation class | F |
| Thermal protection | PTC 150 °C |
| Terminal box | Top |
| Mounting arrangement | B3 / B5 / B14 / B35 / B34 / V1 |
The stated speeds are synchronous speeds. Rated speeds under load, currents, weights and detailed dimensions are available on request.
Illustrative image; the design depends on the selected mounting arrangement.
Pole-changing three-phase motor
| Number of poles | 6 | 4 |
|---|---|---|
| Rated output [kW] | 7 | 10.8 |
| Voltage [V] | 400 | 400 |
| Frequency [Hz] | 50 | 50 |
| Winding connection | Y | Y |
| Rated speed [min-1] | 970 | 1450 |
| Rated current [A] | 15 | 20.4 |
| Rated torque [N·m] | 68.9 | 71.2 |
| Efficiency at rated load [%] | 85 | 86.8 |
| Power factor cos φ | 0.79 | 0.88 |
| Starting current / rated current | 7.3 | 7.2 |
| Starting torque / rated torque | 2.3 | 1.9 |
| Breakdown torque / rated torque | 2.9 | 2.8 |
Frame size: 160L · IP55 · F · IM B3 · 135 kg
Pole-changing three-phase motor
| Number of poles | 6 | 4 | 2 |
|---|---|---|---|
| Rated output [kW] | 5.5 | 8.3 | 10.9 |
| Voltage [V] | 400 | 400 | 400 |
| Frequency [Hz] | 50 | 50 | 50 |
| Winding connection | Y | Δ | YY |
| Rated speed [min-1] | 965 | 1465 | 2935 |
| Rated current [A] | 13.4 | 17.7 | 20.7 |
| Rated torque [N·m] | 54.4 | 54.1 | 35.5 |
| Efficiency at rated load [%] | 82.1 | 85.6 | 83.6 |
| Power factor cos φ | 0.72 | 0.79 | 0.91 |
| Starting current / rated current | 5.3 | 7.3 | 7.7 |
| Starting torque / rated torque | 2 | 2 | 1.8 |
| Breakdown torque / rated torque | 2.4 | 3.1 | 3.1 |
Frame size: 160L · IP55 · F · IM B3 · 130 kg