3AC pole-changing motors
Standard three-phase motors
17/27 kW; S1; 740/1470 min-1; 400V Δ/YY 50 Hz 3AC; 40,0/48,5 A; 219/175 Nm
attract current 6,0/6,9xIn; starting torque 2,7/1,8xMn; tilting moment 2,7/2,4xMn
Efficiency 85,2/87,6%
Power values Basic design (constant torque)
7,0/28 kW; S1; 735/1470 min-1; 400V Y/YY 50 Hz 3AC 14,8/54,0 A; 91/182 Nm
attract current 5,2/6,3xIn; starting torque 1,8/2,1xMn; tilting moment 2,3/2,6xMn
Efficiency 84,5/89,7%
Power values Fan design (square torque)
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø55 x 110 mm; heat class 155(F); incl. 3x PTC temperature sensors
Housing material up to frame size 112 aluminum, from frame size 132 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: NU312.C3; Camp BS: 6312.C3; Moment of inertia 0,47 kgm2
half-wedge weighting species; vibration stage "A"; Insulation class F
sound pressure level 60/69 dB; terminal box position on the right; Number of terminals 9
Paint RAL5010
16/23 kW; S1; 985/1473 min-1; 400V Δ/YY 50 Hz 3AC; 30/42 A; 155/149 Nm
attract current 6,4/6,4xIn; starting torque 1,5/1,5xMn; tilting moment 2,5/2,3xMn
Efficiency 86/87%
Power values Basic design (constant torque)
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø55 x 110 mm; heat class 155(F); incl. 3x PTC temperature sensors
housing material grey cast iron; With bearing post-lubricating device
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6312P63E1; Camp BS: 6312P63E1; Moment of inertia 0,47 kgm2
half-wedge weighting species; vibration stage "A"; Insulation class F
terminal box position on the right-left side possible; bearing lubrication yes; RAL5010Lackierung RAL5010; with 3 PTC resistor PTC - for disconnection (2 terminals)
14/19 kW; S1; 886/1184 min-1; 460V Δ/YY 50 Hz 3AC; 40,0/48,5 A; 155/155 Nm
attract current 6,2/7,1xIn; starting torque 2,3/2,1xMn; tilting moment 2,5/2,7xMn
Efficiency 84,0/86,5%
Power values Basic design (constant torque)
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø55 x 110 mm; heat class 155(F); incl. 3x PTC temperature sensors
housing material grey cast iron; With bearing post-lubricating device
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6312P63E1; Camp BS: 6312P63E1; Moment of inertia 0,45 kgm2
half-wedge weighting species; vibration stage "A"; Insulation class F
terminal box position on the right; Number of terminals 6
Paint RAL5010
1,60/2,40 kW; S1; 1405/2750 1/min;
400V ∆/YY 50 Hz 3AC; 3,7/4,8 A; 10,9/8,24 Nm
Power values correspond to basic design (constant torque)
attracting current 5,0/4,8 x In; starting torque 1,9/1,4 x Mn; tilting moment 2,1/2,0 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø24 x 50 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6205.ZZ.C3; Camp BS: 6205.ZZ.C3; moment of inertia 0,0148 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010
0,70/1,10 kW; S1; 935/1410 1/min; 400V ∆/YY 50 Hz 3AC; 2,2/2,9 A; 7,15/7,45 Nm
Power values correspond to basic design (constant torque)
attracting current 2,2/2,9 x In; starting torque 1,6/1,4 x Mn; tilting moment 3,6/4,2 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø24 x 50 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6205.ZZ.C3; Camp BS: 6205.ZZ.C3; moment of inertia 0,0032 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010; Efficiency 63,7%/67,7%
0,55/1,00 kW; S1; 695/1380 1/min; 400V ∆/YY 50 Hz 3AC; 2,1/2,2 A; 7,56/6,92 Nm
attracting current 3,0/3,9 x In; starting torque 1,8/1,4 x Mn; Tilting moment 2,0/2,0 x Mn
Efficiency at nominal load 62%/75%
Power values correspond to basic design (constant torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø24 x 50 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6205.ZZ.C3; Camp BS: 6205.ZZ.C3; moment of inertia 0,0028 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
0,37/0,75 kW; S1; 705/1385 1/min; 400V ∆/YY 50 Hz 3AC; 1,7/1,7 A; 5,01/5,17 Nm
attracting current 3,0/4,2 x In; starting torque 2,1/1,5 x Mn; Tilting moment 2,3/1,8 x Mn
Efficiency at nominal load 55%/73%
Power values correspond to basic design (constant torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø24 x 50 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6205.ZZ.C3; Camp BS: 6205.ZZ.C3; moment of inertia 0,0025 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
1,40/2,00 kW; S1; 1405/2750 1/min; 400V ∆/YY 50 Hz 3AC; 2,8/3,1 A; 9,52/6,94 Nm
Power values correspond to basic design (constant torque)
attracting current 4,4/4,4 x In; starting torque 1,8/1,8 x Mn; tilting moment 2,2/2,2 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø24 x 50 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6205.ZZ.C3; Camp BS: 6205.ZZ.C3; moment of inertia 0,0028 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010
1,10/1,40 kW; S1; 1410/2785 1/min; 400V ∆/YY 50 Hz 3AC; 2,8/3,1 A; 7,45/4,80 Nm
Power values correspond to basic design (constant torque)
attracting current 4,4/4,5 x In; starting torque 1,6/1,7 x Mn; tilting moment 2,1/2,1 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø24 x 50 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6205.ZZ.C3; Camp BS: 6205.ZZ.C3; moment of inertia 0,0023 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010
attracting current 3,7/4,1 x In; starting torque 2,0/1,5 x Mn; Tilting moment 2,2/2,4 x Mn
Efficiency at nominal load [%] 63,7/66,5
Power values correspond to basic design (constant torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø19 x 40 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; moment of inertia 0,001578 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
0,30/0,55 kW; S1; 660/1350 1/min; 400V ∆/YY 50 Hz 3AC; 1,5/1,4 A; 4,34/3,89 Nm
attracting current 2,0/2,7 x In; starting torque 1,5/1,5 x Mn; Tilting moment 1,5/1,5 x Mn
Efficiency at nominal load 48%/64%
Power values correspond to basic design (constant torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø19 x 40 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; moment of inertia 0,00207 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
0,75/0,95 kW; S1; 1360/2780 min-1; 400V Y/YY 50 Hz 3AC 2,1/2,5 A; 5,23/3,26 Nm
attracting current 3,1/3,8 x In; starting torque 1,7/1,9 x Mn; Tilting moment 1,8/2,0 x Mn
Efficiency at nominal load 65%/60%
Power values fan design (square torque)
0,25/1,00 kW; S1; 1370/2780 1/min; 400VY/YY 50 Hz 3AC; 0,75/2,32 A; 1,75/3,44 Nm
attracting current 3,0/3,8 x In; starting torque 1,6/1,9 x Mn; tilting moment 1,7/2,0 Mn
Power values correspond to fan design (square torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø19 x 40 mm; heat class 155(F); Housing material up to frame size 132 aluminium, from frame size 160 grey cast iron; rated power at coolant temperature -20...40° C and up to 1000 m above NN; Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; moment of inertia 0,001874 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
0,22/0,40 kW; S1; 670/1350 1/min; 400V ∆/YY 50 Hz 3AC; 1,3/1,1 A; 3,13/2,83 Nm
attracting current 2,0/2,8 x In; starting torque 1,5/1,5 x Mn; Tilting moment 1,6/1,5 x Mn
Efficiency at nominal load 46%/60%
Power values correspond to basic design (constant torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø19 x 40 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; moment of inertia 0,001693 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010