7IK200VJS3T2-9RHS general-purpose motor K2S series
7IK200VJS3T2-5S general-purpose motor K2S series
7IK200VJS3T2-5RHS general-purpose motor K2S series
7IK200VJS3T2-50S general-purpose motor K2S series
7IK200VJS3T2-50RHS general-purpose motor K2S series
7IK200VJS3T2-30S general-purpose motor K2S series
7IK200VJS3T2-30RHS general-purpose motor K2S series
7IK200VJS3T2-20S general-purpose motor K2S series
7IK200VJS3T2-18RHS general-purpose motor K2S series
• Description of Specification Items
- Frame Size: 110 mm
- Output Power: 200 W
- series: KIIS series
- Type: With Terminal Box
- Shaft/Gear Type: Hollow right-angle shaft hypoid GV gearhead
- Gear Ratio: 180
- Time Rating: Continuous
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 1.10 A
Three-Phase 200 VAC / 60 Hz / 1.00 A - The Speed When Installing gearhead: Three-Phase 200 VAC / 50 Hz: 8.3 r/min
Three-Phase 200 VAC / 60 Hz: 10 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 200 VAC / 50 Hz: 60 N·m
Three-Phase 200 VAC / 60 Hz: 60 N·m - Permissible Inertia J: 37000×10-4 kg·m2 (Instantaneous Stop: 5000×10-4 kg·m2)
- Mass: 9.6 kg
• The speed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is a maximum of 10% less, depending on the load.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter. Keep the motor operating ambient temperature between 0~+40˚C.
[Note]
Do not perform instantaneous bi-directional operations.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter. Keep the motor operating ambient temperature between 0~+40˚C.
[Note]
Do not perform instantaneous bi-directional operations.
- Frame Size: 110 mm
- Output Power: 200 W
- series: KIIS series
- Type: With Terminal Box
- Shaft/Gear Type: Parallel Shaft Combination Type
- Gear Ratio: 15
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 1.10 A
Three-Phase 200 VAC / 60 Hz / 1.00 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1690 mN·m
Three-Phase 200 VAC / 60 Hz: 1410 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1350 mN·m / 1420 r/min
Three-Phase 200 VAC / 60 Hz: 1130 mN·m / 1700 r/min - The Speed When Installing gearhead: Three-Phase 200 VAC / 50 Hz: 100 r/min
Three-Phase 200 VAC / 60 Hz: 120 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 200 VAC / 50 Hz: 18.2 N·m
Three-Phase 200 VAC / 60 Hz: 15.3 N·m - Permissible Inertia J: 1000×10-4 kg·m2 (Instantaneous Stop: 450×10-4 kg·m2)
- Mass: 7.3 kg
• The speed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is a maximum of 10% less, depending on the load.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
- Frame Size: 110 mm
- Output Power: 200 W
- series: KIIS series
- Type: With Terminal Box
- Shaft/Gear Type: Hollow right-angle shaft hypoid GV gearhead
- Gear Ratio: 15
- Time Rating: Continuous
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 1.10 A
Three-Phase 200 VAC / 60 Hz / 1.00 A - The Speed When Installing gearhead: Three-Phase 200 VAC / 50 Hz: 100 r/min
Three-Phase 200 VAC / 60 Hz: 120 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 200 VAC / 50 Hz: 14.8 N·m
Three-Phase 200 VAC / 60 Hz: 12.4 N·m - Permissible Inertia J: 1000×10-4 kg·m2 (Instantaneous Stop: 450×10-4 kg·m2)
- Mass: 9.6 kg
• The speed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is a maximum of 10% less, depending on the load.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter. Keep the motor operating ambient temperature between 0~+40˚C.
[Note]
Do not perform instantaneous bi-directional operations.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter. Keep the motor operating ambient temperature between 0~+40˚C.
[Note]
Do not perform instantaneous bi-directional operations.
7IK200VJS3T2-10S general-purpose motor K2S series
- Frame Size: 110 mm
- Output Power: 200 W
- series: KIIS series
- Type: With Terminal Box
- Shaft/Gear Type: Parallel Shaft Combination Type
- Gear Ratio: 100
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 1.10 A
Three-Phase 200 VAC / 60 Hz / 1.00 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1690 mN·m
Three-Phase 200 VAC / 60 Hz: 1410 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1350 mN·m / 1420 r/min
Three-Phase 200 VAC / 60 Hz: 1130 mN·m / 1700 r/min - The Speed When Installing gearhead: Three-Phase 200 VAC / 50 Hz: 15 r/min
Three-Phase 200 VAC / 60 Hz: 18 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 200 VAC / 50 Hz: 70 N·m
Three-Phase 200 VAC / 60 Hz: 70 N·m - Permissible Inertia J: 18000×10-4 kg·m2 (Instantaneous Stop: 5000×10-4 kg·m2)
- Mass: 8.4 kg
• The speed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is a maximum of 10% less, depending on the load.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
- Frame Size: 110 mm
- Output Power: 200 W
- series: KIIS series
- Type: With Terminal Box
- Shaft/Gear Type: Hollow right-angle shaft hypoid GV gearhead
- Gear Ratio: 100
- Time Rating: Continuous
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 1.10 A
Three-Phase 200 VAC / 60 Hz / 1.00 A - The Speed When Installing gearhead: Three-Phase 200 VAC / 50 Hz: 15 r/min
Three-Phase 200 VAC / 60 Hz: 18 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 200 VAC / 50 Hz: 54.5 N·m
Three-Phase 200 VAC / 60 Hz: 54.5 N·m - Permissible Inertia J: 18000×10-4 kg·m2 (Instantaneous Stop: 5000×10-4 kg·m2)
- Mass: 9.6 kg
• The speed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is a maximum of 10% less, depending on the load.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter. Keep the motor operating ambient temperature between 0~+40˚C.
[Note]
Do not perform instantaneous bi-directional operations.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter. Keep the motor operating ambient temperature between 0~+40˚C.
[Note]
Do not perform instantaneous bi-directional operations.
- Frame Size: 110 mm
- Output Power: 200 W
- series: KIIS series
- Type: With Terminal Box
- Shaft/Gear Type: Pinion Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Rotation Direction: Depends on the combination gearhead.
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 1.10 A
Three-Phase 200 VAC / 60 Hz / 1.00 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1690 mN·m
Three-Phase 200 VAC / 60 Hz: 1410 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1350 mN·m / 1420 r/min
Three-Phase 200 VAC / 60 Hz: 1130 mN·m / 1700 r/min - Mass: 5.4 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
- Frame Size: 110 mm
- Output Power: 200 W
- series: KIIS series
- Type: With Terminal Box
- Shaft/Gear Type: Pinion Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Rotation Direction: Depends on the combination gearhead.
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.52 A
Three-Phase400 VAC / 50 Hz / 0.56 A
Three-Phase400 VAC / 60 Hz / 0.51 A
Three-Phase415 VAC / 50 Hz / 0.57 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1400 mN·m
Three-Phase 380 VAC / 60 Hz: 1300 mN·m
Three-Phase 400 VAC / 50 Hz: 1400 mN·m
Three-Phase 400 VAC / 60 Hz: 1300 mN·m
Three-Phase 415 VAC / 50 Hz: 1400 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1350 mN·m / 1420 r/min
Three-Phase 380 VAC / 60 Hz: 1130 mN·m / 1700 r/min
Three-Phase 400 VAC / 50 Hz: 1350 mN·m / 1420 r/min
Three-Phase 400 VAC / 60 Hz: 1130 mN·m / 1700 r/min
Three-Phase 415 VAC / 50 Hz: 1350 mN·m / 1420 r/min - Mass: 5.4 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
- Frame Size: 110 mm
- Output Power: 200 W
- series: KIIS series
- Type: With Terminal Box
- Shaft/Gear Type: Pinion Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Rotation Direction: Depends on the combination gearhead.
- Voltage/ Frequency/ Current: Three-Phase 220 VAC / 50 Hz / 1.00 A
Three-Phase 220 VAC / 60 Hz / 0.90 A
Three-Phase 230 VAC / 50 Hz / 1.02 A
Three-Phase 230 VAC / 60 Hz / 0.89 A
Three-Phase 240 VAC / 50 Hz / 1.06 A
Three-Phase 240 VAC / 60 Hz / 0.90 A - Starting Torque (Motor Shaft): Three-Phase 220 VAC / 50 Hz: 1690 mN·m
Three-Phase 220 VAC / 60 Hz: 1410 mN·m
Three-Phase 230 VAC / 50 Hz: 1690 mN·m
Three-Phase 230 VAC / 60 Hz: 1410 mN·m
Three-Phase 240 VAC / 50 Hz: 1690 mN·m
Three-Phase 240 VAC / 60 Hz: 1410 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 220 VAC / 50 Hz: 1350 mN·m / 1420 r/min
Three-Phase 220 VAC / 60 Hz: 1130 mN·m / 1700 r/min
Three-Phase 230 VAC / 50 Hz: 1350 mN·m / 1420 r/min
Three-Phase 230 VAC / 60 Hz: 1130 mN·m / 1700 r/min
Three-Phase 240 VAC / 50 Hz: 1350 mN·m / 1420 r/min
Three-Phase 240 VAC / 60 Hz: 1130 mN·m / 1700 r/min - Mass: 5.4 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
- Frame Size: 110 mm
- Output Power: 200 W
- series: KIIS series
- Type: With Terminal Box
- Shaft/Gear Type: Hollow right-angle shaft hypoid GV gearhead
- Gear Ratio: 9
- Time Rating: Continuous
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.52 A
Three-Phase400 VAC / 50 Hz / 0.56 A
Three-Phase400 VAC / 60 Hz / 0.51 A
Three-Phase415 VAC / 50 Hz / 0.57 A - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 166 r/min
Three-Phase 380 VAC / 60 Hz: 200 r/min
Three-Phase 400 VAC / 50 Hz: 166 r/min
Three-Phase 400 VAC / 60 Hz: 200 r/min
Three-Phase 415 VAC / 50 Hz: 166 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 8.9 N·m
Three-Phase 380 VAC / 60 Hz: 7.4 N·m
Three-Phase 400 VAC / 50 Hz: 8.9 N·m
Three-Phase 400 VAC / 60 Hz: 7.4 N·m
Three-Phase 415 VAC / 50 Hz: 8.9 N·m - Permissible Inertia J: 320×10-4 kg·m2 (Instantaneous Stop: 162×10-4 kg·m2)
- Mass: 9.6 kg
• The speed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is a maximum of 10% less, depending on the load.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter. Keep the motor operating ambient temperature between 0~+40˚C.
[Note]
Do not perform instantaneous bi-directional operations.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter. Keep the motor operating ambient temperature between 0~+40˚C.
[Note]
Do not perform instantaneous bi-directional operations.
- Frame Size: 110 mm
- Output Power: 200 W
- series: KIIS series
- Type: With Terminal Box
- Shaft/Gear Type: Parallel Shaft Combination Type
- Gear Ratio: 5
- Time Rating: Continuous
- Rotation Direction: same direction as the motor shaft
- Voltage/ Frequency/ Current: Three-Phase380 VAC / 50 Hz / 0.56 A
Three-Phase380 VAC / 60 Hz / 0.52 A
Three-Phase400 VAC / 50 Hz / 0.56 A
Three-Phase400 VAC / 60 Hz / 0.51 A
Three-Phase415 VAC / 50 Hz / 0.57 A - Starting Torque (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1400 mN·m
Three-Phase 380 VAC / 60 Hz: 1300 mN·m
Three-Phase 400 VAC / 50 Hz: 1400 mN·m
Three-Phase 400 VAC / 60 Hz: 1300 mN·m
Three-Phase 415 VAC / 50 Hz: 1400 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 380 VAC / 50 Hz: 1350 mN·m / 1420 r/min
Three-Phase 380 VAC / 60 Hz: 1130 mN·m / 1700 r/min
Three-Phase 400 VAC / 50 Hz: 1350 mN·m / 1420 r/min
Three-Phase 400 VAC / 60 Hz: 1130 mN·m / 1700 r/min
Three-Phase 415 VAC / 50 Hz: 1350 mN·m / 1420 r/min - The Speed When Installing gearhead: Three-Phase 380 VAC / 50 Hz: 300 r/min
Three-Phase 380 VAC / 60 Hz: 360 r/min
Three-Phase 400 VAC / 50 Hz: 300 r/min
Three-Phase 400 VAC / 60 Hz: 360 r/min
Three-Phase 415 VAC / 50 Hz: 300 r/min - Permissible Torque of gearhead Output Shaft: Three-Phase 380 VAC / 50 Hz: 6.1 N·m
Three-Phase 380 VAC / 60 Hz: 5.1 N·m
Three-Phase 400 VAC / 50 Hz: 6.1 N·m
Three-Phase 400 VAC / 60 Hz: 5.1 N·m
Three-Phase 415 VAC / 50 Hz: 6.1 N·m - Permissible Inertia J: 100×10-4 kg·m2 (Instantaneous Stop: 50×10-4 kg·m2)
- Mass: 7.3 kg
• The speed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is a maximum of 10% less, depending on the load.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.