IP23 high-speed motors KHH
Items 1 - 32 of 32
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3400 min-1
- RATED FREQUENCY: 57,1 Hz
- OUTPUT POWER: 114 kW (S1) / 148 kW (S6-40%)
- RATED TORQUE: 320 Nm (S1) / 416 Nm (S6-40%)
- RATED CURRENT: 198 A (S1) / 252 A (S6-40%)
- EFFICIENCY: 94,5 %
- CONSTANT-POWER RANGE max.: 7500 min-1 (S1) / 6800 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 119 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 6000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,31 kgm2
- ARTICLE WEIGHT: 385,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4300 min-1
- RATED FREQUENCY: 72,0 Hz
- OUTPUT POWER: 130 kW (S1) / 170 kW (S6-40%)
- RATED TORQUE: 290 Nm (S1) / 377 Nm (S6-40%)
- RATED CURRENT: 215 A (S1) / 280 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 7500 min-1 (S1) / 7500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 152 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 6000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,31 kgm2
- ARTICLE WEIGHT: 385,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3420 min-1
- RATED FREQUENCY: 57,5 Hz
- OUTPUT POWER: 115 kW (S1) / 150 kW (S6-40%)
- RATED TORQUE: 320 Nm (S1) / 416 Nm (S6-40%)
- RATED CURRENT: 173 A (S1) / 220 A (S6-40%)
- EFFICIENCY: 94,5 %
- CONSTANT-POWER RANGE max.: 7500 min-1 (S1) / 6850 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 121 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 6000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,31 kgm2
- ARTICLE WEIGHT: 385,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4240 min-1
- RATED FREQUENCY: 71,0 Hz
- OUTPUT POWER: 129 kW (S1) / 167 kW (S6-40%)
- RATED TORQUE: 290 Nm (S1) / 377 Nm (S6-40%)
- RATED CURRENT: 184 A (S1) / 240 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 7500 min-1 (S1) / 7500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 147 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 6000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,31 kgm2
- ARTICLE WEIGHT: 385,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3420 min-1
- RATED FREQUENCY: 57,4 Hz
- OUTPUT POWER: 132 kW (S1) / 172 kW (S6-40%)
- RATED TORQUE: 370 Nm (S1) / 481 Nm (S6-40%)
- RATED CURRENT: 227 A (S1) / 290 A (S6-40%)
- EFFICIENCY: 94,5 %
- CONSTANT-POWER RANGE max.: 7500 min-1 (S1) / 7100 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 144 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 6000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,36 kgm2
- ARTICLE WEIGHT: 425,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4280 min-1
- RATED FREQUENCY: 71,7 Hz
- OUTPUT POWER: 150 kW (S1) / 195 kW (S6-40%)
- RATED TORQUE: 335 Nm (S1) / 435 Nm (S6-40%)
- RATED CURRENT: 250 A (S1) / 318 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 7500 min-1 (S1) / 7500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 179 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 6000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,36 kgm2
- ARTICLE WEIGHT: 425,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3370 min-1
- RATED FREQUENCY: 56,6 Hz
- OUTPUT POWER: 130 kW (S1) / 170 kW (S6-40%)
- RATED TORQUE: 370 Nm (S1) / 481 Nm (S6-40%)
- RATED CURRENT: 195 A (S1) / 249 A (S6-40%)
- EFFICIENCY: 94,5 %
- CONSTANT-POWER RANGE max.: 7500 min-1 (S1) / 7000 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 140 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 6000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,36 kgm2
- ARTICLE WEIGHT: 425,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4430 min-1
- RATED FREQUENCY: 74,2 Hz
- OUTPUT POWER: 155 kW (S1) / 202 kW (S6-40%)
- RATED TORQUE: 335 Nm (S1) / 435 Nm (S6-40%)
- RATED CURRENT: 225 A (S1) / 286 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 7500 min-1 (S1) / 7500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 191 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 6000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,36 kgm2
- ARTICLE WEIGHT: 425,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3380 min-1
- RATED FREQUENCY: 56,7 Hz
- OUTPUT POWER: 152 kW (S1) / 198 kW (S6-40%)
- RATED TORQUE: 430 Nm (S1) / 558 Nm (S6-40%)
- RATED CURRENT: 260 A (S1) / 332 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 7500 min-1 (S1) / 7400 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 172 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 6000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,42 kgm2
- ARTICLE WEIGHT: 472,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4050 min-1
- RATED FREQUENCY: 67,9 Hz
- OUTPUT POWER: 165 kW (S1) / 215 kW (S6-40%)
- RATED TORQUE: 390 Nm (S1) / 506 Nm (S6-40%)
- RATED CURRENT: 270 A (S1) / 350 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 7500 min-1 (S1) / 7500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 202 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 6000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,42 kgm2
- ARTICLE WEIGHT: 472,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3500 min-1
- RATED FREQUENCY: 58,7 Hz
- OUTPUT POWER: 157 kW (S1) / 205 kW (S6-40%)
- RATED TORQUE: 430 Nm (S1) / 558 Nm (S6-40%)
- RATED CURRENT: 234 A (S1) / 299 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 7500 min-1 (S1) / 7500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 184 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 6000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,42 kgm2
- ARTICLE WEIGHT: 472,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 4140 min-1
- RATED FREQUENCY: 69,4 Hz
- OUTPUT POWER: 169 kW (S1) / 220 kW (S6-40%)
- RATED TORQUE: 390 Nm (S1) / 506 Nm (S6-40%)
- RATED CURRENT: 240 A (S1) / 310 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 7500 min-1 (S1) / 7500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 212 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 6000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,42 kgm2
- ARTICLE WEIGHT: 472,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3120 min-1
- RATED FREQUENCY: 52,3 Hz
- OUTPUT POWER: 170 kW (S1) / 220 kW (S6-40%)
- RATED TORQUE: 520 Nm (S1) / 673 Nm (S6-40%)
- RATED CURRENT: 292 A (S1) / 373 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 7500 min-1 (S1) / 7500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 194 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 6000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,48 kgm2
- ARTICLE WEIGHT: 530,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS2
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3900 min-1
- RATED FREQUENCY: 65,3 Hz
- OUTPUT POWER: 190 kW (S1) / 247 kW (S6-40%)
- RATED TORQUE: 465 Nm (S1) / 605 Nm (S6-40%)
- RATED CURRENT: 307 A (S1) / 384 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 7500 min-1 (S1) / 7500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 247 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 6000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,48 kgm2
- ARTICLE WEIGHT: 530,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3190 min-1
- RATED FREQUENCY: 53,5 Hz
- OUTPUT POWER: 174 kW (S1) / 225 kW (S6-40%)
- RATED TORQUE: 520 Nm (S1) / 673 Nm (S6-40%)
- RATED CURRENT: 260 A (S1) / 332 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 7500 min-1 (S1) / 7500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 202 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 6000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,48 kgm2
- ARTICLE WEIGHT: 530,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS2
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 2
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3920 min-1
- RATED FREQUENCY: 65,7 Hz
- OUTPUT POWER: 191 kW (S1) / 248 kW (S6-40%)
- RATED TORQUE: 465 Nm (S1) / 605 Nm (S6-40%)
- RATED CURRENT: 269 A (S1) / 336 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 7500 min-1 (S1) / 7500 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 248 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 6000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,48 kgm2
- ARTICLE WEIGHT: 530,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS4
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 4
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2380 min-1
- RATED FREQUENCY: 79,9 Hz
- OUTPUT POWER: 118 kW (S1) / 154 kW (S6-40%)
- RATED TORQUE: 475 Nm (S1) / 617 Nm (S6-40%)
- RATED CURRENT: 205 A (S1) / 264 A (S6-40%)
- EFFICIENCY: 94,5 %
- CONSTANT-POWER RANGE max.: 5800 min-1 (S1) / 4400 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 90,2 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 5000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,53 kgm2
- ARTICLE WEIGHT: 385,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS4
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 4
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3040 min-1
- RATED FREQUENCY: 101,9 Hz
- OUTPUT POWER: 140 kW (S1) / 182 kW (S6-40%)
- RATED TORQUE: 440 Nm (S1) / 572 Nm (S6-40%)
- RATED CURRENT: 238 A (S1) / 308 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 6600 min-1 (S1) / 5300 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 129 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 5000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,53 kgm2
- ARTICLE WEIGHT: 385,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS4
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 4
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2350 min-1
- RATED FREQUENCY: 78,8 Hz
- OUTPUT POWER: 117 kW (S1) / 152 kW (S6-40%)
- RATED TORQUE: 475 Nm (S1) / 617 Nm (S6-40%)
- RATED CURRENT: 176 A (S1) / 226 A (S6-40%)
- EFFICIENCY: 94,5 %
- CONSTANT-POWER RANGE max.: 5750 min-1 (S1) / 4350 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 88,1 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 5000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,53 kgm2
- ARTICLE WEIGHT: 385,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS4
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 4
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2910 min-1
- RATED FREQUENCY: 97,7 Hz
- OUTPUT POWER: 134 kW (S1) / 174 kW (S6-40%)
- RATED TORQUE: 440 Nm (S1) / 572 Nm (S6-40%)
- RATED CURRENT: 198 A (S1) / 257 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 6300 min-1 (S1) / 5050 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 117 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 5000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,53 kgm2
- ARTICLE WEIGHT: 385,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS4
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 4
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2460 min-1
- RATED FREQUENCY: 82,5 Hz
- OUTPUT POWER: 142 kW (S1) / 184 kW (S6-40%)
- RATED TORQUE: 550 Nm (S1) / 715 Nm (S6-40%)
- RATED CURRENT: 246 A (S1) / 315 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 6100 min-1 (S1) / 4600 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 113 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 5000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,60 kgm2
- ARTICLE WEIGHT: 425,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS4
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 4
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3030 min-1
- RATED FREQUENCY: 101,6 Hz
- OUTPUT POWER: 162 kW (S1) / 210 kW (S6-40%)
- RATED TORQUE: 510 Nm (S1) / 663 Nm (S6-40%)
- RATED CURRENT: 274 A (S1) / 355 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 6500 min-1 (S1) / 4600 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 129 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 5000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,60 kgm2
- ARTICLE WEIGHT: 425,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS4
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 4
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2360 min-1
- RATED FREQUENCY: 79,1 Hz
- OUTPUT POWER: 136 kW (S1) / 177 kW (S6-40%)
- RATED TORQUE: 550 Nm (S1) / 715 Nm (S6-40%)
- RATED CURRENT: 205 A (S1) / 263 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 5850 min-1 (S1) / 4400 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 104 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 5000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,60 kgm2
- ARTICLE WEIGHT: 425,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS4
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 4
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3070 min-1
- RATED FREQUENCY: 103,1 Hz
- OUTPUT POWER: 164 kW (S1) / 213 kW (S6-40%)
- RATED TORQUE: 510 Nm (S1) / 663 Nm (S6-40%)
- RATED CURRENT: 242 A (S1) / 313 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 6600 min-1 (S1) / 4650 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 132 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 5000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,60 kgm2
- ARTICLE WEIGHT: 425,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS4
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 4
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2410 min-1
- RATED FREQUENCY: 80,9 Hz
- OUTPUT POWER: 163 kW (S1) / 212 kW (S6-40%)
- RATED TORQUE: 645 Nm (S1) / 839 Nm (S6-40%)
- RATED CURRENT: 282 A (S1) / 362 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 6300 min-1 (S1) / 4700 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 133 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 5000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,68 kgm2
- ARTICLE WEIGHT: 472,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS4
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 4
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2960 min-1
- RATED FREQUENCY: 99,2 Hz
- OUTPUT POWER: 186 kW (S1) / 242 kW (S6-40%)
- RATED TORQUE: 600 Nm (S1) / 780 Nm (S6-40%)
- RATED CURRENT: 314 A (S1) / 405 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 6800 min-1 (S1) / 5200 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 168 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 5000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,68 kgm2
- ARTICLE WEIGHT: 472,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS4
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 4
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2450 min-1
- RATED FREQUENCY: 82,1 Hz
- OUTPUT POWER: 166 kW (S1) / 215 kW (S6-40%)
- RATED TORQUE: 645 Nm (S1) / 839 Nm (S6-40%)
- RATED CURRENT: 249 A (S1) / 319 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 6400 min-1 (S1) / 4800 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 138 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 5000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,68 kgm2
- ARTICLE WEIGHT: 472,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS4
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 4
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2950 min-1
- RATED FREQUENCY: 98,9 Hz
- OUTPUT POWER: 185 kW (S1) / 240 kW (S6-40%)
- RATED TORQUE: 600 Nm (S1) / 780 Nm (S6-40%)
- RATED CURRENT: 272 A (S1) / 350 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 6800 min-1 (S1) / 5200 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 166 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 5000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,68 kgm2
- ARTICLE WEIGHT: 472,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS4
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 4
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2450 min-1
- RATED FREQUENCY: 82,2 Hz
- OUTPUT POWER: 200 kW (S1) / 260 kW (S6-40%)
- RATED TORQUE: 780 Nm (S1) / 1014 Nm (S6-40%)
- RATED CURRENT: 350 A (S1) / 440 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 6700 min-1 (S1) / 5000 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 173 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 5000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,82 kgm2
- ARTICLE WEIGHT: 530,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS4
- RATED VOLTAGE: 400 V
- NUMBER OF POLES: 4
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3070 min-1
- RATED FREQUENCY: 102,9 Hz
- OUTPUT POWER: 235 kW (S1) / 305 kW (S6-40%)
- RATED TORQUE: 730 Nm (S1) / 948 Nm (S6-40%)
- RATED CURRENT: 395 A (S1) / 510 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 7000 min-1 (S1) / 5300 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 215 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 5000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,82 kgm2
- ARTICLE WEIGHT: 530,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS4
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 4
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 2470 min-1
- RATED FREQUENCY: 82,7 Hz
- OUTPUT POWER: 202 kW (S1) / 262 kW (S6-40%)
- RATED TORQUE: 780 Nm (S1) / 1014 Nm (S6-40%)
- RATED CURRENT: 306 A (S1) / 385 A (S6-40%)
- EFFICIENCY: 95,0 %
- CONSTANT-POWER RANGE max.: 6750 min-1 (S1) / 5050 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 176 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 5000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,82 kgm2
- ARTICLE WEIGHT: 530,00 kg
- PROTECTION DEGREE: IP21
- SERIE: HIGH SPEED / RS4
- RATED VOLTAGE: 460 V
- NUMBER OF POLES: 4
- DUTY TYPE: S1 / S6-40%
- RATED SPEED: 3030 min-1
- RATED FREQUENCY: 101,4 Hz
- OUTPUT POWER: 231 kW (S1) / 300 kW (S6-40%)
- RATED TORQUE: 730 Nm (S1) / 948 Nm (S6-40%)
- RATED CURRENT: 340 A (S1) / 437 A (S6-40%)
- EFFICIENCY: 95,5 %
- CONSTANT-POWER RANGE max.: 6900 min-1 (S1) / 5250 min-1 (S6-40%)
- MAX. POWER AT MAX. SPEED: 210 kW
- COOLING: IC06 (with filter on request)
- INSULATION CLASS: F
- AMBIENT CONDITIONS: 0 to +40 °C, 1000 m ABOVE SEA LEVEL
- MAX. MECHANICAL SPEED: 7500 min-1; may be further limited by encoder feedback or brake
- DURCHSCHN. BEARINGSLEBENSDAUER D10h: 12000 h at mean operating speed ≤ 5000 min-1
- HINWEIS: high performance bearings; Radial or axial loads are not permitted. The maximum permissible speed shall be assessed on an installation-specific basis.
- MOMENT OF INERTIA J: 0,82 kgm2
- ARTICLE WEIGHT: 530,00 kg
Items 1 - 32 of 32