MITSUBISHI
- frequency inverter
- Series: FR-F800 SERIES
- Type: FR-F800 PUMP AND FAN
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 233
- Rated Output Current LD (A): 212
- Rated Motor Capacity SLD (kW): 55
- Rated Motor Capacity LD (kW): 55
- Control Method: MAGNETIC FLUX VECTOR CONTROL PM SENSORLESS VECTOR CONTROL SOFT-PWM/HIGH FREQUENCY PWM V/F CONTROL
- Motor Type: INDUCTION MOTOR, PM MOTOR
- Integrated EMC Filter: YES (OFF ON INITIAL SETTINGS)
- frequency inverter
- Series: FR-A800 PLUS SERIES
- Type: FR-A800-R2R (FOR ROLL TO ROLL)
- Minimum Rated Voltage (V): 380
- Min. Permissible Voltage (V): 323
- Maximum Rated Voltage (V): 500
- Max. Permissible Voltage (V): 550
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 180
- Rated Output Current LD (A): 144
- Rated Output Current ND (A): 110
- Rated Output Current HD (A): 86
- Rated Motor Capacity ND (kW): 55
- Rated Motor Capacity HD (kW): 45
- Control Method: VECTOR CONTROL (WITH FR-A8AP) V/F CONTROL SOFT-PWM/HIGH FREQUENCY PWM REAL SENSORLESS VECTOR CONTROL PM SENSORLESS VECTOR CONTROL MAGNETIC FLUX VECTOR CONTROL
- frequency inverter
- Series: FR-A800 PLUS SERIES
- Type: FR-A800-R2R (FOR ROLL TO ROLL)
- Minimum Rated Voltage (V): 380
- Min. Permissible Voltage (V): 323
- Maximum Rated Voltage (V): 500
- Max. Permissible Voltage (V): 550
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 216
- Rated Output Current LD (A): 180
- Rated Output Current ND (A): 144
- Rated Output Current HD (A): 110
- Rated Motor Capacity ND (kW): 75
- Rated Motor Capacity HD (kW): 55
- Control Method: VECTOR CONTROL (WITH FR-A8AP) V/F CONTROL SOFT-PWM/HIGH FREQUENCY PWM REAL SENSORLESS VECTOR CONTROL PM SENSORLESS VECTOR CONTROL MAGNETIC FLUX VECTOR CONTROL
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 525/600
- Min. Permissible Voltage (V): 472/540
- Maximum Rated Voltage (V): 600/690
- Max. Permissible Voltage (V): 660/759
- Current Type: AC
- Phases: 3
- Rated Output Current ND (A): 66
- Rated Motor Capacity ND (kW): 55
- Control Method: SOFT-PWM/HIGH FRQ PWM/VECTOR
- Motor Type: INDUCTION MOTOR, PM MOTOR
- Integrated EMC Filter: YES
- Safe Torque Off (STO): YES
- Regenerative (4Q): NO
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 525/600
- Min. Permissible Voltage (V): 472/540
- Maximum Rated Voltage (V): 600/690
- Max. Permissible Voltage (V): 660/759
- Current Type: AC
- Phases: 3
- Rated Output Current ND (A): 66
- Rated Motor Capacity ND (kW): 55
- Control Method: SOFT-PWM/HIGH FRQ PWM/VECTOR
- Motor Type: INDUCTION MOTOR, PM MOTOR
- Integrated EMC Filter: YES
- Safe Torque Off (STO): YES
- Regenerative (4Q): YES
- frequency inverter
- Series: FR-A800 PLUS SERIES
- Type: FR-A800-R2R (FOR ROLL TO ROLL)
- Minimum Rated Voltage (V): 380
- Min. Permissible Voltage (V): 323
- Maximum Rated Voltage (V): 500
- Max. Permissible Voltage (V): 550
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 547
- Rated Output Current LD (A): 481
- Rated Output Current ND (A): 432
- Rated Output Current HD (A): 361
- Rated Motor Capacity ND (kW): 220
- Rated Motor Capacity HD (kW): 185
- Control Method: VECTOR CONTROL (WITH FR-A8AP) V/F CONTROL SOFT-PWM/HIGH FREQUENCY PWM REAL SENSORLESS VECTOR CONTROL PM SENSORLESS VECTOR CONTROL MAGNETIC FLUX VECTOR CONTROL
- frequency inverter
- Series: FR-A800 PLUS SERIES
- Type: FR-A800-R2R (FOR ROLL TO ROLL)
- Minimum Rated Voltage (V): 380
- Min. Permissible Voltage (V): 323
- Maximum Rated Voltage (V): 500
- Max. Permissible Voltage (V): 550
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 610
- Rated Output Current LD (A): 547
- Rated Output Current ND (A): 481
- Rated Output Current HD (A): 432
- Rated Motor Capacity ND (kW): 250
- Rated Motor Capacity HD (kW): 220
- Control Method: VECTOR CONTROL (WITH FR-A8AP) V/F CONTROL SOFT-PWM/HIGH FREQUENCY PWM REAL SENSORLESS VECTOR CONTROL PM SENSORLESS VECTOR CONTROL MAGNETIC FLUX VECTOR CONTROL