3AC pole-changing motors
Standard three-phase motors
2,00/2,60 kW; S1; 1395/2810 1/min; 400V ∆/YY 50 Hz 3AC; 4,2/5,3 A; 13,7/8,8 Nm
Power values correspond to basic version D / YY, 6 clamps (constant torque)
attracting current 4,8/4,7 x In; starting torque 1,6/1,8 x Mn; tilting moment 2,1/2,4 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø28 x 60 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6206.ZZ.C3; Camp BS: 6206.ZZ.C3; moment of inertia 0,006 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010
Power values correspond to fan design (square torque)
attracting current 5,5/7,5 x In; starting torque 1,2/1,8 x Mn; tilting moment 1,8 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; heat class 155(F); with PTC resistor PTC 150°C
Housing material up to frame size 132 aluminium, from frame size 160 grey cast iron; Colour of RAL7030
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6206.ZZ.C3; Camp BS: 6206.ZZ.C3 floating stock
half-wedge weighting species; vibration stage "A"; Fan blades plastic
- Foot mounting: Removable feet (terminal box can be repositioned).
0,60/1,70 kW; S1; 950/1410 1/min; 400V ∆/YY 50 Hz 3AC; 2,0/4,2 A; 6,3/11,5 Nm
Power values correspond to fan version D / YY, 6 clamps (square torque)
attracting current 3,4/4,3 x In; starting torque 1,3/1,4 x Mn; tilting moment 2,1/2,2 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø28 x 60 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6206.ZZ.C3; Camp BS: 6206.ZZ.C3; moment of inertia 0,0088 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010
Power values correspond to fan design (square torque)
attracting current 6,0/7,0 x In; starting torque 1,6/1,8 x Mn; tilting moment 1,8 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; Heat class 155(F)
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; Moment of inertia 0,0009 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic
- Foot mounting: Removable feet (terminal box can be repositioned).
Power values correspond to fan design (square torque)
attracting current 6,0/7,0 x In; starting torque 1,6/1,8 x Mn; tilting moment 1,8 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; Heat class 155(F)
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; Moment of inertia 0,0009 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic
- Foot mounting: Removable feet (terminal box can be repositioned).
0,44/1,80 kW; S1; 680/1400 1/min; 400V ∆/YY 50 Hz 3AC; 1,3/3,9 A; 6,18/12,3 Nm
attracting current 2,7/4,5 x In; starting torque 1,2/1,5 x Mn; Tilting moment 1,9/1,9 x Mn
Efficiency at nominal load 64%/78%
Power values correspond to fan design (square torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø28 x 60 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6206.ZZ.C3; Camp BS: 6206.ZZ.C3; moment of inertia 0,0088 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
0,70/1,25 kW; S1; 715/1425 1/min; 400V ∆/YY 50 Hz 3AC; 2,8/2,7 A; 9,35/8,38 Nm
attracting current 3,6/5,1 x In; starting torque 2,2/1,7 x Mn; Tilting moment 2,8/2,5 x Mn
Efficiency at nominal load 64%/78%
Power values correspond to basic design (constant torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø28 x 60 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6206.ZZ.C3; Camp BS: 6206.ZZ.C3; moment of inertia 0,0088 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
Power values correspond to fan design (square torque)
attracting current 5/7,5 x In; starting torque 1,3/2,2 x Mn; tilting moment 2,2 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; Heat class 155(F)
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; Moment of inertia 0,0009 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic
- Foot mounting: Removable feet (terminal box can be repositioned).
- 2,50/3,30 kW
- S1
- 1380/2785 1/min
- 400V ∆/YY 50 Hz 3AC
- 4,2/5,3 A
- 17,3/11,3 Nm
- Power values correspond to basic design (constant torque)
- attracting current 4,8/4,9 x In
- starting torque 1,7/1,8 x Mn
- tilting moment 2,0/2,2 x Mn
- IEC 60034-1 design
- sound limit value according to IEC 60034-9
- shaft Ø28 x 60 mm
- heat class 155(F)
- in the case of B3 design, feet screwed to frame size132
- Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron
- Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6206.ZZ.C3
- Camp BS: 6206.ZZ.C3
- moment of inertia 0,0065 kgm2
- half-wedge weighting species
- vibration stage "A"
- terminal box layer at the top
- clamp/strand number 6
- the possibility of rotation of the terminal box yes
- Paint RAL5010
Power values correspond to fan design (square torque)
attracting current 5,5/7,5 x In; starting torque 1,3/1,8 x Mn; tilting moment 1,8 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; heat class 155(F); RAL7030
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6206.ZZ.C3; Camp BS: 6206.ZZ.C3; Moment of inertia 0,0009 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic
Protective device winding PTC 150°C
- Foot mounting: Removable feet (terminal box can be repositioned).
Power values correspond to fan design (square torque)
attracting current 6,0/7,0 x In; starting torque 1,6/1,8 x Mn; tilting moment 1,8 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; Heat class 155(F)
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; Moment of inertia 0,0009 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic
- Foot mounting: Removable feet (terminal box can be repositioned).
0,90/1,70 kW; S1; 715/1415 1/min; 400V ∆/YY 50 Hz 3AC; 3,2/3,7 A; 12,0/11,5 Nm
Power values correspond to basic design (constant torque)
attracting current 4,0/5,1 x In; starting torque 2,2/1,3 x Mn; tilting moment 3,1/2,3 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø28 x 60 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6206.ZZ.C3; Camp BS: 6206.ZZ.C3; moment of inertia 0,0094 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010
Power values correspond to fan design (square torque)
attracting current 5/7,5 x In; starting torque 1,3/2,2 x Mn; tilting moment 2,2 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; Heat class 155(F)
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; Moment of inertia 0,0009 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic
- Foot mounting: Removable feet (terminal box can be repositioned).
Power values correspond to basic design (constant torque)
attracting current 6,9/5,9 x In; starting torque 2,7/2,2 x Mn; tilting moment 2,2/2,6 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; heat class 155(F); RAL 5010/C3
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6306.ZZ.C3; Camp BS: 6306.ZZ.C3; Moment of inertia 0,0119 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic;
6 clamps
Power values correspond to fan design (square torque)
attracting current 5,5/7,5 x In; starting torque 1,4/1,4 x Mn; tilting moment 1,8 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; Heat class 155(F)
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; Moment of inertia 0,0009 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic
- Foot mounting: Removable feet (terminal box can be repositioned).
Power values correspond to Gbasic (constant torque)
attracting current 6,1/6,1 x In; starting torque 1,8/1,7 x Mn; tilting moment 2,6/2,6 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; Heat class 155(F)
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; Moment of inertia 0,0009 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic
Power values correspond to fan design (square torque)
attracting current 6,0/7,0 x In; starting torque 1,6/1,8 x Mn; tilting moment 1,8 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; Heat class 155(F)
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; Moment of inertia 0,0009 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic
- Foot mounting: Removable feet (terminal box can be repositioned).
Power values correspond to fan design (square torque)
attracting current 6,0/7,0 x In; starting torque 1,6/1,8 x Mn; tilting moment 1,8 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; Heat class 155(F)
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; Moment of inertia 0,0009 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic
- Foot mounting: Removable feet (terminal box can be repositioned).
Power values correspond to fan design (square torque)
attracting current 3,8/5,8 x In; starting torque 1,6/1,7 x Mn; tilting moment 2,2/2,5 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; heat class 155(F); RAL 5010/C3
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6306.ZZ.C3; Camp BS: 6306.ZZ.C3; Moment of inertia 0,0018 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic
Power values correspond to basic design (constant torque); 6 clamps
attracting current 4,6/5,4 x In; starting torque 2,5/1,4 x Mn; tilting moment 2,8/2,2 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; heat class 155(F); RAL 5010/C3
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6306.ZZ.C3; Camp BS: 6306.ZZ.C3; Moment of inertia 0,018 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic