1AC single-phase motors
Items 1 - 38 of 38
- Rated output P2 [kW]: 0.25
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Specified speed [min−1]: 1370
- Rated current [A]: 1.99
- Starting torque / rated torque: 2.50
- Frame size: 71
- Number of poles: 4
- Degree of protection: IP55
- Insulation class: F
- Ambient temperature: ≤ +40 °C
- Installation altitude up to [m]: 1000
- Vibration grade: N
- Mounting arrangement: Variants as selected
- Shaft end D × E [mm]: 14 × 30
- With run and start capacitors
- Dynamically balanced with half key
- Shaft end including key
- Removable feet; rotatable terminal box
- Rated output P2 [kW]: 0.25
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Rated speed [min−1]: 1340
- Rated current [A]: 2.5
- Rated torque [N·m]: 1.78
- Efficiency [%]: 56
- Power factor cos φ: 0.80
- Starting current / rated current: 2.0
- Starting torque / rated torque: 1.00
- Breakdown torque / rated torque: 1.70
- Moment of inertia J [kg·m²]: 0.00085
- Run capacitor [µF]: 10
- Frame size: 71
- Number of poles: 4
- Degree of protection: IP55
- Insulation class: F
- Motor weight, base design [kg]: 6.3
- Ambient temperature: -15…+40 °C
- Colour: RAL 5010
- Design standard: IEC 60034-1 / PN-EN 60034-1
- Mounting arrangement: Variants as selected
- Capacitor rated voltage [V]: 450
- Shaft end D × E [mm]: 14j6 × 30
- Bearings: 6203 2Z
- With run capacitor
- Further dimensions [mm]: D = 14j6; E = 30; F = 5h9; GA = 16; DW = M20; AC = 141; AD = 90; BL = 12; L = 245; LC = 283
- Foot dimensions [mm]: A = 112; B = 90; C = 45; CA = 88; H = 71 (−0.5); K = 7; K1 = 10; AA = 45; AB = 142; BB = 116; HA = 8; HD = 182
- Flange dimensions [mm] B5: R = 0; HB = 111; P = 160; M = 130; N = 110j6; S = 10; LA = 9; T = 3.5
- Flange dimensions [mm] B14A: R = 0; HB = 111; P = 105; M = 85; N = 70j6; S = M6; LE = 12; T = 2.5
- Flange dimensions [mm] B14B: R = 0; HB = 111; P = 140; M = 115; N = 95j6; S = M8; LE = 14; T = 3
- Rated output P2 [kW]: 1.10
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Rated speed [min−1]: 2780
- Rated current [A]: 6.4
- Rated torque [N·m]: 3.75
- Efficiency [%]: 76
- Power factor cos φ: 0.98
- Starting current / rated current: 3.5
- Starting torque / rated torque: 0.55
- Breakdown torque / rated torque: 1.8
- Moment of inertia J [kg·m²]: 0.00142
- Run capacitor [µF]: 30
- Frame size: 80
- Number of poles: 2
- Degree of protection: IP55
- Insulation class: F
- Motor weight, base design [kg]: 11.7
- Ambient temperature: -15…+40 °C
- Colour: RAL 5010
- Design standard: IEC 60034-1 / PN-EN 60034-1
- Mounting arrangement: Variants as selected
- Capacitor rated voltage [V]: 450
- Shaft end D × E [mm]: 19j6 × 40
- Bearings: 6204 2Z
- With run capacitor
- Further dimensions [mm]: D = 19j6; E = 40; F = 6h9; GA = 21.5; DW = M20; AC = 157; AD = 95; BL = 15; L = 306; LC = 357
- Foot dimensions [mm]: A = 125; B = 100; C = 50; CA = 120; H = 80 (−0.5); K = 10; K1 = 13; AA = 55; AB = 160; BB = 130; HA = 9; HD = 200
- Flange dimensions [mm] B5: R = 0; HB = 120; P = 200; M = 165; N = 130j6; S = 12; LA = 10; T = 3.5
- Flange dimensions [mm] B14A: R = 0; HB = 120; P = 120; M = 100; N = 80j6; S = M6; LE = 12; T = 3
- Flange dimensions [mm] B14B: R = 0; HB = 120; P = 160; M = 130; N = 110j6; S = M8; LE = 14; T = 3.5
- IP55
- 0,37 kW
- S1
- 935 1/min
- 230 V, 50 Hz ±5%
- 2,48 A
- End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
- Temperature protection: incl. 1 x PTC- PTC resistor
- terminal box layer at top
- housing of die cast aluminium
- Motor feet can be screwed on or unscrewed
- AC motors are suitable for both directions of rotation
- with operating capacitor nominal power at max 40° C and up to 1000 m above NN
- dynamically balanced with half paste spring inserted
- Vibration level "N"
- incl. EG installation declaration with disassembly, operation & maintenance instructions
- Due to the start-up and operating capacitor, the 230V motor has a stronger start-up torque.
- The start-up capacitor is switched off by a centrifugal force switch when the speed is reached.
- At low load, the temperature in the engine increases sharply and this can lead to failures.
- Therefore, it is recommended that single-phase motors should not be operated at a load below 25 % of the rated load.
IP55; 0,37 kW; S1; 2800/min; 230 V, 50 Hz ±67%; 2,73 A
End of shaft according to DIN/IEC Ø14 x 30 mm
Thermal class 155(F) with operating capacitor and start-up capacitor
Ma/Mn 2,30 rated power at max 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; vibration stage "N" i
nK EG installation declaration with disassembly, operation & maintenance instructions
End of shaft according to DIN/IEC Ø14 x 30 mm
Thermal class 155(F) with operating capacitor and start-up capacitor
Ma/Mn 2,30 rated power at max 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; vibration stage "N" i
nK EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
- Rated output P2 [kW]: 0.37
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Specified speed [min−1]: 2800
- Rated current [A]: 2.73
- Starting torque / rated torque: 2.30
- Frame size: 71
- Number of poles: 2
- Degree of protection: IP55
- Insulation class: F
- Ambient temperature: ≤ +40 °C
- Installation altitude up to [m]: 1000
- Vibration grade: N
- Mounting arrangement: Variants as selected
- Shaft end D × E [mm]: 14 × 30
- With run and start capacitors
- Dynamically balanced with half key
- Shaft end including key
- Removable feet; rotatable terminal box
- Rated output P2 [kW]: 0.37
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Rated speed [min−1]: 2800
- Rated current [A]: 3.0
- Rated torque [N·m]: 1.26
- Efficiency [%]: 64
- Power factor cos φ: 0.84
- Starting current / rated current: 2.7
- Starting torque / rated torque: 0.70
- Breakdown torque / rated torque: 1.80
- Moment of inertia J [kg·m²]: 0.00054
- Run capacitor [µF]: 12
- Frame size: 71
- Number of poles: 2
- Degree of protection: IP55
- Insulation class: F
- Motor weight, base design [kg]: 6.4
- Ambient temperature: -15…+40 °C
- Colour: RAL 5010
- Design standard: IEC 60034-1 / PN-EN 60034-1
- Mounting arrangement: Variants as selected
- Capacitor rated voltage [V]: 450
- Shaft end D × E [mm]: 14j6 × 30
- Bearings: 6203 2Z
- With run capacitor
- Further dimensions [mm]: D = 14j6; E = 30; F = 5h9; GA = 16; DW = M20; AC = 141; AD = 90; BL = 12; L = 245; LC = 283
- Foot dimensions [mm]: A = 112; B = 90; C = 45; CA = 88; H = 71 (−0.5); K = 7; K1 = 10; AA = 45; AB = 142; BB = 116; HA = 8; HD = 182
- Flange dimensions [mm] B5: R = 0; HB = 111; P = 160; M = 130; N = 110j6; S = 10; LA = 9; T = 3.5
- Flange dimensions [mm] B14A: R = 0; HB = 111; P = 105; M = 85; N = 70j6; S = M6; LE = 12; T = 2.5
- Flange dimensions [mm] B14B: R = 0; HB = 111; P = 140; M = 115; N = 95j6; S = M8; LE = 14; T = 3
IP55; 0,37 kW; S1; 2800/min; 230 V, 50 Hz ±67%; 2,73 A shaft end according to DIN/IEC Ø14 x 30 mm; thermal class 155(F) with operating capacitor nominal power at maximum 40° C and up to 1000 m via NN with inserted half paste spring; Vibration level "N" including EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
IP55; 0,25 kW; S1; 1370 1/min; 230 V, 50 Hz ±5%; 1,99 A
End of shaft according to DIN/IEC Ø14 x 30 mm Heat class 155(F)
with operating capacitor and starting capacitor Ma/Mn 2,50
Maximum rated power at maximum 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
End of shaft according to DIN/IEC Ø14 x 30 mm Heat class 155(F)
with operating capacitor and starting capacitor Ma/Mn 2,50
Maximum rated power at maximum 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
IP55; 0,25 kW; S1; 1370 1/min; 230 V, 50 Hz ±5%; 2,2 A
End of shaft according to DIN/IEC Ø14 x 30 mm Heat class 155(F)
with operating capacitor nominal power at max 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
End of shaft according to DIN/IEC Ø14 x 30 mm Heat class 155(F)
with operating capacitor nominal power at max 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
IP55; 0,55 kW; S1; 2800 1/min; 230 V, 50 Hz ±5%; 3,88 A
End of shaft according to DIN/IEC Ø14 x 30 mm Heat class 155(F)
with operating capacitor and starting capacitor Ma/Mn 2,50
Maximum rated power at maximum 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
End of shaft according to DIN/IEC Ø14 x 30 mm Heat class 155(F)
with operating capacitor and starting capacitor Ma/Mn 2,50
Maximum rated power at maximum 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
- Rated output P2 [kW]: 0.55
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Specified speed [min−1]: 2800
- Rated current [A]: 3.88
- Starting torque / rated torque: 2.50
- Frame size: 71
- Number of poles: 2
- Degree of protection: IP55
- Insulation class: F
- Ambient temperature: ≤ +40 °C
- Installation altitude up to [m]: 1000
- Vibration grade: N
- Mounting arrangement: Variants as selected
- Shaft end D × E [mm]: 14 × 30
- With run and start capacitors
- Dynamically balanced with half key
- Shaft end including key
- Removable feet; rotatable terminal box
- Rated output P2 [kW]: 0.55
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Rated speed [min−1]: 2780
- Rated current [A]: 3.6
- Rated torque [N·m]: 1.89
- Efficiency [%]: 70
- Power factor cos φ: 0.95
- Starting current / rated current: 3.2
- Starting torque / rated torque: 0.65
- Breakdown torque / rated torque: 1.60
- Moment of inertia J [kg·m²]: 0.00069
- Run capacitor [µF]: 20
- Frame size: 71
- Number of poles: 2
- Degree of protection: IP55
- Insulation class: F
- Motor weight, base design [kg]: 7.4
- Ambient temperature: -15…+40 °C
- Colour: RAL 5010
- Design standard: IEC 60034-1 / PN-EN 60034-1
- Mounting arrangement: Variants as selected
- Capacitor rated voltage [V]: 450
- Shaft end D × E [mm]: 14j6 × 30
- Bearings: 6203 2Z
- With run capacitor
- Further dimensions [mm]: D = 14j6; E = 30; F = 5h9; GA = 16; DW = M20; AC = 141; AD = 90; BL = 12; L = 263; LC = 301
- Foot dimensions [mm]: A = 112; B = 90; C = 45; CA = 106; H = 71 (−0.5); K = 7; K1 = 10; AA = 45; AB = 142; BB = 116; HA = 8; HD = 182
- Flange dimensions [mm] B5: R = 0; HB = 111; P = 160; M = 130; N = 110j6; S = 10; LA = 9; T = 3.5
- Flange dimensions [mm] B14A: R = 0; HB = 111; P = 105; M = 85; N = 70j6; S = M6; LE = 12; T = 2.5
- Flange dimensions [mm] B14B: R = 0; HB = 111; P = 140; M = 115; N = 95j6; S = M8; LE = 14; T = 3
IP55; 0,55 kW; S1; 2800 1/min; 230 V, 50 Hz ±5%; 3,63 A
End of shaft according to DIN/IEC Ø14 x 30 mm Heat class 155(F)
with operating capacitor nominal power at max 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
End of shaft according to DIN/IEC Ø14 x 30 mm Heat class 155(F)
with operating capacitor nominal power at max 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
IP55; 0,37 kW; S1; 1370 1/min; 230 V, 50 Hz ±5%; 2,81 A
End of shaft according to DIN/IEC Ø14 x 30 mm Heat class 155(F)
with operating capacitor and starting capacitor Ma/Mn 2,50
Maximum rated power at maximum 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
End of shaft according to DIN/IEC Ø14 x 30 mm Heat class 155(F)
with operating capacitor and starting capacitor Ma/Mn 2,50
Maximum rated power at maximum 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
- Rated output P2 [kW]: 0.37
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Specified speed [min−1]: 1370
- Rated current [A]: 2.81
- Starting torque / rated torque: 2.50
- Frame size: 71
- Number of poles: 4
- Degree of protection: IP55
- Insulation class: F
- Ambient temperature: ≤ +40 °C
- Installation altitude up to [m]: 1000
- Vibration grade: N
- Mounting arrangement: Variants as selected
- Shaft end D × E [mm]: 14 × 30
- With run and start capacitors
- Dynamically balanced with half key
- Shaft end including key
- Removable feet; rotatable terminal box
- Rated output P2 [kW]: 0.37
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Rated speed [min−1]: 1320
- Rated current [A]: 3.2
- Rated torque [N·m]: 2.68
- Efficiency [%]: 59
- Power factor cos φ: 0.88
- Starting current / rated current: 2.1
- Starting torque / rated torque: 0.80
- Breakdown torque / rated torque: 1.60
- Moment of inertia J [kg·m²]: 0.00101
- Run capacitor [µF]: 16
- Frame size: 71
- Number of poles: 4
- Degree of protection: IP55
- Insulation class: F
- Motor weight, base design [kg]: 7.4
- Ambient temperature: -15…+40 °C
- Colour: RAL 5010
- Design standard: IEC 60034-1 / PN-EN 60034-1
- Mounting arrangement: Variants as selected
- Capacitor rated voltage [V]: 450
- Shaft end D × E [mm]: 14j6 × 30
- Bearings: 6203 2Z
- With run capacitor
- Further dimensions [mm]: D = 14j6; E = 30; F = 5h9; GA = 16; DW = M20; AC = 141; AD = 90; BL = 12; L = 263; LC = 301
- Foot dimensions [mm]: A = 112; B = 90; C = 45; CA = 106; H = 71 (−0.5); K = 7; K1 = 10; AA = 45; AB = 142; BB = 116; HA = 8; HD = 182
- Flange dimensions [mm] B5: R = 0; HB = 111; P = 160; M = 130; N = 110j6; S = 10; LA = 9; T = 3.5
- Flange dimensions [mm] B14A: R = 0; HB = 111; P = 105; M = 85; N = 70j6; S = M6; LE = 12; T = 2.5
- Flange dimensions [mm] B14B: R = 0; HB = 111; P = 140; M = 115; N = 95j6; S = M8; LE = 14; T = 3
IP55; 0,37 kW; S1; 1370 1/min; 230 V, 50 Hz ±5%; 2,95 A
End of shaft according to DIN/IEC Ø14 x 30 mm Heat class 155(F)
with operating capacitor nominal power at max 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
End of shaft according to DIN/IEC Ø14 x 30 mm Heat class 155(F)
with operating capacitor nominal power at max 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
IP55; 0,75 kW; S1; 2800 1/min; 230 V, 50 Hz ±5%; 5,15 A
End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
with operating capacitor and starting capacitor Ma/Mn 2,50
Maximum rated power at maximum 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
with operating capacitor and starting capacitor Ma/Mn 2,50
Maximum rated power at maximum 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
- Rated output P2 [kW]: 0.75
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Specified speed [min−1]: 2800
- Rated current [A]: 5.15
- Starting torque / rated torque: 2.50
- Frame size: 80
- Number of poles: 2
- Degree of protection: IP55
- Insulation class: F
- Ambient temperature: ≤ +40 °C
- Installation altitude up to [m]: 1000
- Vibration grade: N
- Mounting arrangement: Variants as selected
- Shaft end D × E [mm]: 19 × 40
- With run and start capacitors
- Dynamically balanced with half key
- Shaft end including key
- Removable feet; rotatable terminal box
- Rated output P2 [kW]: 0.75
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Rated speed [min−1]: 2800
- Rated current [A]: 5.0
- Rated torque [N·m]: 2.56
- Efficiency [%]: 70
- Power factor cos φ: 0.94
- Starting current / rated current: 3.4
- Starting torque / rated torque: 0.65
- Breakdown torque / rated torque: 1.9
- Moment of inertia J [kg·m²]: 0.00111
- Run capacitor [µF]: 25
- Frame size: 80
- Number of poles: 2
- Degree of protection: IP55
- Insulation class: F
- Motor weight, base design [kg]: 9.7
- Ambient temperature: -15…+40 °C
- Colour: RAL 5010
- Design standard: IEC 60034-1 / PN-EN 60034-1
- Mounting arrangement: Variants as selected
- Capacitor rated voltage [V]: 450
- Shaft end D × E [mm]: 19j6 × 40
- Bearings: 6204 2Z
- With run capacitor
- Further dimensions [mm]: D = 19j6; E = 40; F = 6h9; GA = 21.5; DW = M20; AC = 157; AD = 95; BL = 15; L = 278; LC = 329
- Foot dimensions [mm]: A = 125; B = 100; C = 50; CA = 98; H = 80 (−0.5); K = 10; K1 = 13; AA = 55; AB = 160; BB = 130; HA = 9; HD = 200
- Flange dimensions [mm] B5: R = 0; HB = 120; P = 200; M = 165; N = 130j6; S = 12; LA = 10; T = 3.5
- Flange dimensions [mm] B14A: R = 0; HB = 120; P = 120; M = 100; N = 80j6; S = M6; LE = 12; T = 3
- Flange dimensions [mm] B14B: R = 0; HB = 120; P = 160; M = 130; N = 110j6; S = M8; LE = 14; T = 3.5
IP55; 0,75 kW; S1; 2800 1/min; 230 V, 50 Hz ±5%; 5,15 A
End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
with operating capacitor nominal power at max 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
with operating capacitor nominal power at max 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
- Rated output P2 [kW]: 0.55
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Specified speed [min−1]: 1400
- Rated current [A]: 4.00
- Starting torque / rated torque: 2.50
- Frame size: 80
- Number of poles: 4
- Degree of protection: IP55
- Insulation class: F
- Ambient temperature: ≤ +40 °C
- Installation altitude up to [m]: 1000
- Vibration grade: N
- Mounting arrangement: Variants as selected
- Shaft end D × E [mm]: 19 × 40
- With run and start capacitors
- Dynamically balanced with half key
- Shaft end including key
- Removable feet; rotatable terminal box
IP55; 0,55 kW; S1; 1400 1/min; 230 V, 50 Hz ±5%; 4,00 A
End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
with operating capacitor and starting capacitor Ma/Mn 2,50
Maximum rated power at maximum 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
with operating capacitor and starting capacitor Ma/Mn 2,50
Maximum rated power at maximum 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
- Rated output P2 [kW]: 0.55
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Rated speed [min−1]: 1360
- Rated current [A]: 3.9
- Rated torque [N·m]: 3.86
- Efficiency [%]: 68
- Power factor cos φ: 0.91
- Starting current / rated current: 2.6
- Starting torque / rated torque: 0.60
- Breakdown torque / rated torque: 1.6
- Moment of inertia J [kg·m²]: 0.00208
- Run capacitor [µF]: 20
- Frame size: 80
- Number of poles: 4
- Degree of protection: IP55
- Insulation class: F
- Motor weight, base design [kg]: 9.5
- Ambient temperature: -15…+40 °C
- Colour: RAL 5010
- Design standard: IEC 60034-1 / PN-EN 60034-1
- Mounting arrangement: Variants as selected
- Capacitor rated voltage [V]: 450
- Shaft end D × E [mm]: 19j6 × 40
- Bearings: 6204 2Z
- With run capacitor
- Further dimensions [mm]: D = 19j6; E = 40; F = 6h9; GA = 21.5; DW = M20; AC = 157; AD = 95; BL = 15; L = 278; LC = 329
- Foot dimensions [mm]: A = 125; B = 100; C = 50; CA = 98; H = 80 (−0.5); K = 10; K1 = 13; AA = 55; AB = 160; BB = 130; HA = 9; HD = 200
- Flange dimensions [mm] B5: R = 0; HB = 120; P = 200; M = 165; N = 130j6; S = 12; LA = 10; T = 3.5
- Flange dimensions [mm] B14A: R = 0; HB = 120; P = 120; M = 100; N = 80j6; S = M6; LE = 12; T = 3
- Flange dimensions [mm] B14B: R = 0; HB = 120; P = 160; M = 130; N = 110j6; S = M8; LE = 14; T = 3.5
IP55; 0,55 kW; S1; 1400 1/min; 230 V, 50 Hz ±5%; 4,25 A
End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
with operating capacitor nominal power at max 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
with operating capacitor nominal power at max 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
- Rated output P2 [kW]: 0.37
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Specified speed [min−1]: 930
- Rated current [A]: 2.48
- Frame size: 80
- Number of poles: 6
- Degree of protection: IP55
- Insulation class: F
- Ambient temperature: ≤ +40 °C
- Installation altitude up to [m]: 1000
- Vibration grade: N
- Mounting arrangement: Variants as selected
- Shaft end D × E [mm]: 19 × 40
- With run capacitor
- Dynamically balanced with half key
- Shaft end including key
- Removable feet; rotatable terminal box
IP55; 1,1 kW; S1; 2800 1/min; 230 V, 50 Hz ±5%; 7,02 A
End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
with operating capacitor nominal power at max 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
with operating capacitor nominal power at max 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
IP55; 1,1 kW; S1; 2800 1/min; 230 V, 50 Hz ±5%; 7,02 A
End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
with operating capacitor and starting capacitor Ma/Mn 2,50
Maximum rated power at maximum 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
with operating capacitor and starting capacitor Ma/Mn 2,50
Maximum rated power at maximum 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
- Rated output P2 [kW]: 1.1
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Specified speed [min−1]: 2800
- Rated current [A]: 7.02
- Starting torque / rated torque: 2.50
- Frame size: 80
- Number of poles: 2
- Degree of protection: IP55
- Insulation class: F
- Ambient temperature: ≤ +40 °C
- Installation altitude up to [m]: 1000
- Vibration grade: N
- Mounting arrangement: Variants as selected
- Shaft end D × E [mm]: 19 × 40
- With run and start capacitors
- Dynamically balanced with half key
- Shaft end including key
- Removable feet; rotatable terminal box
- Rated output P2 [kW]: 0.75
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Specified speed [min−1]: 1400
- Rated current [A]: 5.22
- Starting torque / rated torque: 2.50
- Frame size: 80
- Number of poles: 4
- Degree of protection: IP55
- Insulation class: F
- Ambient temperature: ≤ +40 °C
- Installation altitude up to [m]: 1000
- Vibration grade: N
- Mounting arrangement: Variants as selected
- Shaft end D × E [mm]: 19 × 40
- With run and start capacitors
- Dynamically balanced with half key
- Shaft end including key
- Removable feet; rotatable terminal box
IP55; 0,75 kW; S1; 1400 1/min; 230 V, 50 Hz ±5%; 5,22 A
End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
with operating capacitor and starting capacitor Ma/Mn 2,50
Maximum rated power at maximum 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
with operating capacitor and starting capacitor Ma/Mn 2,50
Maximum rated power at maximum 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
- Rated output P2 [kW]: 0.75
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Rated speed [min−1]: 1340
- Rated current [A]: 5.6
- Rated torque [N·m]: 5.35
- Efficiency [%]: 65
- Power factor cos φ: 0.90
- Starting current / rated current: 2.5
- Starting torque / rated torque: 0.65
- Breakdown torque / rated torque: 1.5
- Moment of inertia J [kg·m²]: 0.00265
- Run capacitor [µF]: 25
- Frame size: 80
- Number of poles: 4
- Degree of protection: IP55
- Insulation class: F
- Motor weight, base design [kg]: 11.5
- Ambient temperature: -15…+40 °C
- Colour: RAL 5010
- Design standard: IEC 60034-1 / PN-EN 60034-1
- Mounting arrangement: Variants as selected
- Capacitor rated voltage [V]: 450
- Shaft end D × E [mm]: 19j6 × 40
- Bearings: 6204 2Z
- With run capacitor
- Further dimensions [mm]: D = 19j6; E = 40; F = 6h9; GA = 21.5; DW = M20; AC = 157; AD = 95; BL = 15; L = 306; LC = 357
- Foot dimensions [mm]: A = 125; B = 100; C = 50; CA = 120; H = 80 (−0.5); K = 10; K1 = 13; AA = 55; AB = 160; BB = 130; HA = 9; HD = 200
- Flange dimensions [mm] B5: R = 0; HB = 120; P = 200; M = 165; N = 130j6; S = 12; LA = 10; T = 3.5
- Flange dimensions [mm] B14A: R = 0; HB = 120; P = 120; M = 100; N = 80j6; S = M6; LE = 12; T = 3
- Flange dimensions [mm] B14B: R = 0; HB = 120; P = 160; M = 130; N = 110j6; S = M8; LE = 14; T = 3.5
IP55; 0,75 kW; S1; 1400 1/min; 230 V, 50 Hz ±5%; 5,45 A
End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
with operating capacitor nominal power at max 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
with operating capacitor nominal power at max 40° C and up to 1000 m above NN
dynamically balanced with half paste spring inserted; Vibration level "N"
incl. EG installation declaration with disassembly, operation & maintenance instructions
- Foot mounting: Removable feet (terminal box can be repositioned).
- Rated output P2 [kW]: 0.55
- Rated voltage [V]: 230
- Rated frequency [Hz]: 50
- Duty type: S1
- Specified speed [min−1]: 930
- Rated current [A]: 3.47
- Frame size: 80
- Number of poles: 6
- Degree of protection: IP55
- Insulation class: F
- Ambient temperature: ≤ +40 °C
- Installation altitude up to [m]: 1000
- Vibration grade: N
- Mounting arrangement: Variants as selected
- Shaft end D × E [mm]: 19 × 40
- With run capacitor
- Dynamically balanced with half key
- Shaft end including key
- Removable feet; rotatable terminal box
- IP55
- 0,18 kW
- S1
- 930 1/min
- 230 V, 50 Hz ±5%
- 1,34 A
- End of shaft according to DIN/IEC Ø14 x 30 mm Heat class 155(F)
- Temperature protection: incl. 1 x PTC- PTC resistor
- terminal box layer at top
- housing of die cast aluminium
- Motor feet can be screwed on or unscrewed
- AC motors are suitable for both directions of rotation
- with operating capacitor nominal power at max 40° C and up to 1000 m above NN
- dynamically balanced with half paste spring inserted
- Vibration level "N"
- incl. EG installation declaration with disassembly, operation & maintenance instructions
- Due to the start-up and operating capacitor, the 230V motor has a stronger start-up torque.
- The start-up capacitor is switched off by a centrifugal force switch when the speed is reached.
- At low load, the temperature in the engine increases sharply and this can lead to failures.
- Therefore, it is recommended that single-phase motors should not be operated at a load below 25 % of the rated load.
- IP55
- 0,25 kW
- S1
- 930 1/min
- 230 V, 50 Hz ±5%
- 1,86 A
- End of shaft according to DIN/IEC Ø14 x 30 mm Heat class 155(F)
- Temperature protection: incl. 1 x PTC- PTC resistor
- terminal box layer at top
- housing of die cast aluminium
- Motor feet can be screwed on or unscrewed
- AC motors are suitable for both directions of rotation
- with operating capacitor nominal power at max 40° C and up to 1000 m above NN
- dynamically balanced with half paste spring inserted
- Vibration level "N"
- incl. EG installation declaration with disassembly, operation & maintenance instructions
- Due to the start-up and operating capacitor, the 230V motor has a stronger start-up torque.
- The start-up capacitor is switched off by a centrifugal force switch when the speed is reached.
- At low load, the temperature in the engine increases sharply and this can lead to failures.
- Therefore, it is recommended that single-phase motors should not be operated at a load below 25 % of the rated load.
- IP55
- 0,55 kW
- S1
- 935 1/min
- 230 V, 50 Hz ±5%
- 3,47 A
- End of shaft according to DIN/IEC Ø19 x 40 mm Heat class 155(F)
- Temperature protection: incl. 1 x PTC- PTC resistor
- terminal box layer at top
- housing of die cast aluminium
- Motor feet can be screwed on or unscrewed
- AC motors are suitable for both directions of rotation
- with operating capacitor nominal power at max 40° C and up to 1000 m above NN
- dynamically balanced with half paste spring inserted
- Vibration level "N"
- incl. EG installation declaration with disassembly, operation & maintenance instructions
- Due to the start-up and operating capacitor, the 230V motor has a stronger start-up torque.
- The start-up capacitor is switched off by a centrifugal force switch when the speed is reached.
- At low load, the temperature in the engine increases sharply and this can lead to failures.
- Therefore, it is recommended that single-phase motors should not be operated at a load below 25 % of the rated load.
Items 1 - 38 of 38