TOSHIBA
Items 1 - 10 of 10
incl. SPS - Industry 4.0/IoT Ready with real-time clock
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type...90 kW (HD) in IP55
- EMV filter class: Category C2 (EN61800-3) or A (EN55011)...37 kW (HD)
- Ambient temperature -10... +60°C (storage temperature -25... +70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
3-ph 27A for EMV 4803AC/048A for VFS15-4110; 4150 362 - 180 - 55 mm Rated voltage: 480 V Rated current: 48A 3ph leakage current; 0,2mA nom/14mA ma. Limits C1 25m/ C2 50m (@6kHz) IP20
- Engine power: 7,50/11,00 kW (constant/quadratic torque)
- Output current: 17,00/23,00 A (constant/quadratic torque)
- Dimensions: HxBxT 150x170x220 mm
- Receipt: 400 V3AC (323…550V), 50/60 Hz
- Output: 0-Uin (V3AC); 0-500 Hz
- Overload 60s: 150/120 % (constant/quadratic torque)
- Protection type: IP20/JEM1030
- EMV filter class: A (EN55011) or category C2 (EN61800-3)
- Ambient temperature: -10 to +40(60)°C
- Clock frequency: 2.0-16.0 kHz
- Digital display: 4-digit (programmable)
• SPS functions Processes with up to 14 links in function plan logic
• Suitable for permanent magnet-excited motors
• Stable torque in generator operation
• Improved braking performance; Extended functionality for external brakes
• with PM motor drive for more effective energy saving
• Many interfaces available
• with PTC input
• Immediate start of work after engine connection
• Premium functions: Extended SPS; PM engines; servo-lock; STO function
- Engine power: 11,00/15,00 kW (constant/quadratic torque)
- Output current: 27,70/31,00 A (constant/quadratic torque)
- Dimensions: HxBxT 180x190x310 mm
- Receipt: 400 V3AC (323…550V), 50/60 Hz
- Output: 0-Uin (V3AC); 0-500 Hz
- Overload 60s: 150/120 % (constant/quadratic torque)
- Protection type: IP20/JEM1030
- EMV filter class: A (EN55011) or category C2 (EN61800-3)
- Ambient temperature: -10 to +40(60)°C
- Clock frequency: 2.0-16.0 kHz
- Digital display: 4-digit (programmable)
• SPS functions Processes with up to 14 links in function plan logic
• Suitable for permanent magnet-excited motors
• Stable torque in generator operation
• Improved braking performance; Extended functionality for external brakes
• with PM motor drive for more effective energy saving
• Many interfaces available
• with PTC input
• Immediate start of work after engine connection
• Premium functions: Extended SPS; PM engines; servo-lock; STO function
- Engine power: 7,50/11,50 kW (constant/quadratic torque)
- Output current: 33,0/48,4 A (constant/quadratic torque)
- Dimensions: HxBxT 220x150x170 mm
- Receipt: 230 V3AC (255…373V), 50/60 Hz
- Output: 0-Uin (V3AC); 0-500 Hz
- Overload 60s: 150/120 % (constant/quadratic torque)
- Protection type: IP20/JEM1030
- EMV filter class: A (EN55011) or category C2 (EN61800-3)
- Ambient temperature: -10 to +40(60)°C
- Clock frequency: 2.0-16.0 kHz
- Digital display: 4-digit (programmable)
• SPS functions Processes with up to 14 links in function plan logic
• Suitable for permanent magnet-excited motors
• Stable torque in generator operation
• Improved braking performance; Extended functionality for external brakes
• with PM motor drive for more effective energy saving
• Many interfaces available
• with PTC input
• Immediate start of work after engine connection
• Premium functions: Extended SPS; PM engines; servo-lock; STO function
- Engine power: 11,0/15,0 kW (constant/quadratic torque)
- Output current: 54,0/73,6 A (constant/quadratic torque)
- Dimensions: HxBxT 310x180x190 mm
- Receipt: 230 V3AC (255…373V), 50/60 Hz
- Output: 0-Uin (V3AC); 0-500 Hz
- Overload 60s: 150/120 % (constant/quadratic torque)
- Protection type: IP20/JEM1030
- EMV filter class: A (EN55011) or category C2 (EN61800-3)
- Ambient temperature: -10 to +40(60)°C
- Clock frequency: 2.0-16.0 kHz
- Digital display: 4-digit (programmable)
• SPS functions Processes with up to 14 links in function plan logic
• Suitable for permanent magnet-excited motors
• Stable torque in generator operation
• Improved braking performance; Extended functionality for external brakes
• with PM motor drive for more effective energy saving
• Many interfaces available
• with PTC input
• Immediate start of work after engine connection
• Premium functions: Extended SPS; PM engines; servo-lock; STO function
incl. SPS - Industry 4.0/IoT Ready with real-time clock
- Power & Power (Out):
11,0 kW; 23,5 A with overload ND 120% for 60s, 135% for 2s (standard)
07,5 kW; 16,5 A with overload HD 150% for 60s, 180% for 2s (heavy load) - Dimensions 171*411,5*231 mm (BxHxT *with DC choke)
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type
IP20...75 kW (HD) including NEMA terminal box, otherwise IP00 (optional...90 kW (HD) in IP54) - EMV filter class: Category C2 (EN61800-3) or A (EN55011)...37 kW (HD)
- Ambient temperature -10... +60°C (storage temperature -25...+70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
incl. SPS - Industry 4.0/IoT Ready with real-time clock
- Power & Power (Out):
15,0 kW; 31,7 A with overload ND 120% for 60s, 135% for 2s (standard)
11,0 kW; 23,5 A with overload HD 150% for 60s, 180% for 2s (heavy load) - Dimensions 211*554,5*232 mm (BxHxT *with DC choke)
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type
IP20...75 kW (HD) including NEMA terminal box, otherwise IP00 (optional...90 kW (HD) in IP54) - EMV filter class: Category C2 (EN61800-3) or A (EN55011)...37 kW (HD)
- Ambient temperature -10... +60°C (storage temperature -25...+70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
incl. SPS - Industry 4.0/IoT Ready with real-time clock
- Power & Power (Out):
280 kW; 550 A with overload ND 120% for 60s, 135% for 2s (standard)
220 kW; 427 A with overload HD 150% for 60s, 180% for 2s (heavy load) - Dimensions 585*950 (1190)*377 mm (BxHxT) *with DC choke
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type
IP20...75 kW (HD) including NEMA terminal box, otherwise IP00 (optional...90 kW (HD) in IP54) - EMV filter class: Category C2 (EN61800-3) or A (EN55011)...37 kW (HD)
- Ambient temperature -10... +60°C (storage temperature -25...+70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
incl. SPS - Industry 4.0/IoT Ready with real-time clock
- Power & Power (Out):
315 kW; 616 A with overload ND 120% for 60s, 135% for 2s (standard)
280 kW; 550 A with overload HD 150% for 60s, 180% for 2s (heavy load) - Dimensions 585*950 (1190)*377 mm (BxHxT) *with DC choke
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type
IP20...75 kW (HD) including NEMA terminal box, otherwise IP00 (optional...90 kW (HD) in IP54) - EMV filter class: Category C2 (EN61800-3) or A (EN55011)...37 kW (HD)
- Ambient temperature -10... +60°C (storage temperature -25...+70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
Items 1 - 10 of 10