MITSUBISHI
Items 21 - 40 of 60
- frequency inverter
- Series: FR-E800 SERIES
- Type: FR-E800-ETH INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 1
- Rated Output Current ND (A): 8
- Rated Motor Capacity ND (kW): 1,5
- Control Method: V/F CONTROL REAL SENSORLESS VECTOR CONTROL PM SENSORLESS VECTOR CONTROL MAGNETIC FLUX VECTOR CONTROL
- Motor Type: INDUCTION MOTOR, PM MOTOR
- Brake Chopper ED (%): 100
- Integrated EMC Filter: NO
- Safe Torque Off (STO): YES
- frequency inverter
- Series: FR-E800 SERIES
- Type: FR-E800-ETH INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 1
- Rated Output Current ND (A): 8
- Rated Motor Capacity ND (kW): 1,5
- Control Method: V/F CONTROL REAL SENSORLESS VECTOR CONTROL PM SENSORLESS VECTOR CONTROL MAGNETIC FLUX VECTOR CONTROL
- Motor Type: INDUCTION MOTOR, PM MOTOR
- Brake Chopper ED (%): 100
- Integrated EMC Filter: NO
- Safe Torque Off (STO): YES
- frequency inverter
- Series: FR-E800 SERIES
- Type: FR-E800-ETH INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 1
- Rated Output Current ND (A): 8
- Rated Motor Capacity ND (kW): 1,5
- Control Method: V/F CONTROL REAL SENSORLESS VECTOR CONTROL PM SENSORLESS VECTOR CONTROL MAGNETIC FLUX VECTOR CONTROL
- Motor Type: INDUCTION MOTOR, PM MOTOR
- Brake Chopper ED (%): 100
- Integrated EMC Filter: NO
- Safe Torque Off (STO): YES
- frequency inverter
- Series: FR-E800 SERIES
- Type: FR-E800 RS485 INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 1
- Rated Output Current ND (A): 8
- Rated Motor Capacity ND (kW): 1,5
- Control Method: V/F CONTROL REAL SENSORLESS VECTOR CONTROL PM SENSORLESS VECTOR CONTROL MAGNETIC FLUX VECTOR CONTROL
- Motor Type: INDUCTION MOTOR, PM MOTOR
- Brake Chopper ED (%): 100
- Integrated EMC Filter: NO
- Safe Torque Off (STO): YES
- frequency inverter
- Series: FR-E800 SERIES
- Type: FR-E800 RS485 INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current LD (A): 6
- Rated Output Current ND (A): 5
- Rated Motor Capacity LD (kW): 1,5
- Rated Motor Capacity ND (kW): 0,75
- Control Method: V/F CONTROL REAL SENSORLESS VECTOR CONTROL PM SENSORLESS VECTOR CONTROL MAGNETIC FLUX VECTOR CONTROL
- Motor Type: INDUCTION MOTOR, PM MOTOR
- Brake Chopper ED (%): 30
- frequency inverter
- Series: FR-D800 SERIES
- Type: FR-D800 COMPACT INVERTER
- Minimum Rated Voltage (V): 380
- Min. Permissible Voltage (V): 323
- Maximum Rated Voltage (V): 480
- Max. Permissible Voltage (V): 528
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 5
- Rated Output Current ND (A): 3,7
- Rated Motor Capacity SLD (kW): 2,20
- Rated Motor Capacity ND (kW): 1,5
- Control Method: Adv. magnetic flux vector PM sensorless vector control V/F control
- Motor Type: INDUCTION MOTOR
- Brake Chopper ED (%): 100
- frequency inverter
- Series: FR-D800 SERIES
- Type: FR-D800 COMPACT INVERTER
- Minimum Rated Voltage (V): 380
- Min. Permissible Voltage (V): 323
- Maximum Rated Voltage (V): 480
- Max. Permissible Voltage (V): 528
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 5
- Rated Output Current ND (A): 3,7
- Rated Motor Capacity SLD (kW): 2,20
- Rated Motor Capacity ND (kW): 1,5
- Control Method: Adv. magnetic flux vector PM sensorless vector control V/F control
- Motor Type: INDUCTION MOTOR
- Brake Chopper ED (%): 100
- frequency inverter
- Series: FR-D800 SERIES
- Type: FR-D800 COMPACT INVERTER
- Minimum Rated Voltage (V): 380
- Min. Permissible Voltage (V): 323
- Maximum Rated Voltage (V): 480
- Max. Permissible Voltage (V): 528
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 3,7
- Rated Output Current ND (A): 2,2
- Rated Motor Capacity SLD (kW): 1,50
- Rated Motor Capacity ND (kW): 0,75
- Control Method: Adv. magnetic flux vector PM sensorless vector control V/F control
- Motor Type: INDUCTION MOTOR
- Brake Chopper ED (%): 100
- frequency inverter
- Series: FR-D800 SERIES
- Type: FR-D800 COMPACT INVERTER
- Minimum Rated Voltage (V): 380
- Min. Permissible Voltage (V): 323
- Maximum Rated Voltage (V): 480
- Max. Permissible Voltage (V): 528
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 3,7
- Rated Output Current ND (A): 2,2
- Rated Motor Capacity SLD (kW): 1,50
- Rated Motor Capacity ND (kW): 0,75
- Control Method: Adv. magnetic flux vector PM sensorless vector control V/F control
- Motor Type: INDUCTION MOTOR
- Brake Chopper ED (%): 100
- frequency inverter
- Series: FR-D800 SERIES
- Type: FR-D800 COMPACT INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 1
- Rated Output Current ND (A): 7,0
- Rated Motor Capacity ND (kW): 1,5
- Control Method: Adv. magnetic flux vector PM sensorless vector control V/F control
- Motor Type: INDUCTION MOTOR
- Brake Chopper ED (%): 100
- Integrated EMC Filter: NO
- Safe Torque Off (STO): YES
- frequency inverter
- Series: FR-D800 SERIES
- Type: FR-D800 COMPACT INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 1
- Rated Output Current ND (A): 7,0
- Rated Motor Capacity ND (kW): 1,5
- Control Method: Adv. magnetic flux vector PM sensorless vector control V/F control
- Motor Type: INDUCTION MOTOR
- Brake Chopper ED (%): 100
- Integrated EMC Filter: NO
- Safe Torque Off (STO): YES
- frequency inverter
- Series: FR-D800 SERIES
- Type: FR-D800 COMPACT INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 10
- Rated Output Current ND (A): 7,0
- Rated Motor Capacity SLD (kW): 2,20
- Rated Motor Capacity ND (kW): 1,5
- Control Method: Adv. magnetic flux vector PM sensorless vector control V/F control
- Motor Type: INDUCTION MOTOR
- Brake Chopper ED (%): 100
- frequency inverter
- Series: FR-D800 SERIES
- Type: FR-D800 COMPACT INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 10
- Rated Output Current ND (A): 7,0
- Rated Motor Capacity SLD (kW): 2,20
- Rated Motor Capacity ND (kW): 1,5
- Control Method: Adv. magnetic flux vector PM sensorless vector control V/F control
- Motor Type: INDUCTION MOTOR
- Brake Chopper ED (%): 100
- frequency inverter
- Series: FR-CS80 SERIES
- Type: FR-CS84 COMPACT INVERTER
- Minimum Rated Voltage (V): 380
- Min. Permissible Voltage (V): 323
- Maximum Rated Voltage (V): 480
- Max. Permissible Voltage (V): 550
- Current Type: AC
- Phases: 3
- Rated Output Current ND (A): 3,6
- Rated Motor Capacity ND (kW): 1,5
- Control Method: ADVANCED MAGN. FLUX VEC. CTRL
- Motor Type: INDUCTION MOTOR
- Integrated EMC Filter: NO
- Safe Torque Off (STO): NO
- Regenerative (4Q): NO
- frequency inverter
- Series: FR-CS80 SERIES
- Type: FR-CS82 COMPACT INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 1
- Rated Output Current ND (A): 7
- Rated Motor Capacity ND (kW): 1,5
- Control Method: ADVANCED MAGN. FLUX VEC. CTRL
- Motor Type: INDUCTION MOTOR
- Integrated EMC Filter: NO
- Safe Torque Off (STO): NO
- Regenerative (4Q): NO
- frequency inverter
- Series: FR-A/F800 SERIES
- Type: BASE UNIT FOR INV A842/F842
- Minimum Rated Voltage (V): 430
- Min. Permissible Voltage (V): 430
- Maximum Rated Voltage (V): 780
- Max. Permissible Voltage (V): 780
- Current Type: DC
- Phases: 1
- Rated Output Current SLD (A): 962
- Rated Output Current LD (A): 866
- Rated Output Current ND (A): 770
- Rated Output Current HD (A): 683
- Rated Motor Capacity SLD (kW): 500
- Rated Motor Capacity LD (kW): 450
- Rated Motor Capacity ND (kW): 400
- frequency inverter
- Series: FR-A/F800 SERIES
- Type: BASE UNIT FOR INV A842/F842
- Minimum Rated Voltage (V): 430
- Min. Permissible Voltage (V): 430
- Maximum Rated Voltage (V): 780
- Max. Permissible Voltage (V): 780
- Current Type: DC
- Phases: 1
- Rated Output Current SLD (A): 866
- Rated Output Current LD (A): 770
- Rated Output Current ND (A): 683
- Rated Output Current HD (A): 610
- Rated Motor Capacity SLD (kW): 450
- Rated Motor Capacity LD (kW): 400
- Rated Motor Capacity ND (kW): 355
- frequency inverter
- Series: FR-A/F800 SERIES
- Type: BASE UNIT FOR INV A842/F842
- Minimum Rated Voltage (V): 430
- Min. Permissible Voltage (V): 430
- Maximum Rated Voltage (V): 780
- Max. Permissible Voltage (V): 780
- Current Type: DC
- Phases: 1
- Rated Output Current SLD (A): 770
- Rated Output Current LD (A): 683
- Rated Output Current ND (A): 610
- Rated Output Current HD (A): 547
- Rated Motor Capacity SLD (kW): 400
- Rated Motor Capacity LD (kW): 355
- Rated Motor Capacity ND (kW): 315
- frequency inverter
- Series: FR-A/F800 SERIES
- Type: BASE UNIT FOR INV A840/F840
- Minimum Rated Voltage (V): 380
- Min. Permissible Voltage (V): 323
- Maximum Rated Voltage (V): 500
- Max. Permissible Voltage (V): 550
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 683
- Rated Output Current LD (A): 610
- Rated Output Current ND (A): 547
- Rated Output Current HD (A): 481
- Rated Motor Capacity SLD (kW): 355
- Rated Motor Capacity LD (kW): 315
- Rated Motor Capacity ND (kW): 280
- frequency inverter
- Series: FR-A800 PLUS SERIES
- Type: FR-A800-LC (LIQUID COOLED)
- Minimum Rated Voltage (V): 525/600
- Min. Permissible Voltage (V): 472/540
- Maximum Rated Voltage (V): 600/690
- Max. Permissible Voltage (V): 660/759
- Current Type: AC
- Phases: 3
- Rated Output Current ND (A): 405
- Rated Motor Capacity ND (kW): 355
- Control Method: SOFT-PWM/HIGH FRQ PWM/VECTOR
- Motor Type: INDUCTION MOTOR
- Integrated EMC Filter: YES
- Safe Torque Off (STO): YES
- Regenerative (4Q): NO
Items 21 - 40 of 60