ORIENTAL MOTOR
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 75
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC2.5 VAC※: Continuous
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.8 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz / 0.43 A / 43 W
single-Phase 100 VAC / 60 Hz / 0.53 A / 53 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 100 VAC / 50 Hz / 0.3 A / 21 W
single-Phase 100 VAC / 60 Hz / 0.35 A / 22 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60 Hz: 20 mN·m (Torque Setting VoltageDC1.8 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 3 N·m
60 Hz: 3 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.89 N·m
60 Hz: 0.99 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 2.8 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 100 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60Hz: 1 W (Torque Setting VoltageDC1.8 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 36 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 11 mN·m (Torque Setting VoltageDC1.8 VAC※) - Permissible Inertia J: 155×10-4 kg·m2
- capacitor: Product name: CH70CFAUL2, Capacity: 7 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 90
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC2.5 VAC※: Continuous
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.8 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz / 0.43 A / 43 W
single-Phase 100 VAC / 60 Hz / 0.53 A / 53 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 100 VAC / 50 Hz / 0.3 A / 21 W
single-Phase 100 VAC / 60 Hz / 0.35 A / 22 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60 Hz: 20 mN·m (Torque Setting VoltageDC1.8 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 3 N·m
60 Hz: 3 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 1.1 N·m
60 Hz: 1.2 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 2.8 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 100 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60Hz: 1 W (Torque Setting VoltageDC1.8 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 36 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 11 mN·m (Torque Setting VoltageDC1.8 VAC※) - Permissible Inertia J: 155×10-4 kg·m2
- capacitor: Product name: CH70CFAUL2, Capacity: 7 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 90
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz / 0.49 A / 53 W
single-Phase 115 VAC / 60 Hz / 0.51 A / 58 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 110 VAC / 60 Hz / 0.31 A / 22 W
single-Phase 115 VAC / 60 Hz / 0.33 A / 24 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※)
single-Phase 115 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 3 N·m
- gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 1.5 N·m
- Maximum Output Power (5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 110 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※)
single-Phase 115 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※) - Permissible Inertia J: 155×10-4 kg·m2
- capacitor: Product name: CH60CFAUL2, Capacity: 6 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 9
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 100 VAC / 50 Hz / Torque Setting VoltageDC2.5 VAC※: Continuous
single-Phase 100 VAC / 60 Hz / Torque Setting VoltageDC1.8 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz / 0.43 A / 43 W
single-Phase 100 VAC / 60 Hz / 0.53 A / 53 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 100 VAC / 50 Hz / 0.3 A / 21 W
single-Phase 100 VAC / 60 Hz / 0.35 A / 22 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60 Hz: 20 mN·m (Torque Setting VoltageDC1.8 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 0.51 N·m
60 Hz: 0.51 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.13 N·m
60 Hz: 0.15 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 2.8 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 100 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 100 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60Hz: 1 W (Torque Setting VoltageDC1.8 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 36 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 100 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.5 VAC※)
single-Phase 100 VAC / 60 Hz: 900 r/min / 11 mN·m (Torque Setting VoltageDC1.8 VAC※) - Permissible Inertia J: 5×10-4 kg·m2
- capacitor: Product name: CH70CFAUL2, Capacity: 7 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 9
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 110 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous
single-Phase 115 VAC / 60 Hz / Torque Setting VoltageDC1.7 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz / 0.49 A / 53 W
single-Phase 115 VAC / 60 Hz / 0.51 A / 58 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 110 VAC / 60 Hz / 0.31 A / 22 W
single-Phase 115 VAC / 60 Hz / 0.33 A / 24 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※)
single-Phase 115 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.7 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 60 Hz: 0.51 N·m
- gearhead Output Shaft Starting Torque (Continuous Service Rating): 60 Hz: 0.18 N·m
- Maximum Output Power (5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 115 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 110 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※)
single-Phase 115 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.7 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 110 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※)
single-Phase 115 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.7 VAC※) - Permissible Inertia J: 5×10-4 kg·m2
- capacitor: Product name: CH60CFAUL2, Capacity: 6 µF, Rated voltage: 250 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 100
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC2.2 VAC※: Continuous
single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous
single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC2.2 VAC※: Continuous
single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz / 0.23 A / 49 W
single-Phase 220 VAC / 60 Hz / 0.25 A / 55 W
single-Phase 230 VAC / 50 Hz / 0.25 A / 54 W
single-Phase 230 VAC / 60 Hz / 0.27 A / 60 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 220 VAC / 50 Hz / 0.15 A / 23 W
single-Phase 220 VAC / 60 Hz / 0.16 A / 24 W
single-Phase 230 VAC / 50 Hz / 0.16 A / 26 W
single-Phase 230 VAC / 60 Hz / 0.17 A / 27 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 220 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 220 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 220 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.6 VAC※)
single-Phase 230 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 230 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.6 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 3 N·m
60 Hz: 3 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 1.2 N·m
60 Hz: 1.7 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 2.8 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 220 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 50 Hz: 3 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 220 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.2 VAC※)
single-Phase 220 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.6 VAC※)
single-Phase 230 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.2 VAC※)
single-Phase 230 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.6 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 750 r/min / 36 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 220 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 230 VAC / 50 Hz: 750 r/min / 39 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 230 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 220 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 220 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.6 VAC※)
single-Phase 230 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 230 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.6 VAC※) - Permissible Inertia J: 155×10-4 kg·m2
- capacitor: Product name: CH15BFAUL, Capacity: 1.5 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 12.5
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC2.2 VAC※: Continuous
single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz / 0.23 A / 45 W
single-Phase 200 VAC / 60 Hz / 0.28 A / 55 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 200 VAC / 50 Hz / 0.15 A / 22 W
single-Phase 200 VAC / 60 Hz / 0.18 A / 24 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 200 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 200 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 200 VAC / 60 Hz: 20 mN·m (Torque Setting VoltageDC1.6 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 0.71 N·m
60 Hz: 0.71 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.18 N·m
60 Hz: 0.2 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 3 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 200 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 200 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.2 VAC※)
single-Phase 200 VAC / 60Hz: 1 W (Torque Setting VoltageDC1.6 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 750 r/min / 39 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 200 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 200 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 200 VAC / 60 Hz: 900 r/min / 11 mN·m (Torque Setting VoltageDC1.6 VAC※) - Permissible Inertia J: 9.6×10-4 kg·m2
- capacitor: Product name: CH18BFAUL, Capacity: 1.8 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 120
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC2.2 VAC※: Continuous
single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous
single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC2.2 VAC※: Continuous
single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz / 0.23 A / 49 W
single-Phase 220 VAC / 60 Hz / 0.25 A / 55 W
single-Phase 230 VAC / 50 Hz / 0.25 A / 54 W
single-Phase 230 VAC / 60 Hz / 0.27 A / 60 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 220 VAC / 50 Hz / 0.15 A / 23 W
single-Phase 220 VAC / 60 Hz / 0.16 A / 24 W
single-Phase 230 VAC / 50 Hz / 0.16 A / 26 W
single-Phase 230 VAC / 60 Hz / 0.17 A / 27 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 220 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 220 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 220 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.6 VAC※)
single-Phase 230 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 230 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.6 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 3 N·m
60 Hz: 3 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 1.4 N·m
60 Hz: 2 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 2.8 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 220 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 50 Hz: 3 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 220 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.2 VAC※)
single-Phase 220 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.6 VAC※)
single-Phase 230 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.2 VAC※)
single-Phase 230 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.6 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 750 r/min / 36 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 220 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 230 VAC / 50 Hz: 750 r/min / 39 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 230 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 220 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 220 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.6 VAC※)
single-Phase 230 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 230 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.6 VAC※) - Permissible Inertia J: 155×10-4 kg·m2
- capacitor: Product name: CH15BFAUL, Capacity: 1.5 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 150
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 200 VAC / 50 Hz / Torque Setting VoltageDC2.2 VAC※: Continuous
single-Phase 200 VAC / 60 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz / 0.23 A / 45 W
single-Phase 200 VAC / 60 Hz / 0.28 A / 55 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 200 VAC / 50 Hz / 0.15 A / 22 W
single-Phase 200 VAC / 60 Hz / 0.18 A / 24 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 200 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 200 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 200 VAC / 60 Hz: 20 mN·m (Torque Setting VoltageDC1.6 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 3 N·m
60 Hz: 3 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 1.8 N·m
60 Hz: 2 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 3 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 200 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 200 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.2 VAC※)
single-Phase 200 VAC / 60Hz: 1 W (Torque Setting VoltageDC1.6 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 200 VAC / 50 Hz: 750 r/min / 39 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 200 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 200 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 200 VAC / 60 Hz: 900 r/min / 11 mN·m (Torque Setting VoltageDC1.6 VAC※) - Permissible Inertia J: 155×10-4 kg·m2
- capacitor: Product name: CH18BFAUL, Capacity: 1.8 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 15
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC2.2 VAC※: Continuous
single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous
single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC2.2 VAC※: Continuous
single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz / 0.23 A / 49 W
single-Phase 220 VAC / 60 Hz / 0.25 A / 55 W
single-Phase 230 VAC / 50 Hz / 0.25 A / 54 W
single-Phase 230 VAC / 60 Hz / 0.27 A / 60 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 220 VAC / 50 Hz / 0.15 A / 23 W
single-Phase 220 VAC / 60 Hz / 0.16 A / 24 W
single-Phase 230 VAC / 50 Hz / 0.16 A / 26 W
single-Phase 230 VAC / 60 Hz / 0.17 A / 27 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 220 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 220 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 220 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.6 VAC※)
single-Phase 230 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 230 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.6 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 0.85 N·m
60 Hz: 0.85 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.22 N·m
60 Hz: 0.3 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 2.8 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 220 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 50 Hz: 3 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 220 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.2 VAC※)
single-Phase 220 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.6 VAC※)
single-Phase 230 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.2 VAC※)
single-Phase 230 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.6 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 750 r/min / 36 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 220 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 230 VAC / 50 Hz: 750 r/min / 39 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 230 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 220 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 220 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.6 VAC※)
single-Phase 230 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 230 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.6 VAC※) - Permissible Inertia J: 13.9×10-4 kg·m2
- capacitor: Product name: CH15BFAUL, Capacity: 1.5 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 180
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC2.2 VAC※: Continuous
single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous
single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC2.2 VAC※: Continuous
single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz / 0.23 A / 49 W
single-Phase 220 VAC / 60 Hz / 0.25 A / 55 W
single-Phase 230 VAC / 50 Hz / 0.25 A / 54 W
single-Phase 230 VAC / 60 Hz / 0.27 A / 60 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 220 VAC / 50 Hz / 0.15 A / 23 W
single-Phase 220 VAC / 60 Hz / 0.16 A / 24 W
single-Phase 230 VAC / 50 Hz / 0.16 A / 26 W
single-Phase 230 VAC / 60 Hz / 0.17 A / 27 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 220 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 220 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 220 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.6 VAC※)
single-Phase 230 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 230 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.6 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 3 N·m
60 Hz: 3 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 2.1 N·m
60 Hz: 3 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 2.8 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 220 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 50 Hz: 3 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 220 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.2 VAC※)
single-Phase 220 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.6 VAC※)
single-Phase 230 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.2 VAC※)
single-Phase 230 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.6 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 750 r/min / 36 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 220 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 230 VAC / 50 Hz: 750 r/min / 39 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 230 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 220 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 220 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.6 VAC※)
single-Phase 230 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 230 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.6 VAC※) - Permissible Inertia J: 155×10-4 kg·m2
- capacitor: Product name: CH15BFAUL, Capacity: 1.5 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).
- Frame Size: 60 mm
- Shaft/Gear Type: Combination
- Gear Ratio: 18
- Rotation Direction: same direction as the motor shaft
- Service Rating (When Locked): single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC5.0 VAC※: 5Minutes
single-Phase 220 VAC / 50 Hz / Torque Setting VoltageDC2.2 VAC※: Continuous
single-Phase 220 VAC / 60 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous
single-Phase 230 VAC / 50 Hz / Torque Setting VoltageDC2.2 VAC※: Continuous
single-Phase 230 VAC / 60 Hz / Torque Setting VoltageDC1.6 VAC※: Continuous - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz / 0.23 A / 49 W
single-Phase 220 VAC / 60 Hz / 0.25 A / 55 W
single-Phase 230 VAC / 50 Hz / 0.25 A / 54 W
single-Phase 230 VAC / 60 Hz / 0.27 A / 60 W - Voltage/ Frequency/ Maximum Input Current/ Maximum Power Consumption(Continuous Service Rating): single-Phase 220 VAC / 50 Hz / 0.15 A / 23 W
single-Phase 220 VAC / 60 Hz / 0.16 A / 24 W
single-Phase 230 VAC / 50 Hz / 0.16 A / 26 W
single-Phase 230 VAC / 60 Hz / 0.17 A / 27 W - Starting Torque (Motor Shaft, 5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 220 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 50 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 60 Hz: 70 mN·m (Torque Setting VoltageDC5.0 VAC※) - Starting Torque (Motor Shaft, Continuous Service Rating): single-Phase 220 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 220 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.6 VAC※)
single-Phase 230 VAC / 50 Hz: 18 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 230 VAC / 60 Hz: 25 mN·m (Torque Setting VoltageDC1.6 VAC※) - gearhead Output Shaft Starting Torque (5 Minutes Service Rating): 50 Hz: 1 N·m
60 Hz: 1 N·m - gearhead Output Shaft Starting Torque (Continuous Service Rating): 50 Hz: 0.26 N·m
60 Hz: 0.36 N·m - Maximum Output Power (5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 2.8 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 220 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 50 Hz: 3 W (Torque Setting VoltageDC5.0 VAC※)
single-Phase 230 VAC / 60 Hz: 3.5 W (Torque Setting VoltageDC5.0 VAC※) - Maximum Output Power (Continuous Service Rating): single-Phase 220 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.2 VAC※)
single-Phase 220 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.6 VAC※)
single-Phase 230 VAC / 50Hz: 0.8 W (Torque Setting VoltageDC2.2 VAC※)
single-Phase 230 VAC / 60Hz: 1.2 W (Torque Setting VoltageDC1.6 VAC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, 5 Minutes Service Rating): single-Phase 220 VAC / 50 Hz: 750 r/min / 36 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 220 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 230 VAC / 50 Hz: 750 r/min / 39 mN·m (Torque Setting Voltage5.0 VDC※)
single-Phase 230 VAC / 60 Hz: 900 r/min / 38 mN·m (Torque Setting Voltage5.0 VDC※) - Speed at Maximum Output Power/ Torque at Maximum Output Power(Motor Shaft, Continuous Service Rating): single-Phase 220 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 220 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.6 VAC※)
single-Phase 230 VAC / 50 Hz: 750 r/min / 10 mN·m (Torque Setting VoltageDC2.2 VAC※)
single-Phase 230 VAC / 60 Hz: 900 r/min / 13 mN·m (Torque Setting VoltageDC1.6 VAC※) - Permissible Inertia J: 20×10-4 kg·m2
- capacitor: Product name: CH15BFAUL, Capacity: 1.5 µF, Rated voltage: 450 VAC
- Overheat Protective Device Type: Thermal protector
- Mass: 1.1 kg (ギヤヘッド含む)
- Circuit Mass: 0.18 kg
• The UL mark apply to the Circuit.
• The CE mark apply to the Motor and the Circuit.
• Various safety standards certifications have been obtained for an individual motor product name and an individual circuit product names.
※ The torque setting voltage indicates the value when the external voltage select switch is set to the "5 V" position.
• This indicates that there is a built-in thermal protector (automatic return type). If a motor overheats for any reason, the thermal protector is activated and the motor is stopped.
• When moving horizontally under a load with a guide, etc., make sure that the load mass is less than the maximum transportable mass.
Output torque at times other than startup can be determined using a calculation formula.Please refer to "Output torque" (Other specifications).