TOSHIBA
Items 1 - 8 of 8
- Engine power 0,55 kW
- Output current 2,4 A
- Dimensions WxHxD 72x130x121 mm
- Output voltage 50... 330 V3AC depending on input voltage
- Output frequency 0,1... 400 Hz
- Input voltage 170... 264 V1AC ±10%
- input frequency 50... 60 Hz ±5%
- Overload 150% for 60 seconds
- Protection type IP20
- Ambient temperature -10...+60°C13
- Radio interference suppression filter IEC61800-3 C1 to 5 m, C2 to 10m motor line
for TOSHIBA - frequency inverter of the series VF-S15 as a sub-filter according to EN 60939-1, UL 1283, RoHS and low voltage directive manufactured The interference suppression filters are also suitable for the dual-rating functions. the TOSHIBA frequency inverter VF-S15. 250V single-phase; leakage current 0,2mA; Clamping (mm2) < 6 Dimensions A - B - C [mm] 180 - 76 - 40 Mount D - E [mm] 168 - 50; borehole M4
for TOSHIBA - frequency inverter 480V three-phase; 0,2mA nom.; Clamping < 6 mm2; Dimensions A - B - C [mm] 170 - 109 - 45
- Engine power: 0,37...0,55/0,75 kW (constant/quadratic torque)
- Output current: 3,30/4,10 A (constant/quadratic torque)
- Dimensions: HxBxT 72x120x130 mm
- Receipt: 400 V3AC (323…550V), 50/60 Hz
- Output: 0-Uin (V3AC); 0-500 Hz
- Overload 60s: 150/120 % (constant/quadratic torque)
- Protection type: IP20/JEM1030
- EMV filter class: A (EN55011) or category C2 (EN61800-3)
- Ambient temperature: -10 to +40(60)°C
- Clock frequency: 2.0-16.0 kHz
- Digital display: 4-digit (programmable)
• SPS functions Processes with up to 14 links in function plan logic
• Suitable for permanent magnet-excited motors
• Stable torque in generator operation
• Improved braking performance; Extended functionality for external brakes
• with PM motor drive for more effective energy saving
• Many interfaces available
• with PTC input
• Immediate start of work after engine connection
• Premium functions: Extended SPS; PM engines; servo-lock; STO function
incl. SPS - Industry 4.0/IoT Ready with real-time clock
- Power & Power (Out):
0,75 kW; 2,2 A with overload ND 120% for 60s, 135% for 2s (standard)
0,55 kW; 1,5 A with overload HD 150% for 60s, 180% for 2s (heavy load) - Dimensions 146x350x202 mm (BxHxT) *with DC choke
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type
IP20...75 kW (HD) including NEMA terminal box, otherwise IP00 (optional...90 kW (HD) in IP54) - EMV filter class: Category C2 (EN61800-3) or A (EN55011)...37 kW (HD)
- Ambient temperature -10... +60°C (storage temperature -25...+70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
- Engine power: 0,55/0,75 kW (constant/quadratic torque)
- Output current: 1,50/2,10 A (constant/quadratic torque)
- Dimensions: HxBxT 107x153x130 mm
- Receipt: 400 V3AC (323…550V), 50/60 Hz
- Output: 0-Uin (V3AC); 0-500 Hz
- Overload 60s: 150/120 % (constant/quadratic torque)
- Protection type: IP20/JEM1030
- EMV filter class: A (EN55011) or category C2 (EN61800-3)
- Ambient temperature: -10 to +40(60)°C
- Clock frequency: 2.0-16.0 kHz
- Digital display: 4-digit (programmable)
• SPS functions Processes with up to 14 links in function plan logic
• Suitable for permanent magnet-excited motors
• Stable torque in generator operation
• Improved braking performance; Extended functionality for external brakes
• with PM motor drive for more effective energy saving
• Many interfaces available
• with PTC input
• Immediate start of work after engine connection
• Premium functions: Extended SPS; PM engines; servo-lock; STO function
incl. SPS - Industry 4.0/IoT Ready with real-time clock
- Receipt
400 V3AC (323…528 V), 50/60 ±5% Hz …132 kW (HD) - Output
0...Uin (V3AC); 0,01…590 Hz - Overload:
180%:2,0 s; 150%:60 s or 135%:2 s / 120%:60s square load - Protection type...90 kW (HD) in IP55
- EMV filter class: Category C2 (EN61800-3) or A (EN55011)...37 kW (HD)
- Ambient temperature -10... +60°C (storage temperature -25... +70°C)
- Relative humidity: 5...95% (free of condensation and steam)
- Clock frequency: 2.0…16.0 kHz
- Brake chopper: integrated...75 (+160) kW (HD), otherwise optional
- DC choke: Dual DC throttle...132 kW fixed, otherwise removable
- Standards CE, UL and CSA
- Fieldbus interfaces Optional DeviceNet®, PROFIBUS®DP, EtherNet/IP®,
Profinet®, EtherCAT®, Modbus/TCP
- Motorpower:0,55/0,75 kW (constant/quadratic torque)
- Output current: 3,3/4,1 A (constant/quadratic torque)
- Dimensions: HxBxT 130x72x120 mm
- Receipt: 230 V3AC (200…240V), 50/60 Hz
- Output: 0-Uin (V3AC); 0-500 Hz
- Overload 60s: 150/120 % (constant/quadratic torque)
- Protection type: IP20/JEM1030
- EMV filter class: A (EN55011) or category C2 (EN61800-3)
- Ambient temperature: -10 to +40(60)°C
- Clock frequency: 2.0-16.0 kHz
- Digital display: 4-digit (programmable)
• SPS functions Processes with up to 14 links in function plan logic
• Suitable for permanent magnet-excited motors
• Stable torque in generator operation
• Improved braking performance; Extended functionality for external brakes
• with PM motor drive for more effective energy saving
• Many interfaces available
• with PTC input
• Immediate start of work after engine connection
• Premium functions: Extended SPS; PM engines; servo-lock; STO function
Items 1 - 8 of 8