MITSUBISHI
Items 1 - 20 of 58
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 4,6
- Rated Output Current LD (A): 4,2
- Rated Output Current ND (A): 3
- Rated Output Current HD (A): 1,5
- Rated Motor Capacity SLD (kW): 0,75
- Rated Motor Capacity LD (kW): 0,75
- Rated Motor Capacity ND (kW): 0,4
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 7,7
- Rated Output Current LD (A): 7
- Rated Output Current ND (A): 5
- Rated Output Current HD (A): 3
- Rated Motor Capacity SLD (kW): 1,5
- Rated Motor Capacity LD (kW): 1,5
- Rated Motor Capacity ND (kW): 0,75
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 10,5
- Rated Output Current LD (A): 9,6
- Rated Output Current ND (A): 8
- Rated Output Current HD (A): 5
- Rated Motor Capacity SLD (kW): 2,2
- Rated Motor Capacity LD (kW): 2,2
- Rated Motor Capacity ND (kW): 1,5
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 16,7
- Rated Output Current LD (A): 15,2
- Rated Output Current ND (A): 11
- Rated Output Current HD (A): 8
- Rated Motor Capacity SLD (kW): 3,7
- Rated Motor Capacity LD (kW): 3,7
- Rated Motor Capacity ND (kW): 2,2
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 25
- Rated Output Current LD (A): 23
- Rated Output Current ND (A): 17,5
- Rated Output Current HD (A): 11
- Rated Motor Capacity SLD (kW): 5,5
- Rated Motor Capacity LD (kW): 5,5
- Rated Motor Capacity ND (kW): 3,7
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 34
- Rated Output Current LD (A): 31
- Rated Output Current ND (A): 24
- Rated Output Current HD (A): 17,5
- Rated Motor Capacity SLD (kW): 7,5
- Rated Motor Capacity LD (kW): 7,5
- Rated Motor Capacity ND (kW): 5,5
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 49
- Rated Output Current LD (A): 45
- Rated Output Current ND (A): 33
- Rated Output Current HD (A): 24
- Rated Motor Capacity SLD (kW): 11
- Rated Motor Capacity LD (kW): 11
- Rated Motor Capacity ND (kW): 7,5
- Frequency inverters
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum nominal voltage (V): 200
- Min. allowed voltage (V): 170
- Maximum rated voltage (V): 240
- Maximum permissible voltage (V): 264
- Type of electricity: AC
- Phases: 3
- Rated output current SLD (A): 63
- Rated output current LD (A): 58
- Rated output current ND (A): 46
- Rated output current HD (A): 33
- Rated engine power SLD (kW): 15
- Rated engine power LD (kW): 15
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 77
- Rated Output Current LD (A): 70,5
- Rated Output Current ND (A): 61
- Rated Output Current HD (A): 46
- Rated Motor Capacity SLD (kW): 18,5
- Rated Motor Capacity LD (kW): 18,5
- Rated Motor Capacity ND (kW): 15
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 93
- Rated Output Current LD (A): 85
- Rated Output Current ND (A): 76
- Rated Output Current HD (A): 61
- Rated Motor Capacity SLD (kW): 22
- Rated Motor Capacity LD (kW): 22
- Rated Motor Capacity ND (kW): 18,5
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 125
- Rated Output Current LD (A): 114
- Rated Output Current ND (A): 90
- Rated Output Current HD (A): 76
- Rated Motor Capacity SLD (kW): 30
- Rated Motor Capacity LD (kW): 30
- Rated Motor Capacity ND (kW): 22
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 154
- Rated Output Current LD (A): 140
- Rated Output Current ND (A): 115
- Rated Output Current HD (A): 90
- Rated Motor Capacity SLD (kW): 37
- Rated Motor Capacity LD (kW): 37
- Rated Motor Capacity ND (kW): 30
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 187
- Rated Output Current LD (A): 170
- Rated Output Current ND (A): 145
- Rated Output Current HD (A): 115
- Rated Motor Capacity SLD (kW): 45
- Rated Motor Capacity LD (kW): 45
- Rated Motor Capacity ND (kW): 37
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 233
- Rated Output Current LD (A): 212
- Rated Output Current ND (A): 175
- Rated Output Current HD (A): 145
- Rated Motor Capacity SLD (kW): 55
- Rated Motor Capacity LD (kW): 55
- Rated Motor Capacity ND (kW): 45
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 316
- Rated Output Current LD (A): 288
- Rated Output Current ND (A): 215
- Rated Output Current HD (A): 175
- Rated Motor Capacity SLD (kW): 75
- Rated Motor Capacity LD (kW): 75
- Rated Motor Capacity ND (kW): 55
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 380
- Rated Output Current LD (A): 346
- Rated Output Current ND (A): 288
- Rated Output Current HD (A): 215
- Rated Motor Capacity LD (kW): 90
- Rated Motor Capacity ND (kW): 75
- Rated Motor Capacity HD (kW): 55
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 475
- Rated Output Current LD (A): 432
- Rated Output Current ND (A): 346
- Rated Output Current HD (A): 288
- Rated Motor Capacity SLD (kW): 132
- Rated Motor Capacity LD (kW): 110
- Rated Motor Capacity ND (kW): 90
- frequency inverter
- Series: FR-D800 SERIES
- Type: FR-D800 COMPACT INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 1,4
- Rated Output Current ND (A): 0,8
- Rated Motor Capacity SLD (kW): 0,20
- Rated Motor Capacity ND (kW): 0,1
- Control Method: Adv. magnetic flux vector PM sensorless vector control V/F control
- Motor Type: INDUCTION MOTOR
- Brake Chopper ED (%): 0
- frequency inverter
- Series: FR-D800 SERIES
- Type: FR-D800 COMPACT INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 1,4
- Rated Output Current ND (A): 0,8
- Rated Motor Capacity SLD (kW): 0,20
- Rated Motor Capacity ND (kW): 0,1
- Control Method: Adv. magnetic flux vector PM sensorless vector control V/F control
- Motor Type: INDUCTION MOTOR
- Brake Chopper ED (%): 0
- frequency inverter
- Series: FR-D800 SERIES
- Type: FR-D800 COMPACT INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 2,5
- Rated Output Current ND (A): 1,4
- Rated Motor Capacity SLD (kW): 0,40
- Rated Motor Capacity ND (kW): 0,2
- Control Method: Adv. magnetic flux vector PM sensorless vector control V/F control
- Motor Type: INDUCTION MOTOR
- Brake Chopper ED (%): 0
Items 1 - 20 of 58