MITSUBISHI
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A741 INVERTER
- Minimum Rated Voltage (V): 380
- Min. Permissible Voltage (V): 323
- Maximum Rated Voltage (V): 480
- Max. Permissible Voltage (V): 528
- Current Type: AC
- Phases: 3
- Rated Output Current ND (A): 38
- Rated Motor Capacity ND (kW): 18,5
- Control Method: VECTOR CONTROL
- Motor Type: INDUCTION MOTOR
- Brake Chopper ED (%): 30
- Integrated EMC Filter: YES
- Safe Torque Off (STO): NO
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A741 INVERTER
- Minimum Rated Voltage (V): 380
- Min. Permissible Voltage (V): 323
- Maximum Rated Voltage (V): 480
- Max. Permissible Voltage (V): 528
- Current Type: AC
- Phases: 3
- Rated Output Current ND (A): 44
- Rated Motor Capacity ND (kW): 22
- Control Method: VECTOR CONTROL
- Motor Type: INDUCTION MOTOR
- Brake Chopper ED (%): 30
- Integrated EMC Filter: YES
- Safe Torque Off (STO): NO
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 4,6
- Rated Output Current LD (A): 4,2
- Rated Output Current ND (A): 3
- Rated Output Current HD (A): 1,5
- Rated Motor Capacity SLD (kW): 0,75
- Rated Motor Capacity LD (kW): 0,75
- Rated Motor Capacity ND (kW): 0,4
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 7,7
- Rated Output Current LD (A): 7
- Rated Output Current ND (A): 5
- Rated Output Current HD (A): 3
- Rated Motor Capacity SLD (kW): 1,5
- Rated Motor Capacity LD (kW): 1,5
- Rated Motor Capacity ND (kW): 0,75
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 77
- Rated Output Current LD (A): 70,5
- Rated Output Current ND (A): 61
- Rated Output Current HD (A): 46
- Rated Motor Capacity SLD (kW): 18,5
- Rated Motor Capacity LD (kW): 18,5
- Rated Motor Capacity ND (kW): 15
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 93
- Rated Output Current LD (A): 85
- Rated Output Current ND (A): 76
- Rated Output Current HD (A): 61
- Rated Motor Capacity SLD (kW): 22
- Rated Motor Capacity LD (kW): 22
- Rated Motor Capacity ND (kW): 18,5
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 125
- Rated Output Current LD (A): 114
- Rated Output Current ND (A): 90
- Rated Output Current HD (A): 76
- Rated Motor Capacity SLD (kW): 30
- Rated Motor Capacity LD (kW): 30
- Rated Motor Capacity ND (kW): 22
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 200
- Min. Permissible Voltage (V): 170
- Maximum Rated Voltage (V): 240
- Max. Permissible Voltage (V): 264
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 154
- Rated Output Current LD (A): 140
- Rated Output Current ND (A): 115
- Rated Output Current HD (A): 90
- Rated Motor Capacity SLD (kW): 37
- Rated Motor Capacity LD (kW): 37
- Rated Motor Capacity ND (kW): 30
- frequency inverter
- Series: FR-A SERIES
- Type: FR-A800-E INVERTER
- Minimum Rated Voltage (V): 380
- Min. Permissible Voltage (V): 323
- Maximum Rated Voltage (V): 500
- Max. Permissible Voltage (V): 550
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 2,3
- Rated Output Current LD (A): 2,1
- Rated Output Current ND (A): 1,5
- Rated Output Current HD (A): 0,8
- Rated Motor Capacity SLD (kW): 0,75
- Rated Motor Capacity LD (kW): 0,75
- Rated Motor Capacity ND (kW): 0,4
- frequency inverter
- Series: FR-A800 PLUS SERIES
- Type: FR-A800-CRN (FOR CRANES)
- Minimum Rated Voltage (V): 380
- Min. Permissible Voltage (V): 323
- Maximum Rated Voltage (V): 500
- Max. Permissible Voltage (V): 550
- Current Type: AC
- Phases: 3
- Rated Output Current SLD (A): 2,3
- Rated Output Current LD (A): 2,1
- Rated Output Current ND (A): 1,5
- Rated Output Current HD (A): 0,8
- Rated Motor Capacity ND (kW): 0,4
- Rated Motor Capacity HD (kW): 0,2
- Control Method: VECTOR CONTROL (WITH FR-A8AP) V/F CONTROL SOFT-PWM/HIGH FREQUENCY PWM REAL SENSORLESS VECTOR CONTROL PM SENSORLESS VECTOR CONTROL MAGNETIC FLUX VECTOR CONTROL