ORIENTAL MOTOR
Items 1 - 17 of 17
Product type:
motor
Power supply / number of poles:
JS three-phase 200 VAC, 4 Pole
Reset all filters
• Description of Specification Items
- Frame Size: 80 mm
- Output Power: 25 W
- Type: With Terminal Box
- Shaft/Gear Type: Pinion Shaft
- Shaft Material: iron
- Gear Ratio: -
- Time Rating: Continuous
- Rotation Direction: Depends on the combination gearhead.
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 0.23 A
Three-Phase 200 VAC / 60 Hz / 0.21 A
Three-Phase 220 VAC / 60 Hz / 0.21 A
Three-Phase 230 VAC / 60 Hz / 0.22 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 240 mN·m
Three-Phase 200 VAC / 60 Hz: 160 mN·m
Three-Phase 220 VAC / 60 Hz: 160 mN·m
Three-Phase 230 VAC / 60 Hz: 160 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 190 mN·m / 1300 r/min
Three-Phase 200 VAC / 60 Hz: 160 mN·m / 1550 r/min
Three-Phase 220 VAC / 60 Hz: 160 mN·m / 1600 r/min
Three-Phase 230 VAC / 60 Hz: 160 mN·m / 1600 r/min - Mass: 1.8 kg
- Frame Size: 90 mm
- Output Power: 100 W
- series: KIIS series
- Type: Lead Wire Type
- Shaft/Gear Type: Round Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 0.60 A
Three-Phase 200 VAC / 60 Hz / 0.53 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 850 mN·m
Three-Phase 200 VAC / 60 Hz: 700 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 690 mN·m / 1400 r/min
Three-Phase 200 VAC / 60 Hz: 570 mN·m / 1680 r/min - Motor Section Mass: 2.9 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
5IK100VA-JSM motor with electromagnetic brake K2S series
5IK100VA-JSMT2 motor with electromagnetic brake K2S series
- Frame Size: 90 mm
- Output Power: 100 W
- series: KIIS series
- Type: With Terminal Box
- Shaft/Gear Type: Round Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 0.60 A
Three-Phase 200 VAC / 60 Hz / 0.53 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 850 mN·m
Three-Phase 200 VAC / 60 Hz: 700 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 690 mN·m / 1400 r/min
Three-Phase 200 VAC / 60 Hz: 570 mN·m / 1680 r/min - Motor Section Mass: 3.2 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
5IK100VGVR-JS general-purpose motor K2S series
- Frame Size: 90 mm
- Output Power: 100 W
- series: KIIS series
- Type: cable Type
- Shaft/Gear Type: Pinion Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 0.60 A
Three-Phase 200 VAC / 60 Hz / 0.53 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 850 mN·m
Three-Phase 200 VAC / 60 Hz: 700 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 690 mN·m / 1400 r/min
Three-Phase 200 VAC / 60 Hz: 570 mN·m / 1680 r/min - Electromagnetic Brake Brake Type: Power off activated type
- Electromagnetic Brake Voltage/ Frequency/ Current/ Input: single-Phase 200 VAC / 50 Hz / 0.04 A / 6 W
single-Phase 200 VAC / 60 Hz / 0.04 A / 6 W - Electromagnetic Brake Static Friction Torque (Motor Shaft): 500 mN·m
- Mass: 3.6 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
- Frame Size: 90 mm
- Output Power: 100 W
- series: KIIS series
- Type: With Terminal Box
- Shaft/Gear Type: Pinion Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 0.60 A
Three-Phase 200 VAC / 60 Hz / 0.53 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 850 mN·m
Three-Phase 200 VAC / 60 Hz: 700 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 690 mN·m / 1400 r/min
Three-Phase 200 VAC / 60 Hz: 570 mN·m / 1680 r/min - Electromagnetic Brake Brake Type: Power off activated type
- Electromagnetic Brake Voltage/ Frequency/ Current/ Input: single-Phase 200 VAC / 50 Hz / 0.04 A / 6 W
single-Phase 200 VAC / 60 Hz / 0.04 A / 6 W - Electromagnetic Brake Static Friction Torque (Motor Shaft): 500 mN·m
- Mass: 3.9 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
5IK60VA-JS general-purpose motor K2S series
- Frame Size: 90 mm
- Output Power: 60 W
- series: KIIS series
- Type: cable Type
- Shaft/Gear Type: Round Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 0.40 A
Three-Phase 200 VAC / 60 Hz / 0.35 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 600 mN·m
Three-Phase 200 VAC / 60 Hz: 500 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 410 mN·m / 1400 r/min
Three-Phase 200 VAC / 60 Hz: 350 mN·m / 1680 r/min - Electromagnetic Brake Brake Type: Power off activated type
- Electromagnetic Brake Voltage/ Frequency/ Current/ Input: single-Phase 200 VAC / 50 Hz / 0.04 A / 6 W
single-Phase 200 VAC / 60 Hz / 0.04 A / 6 W - Electromagnetic Brake Static Friction Torque (Motor Shaft): 500 mN·m
- Motor Section Mass: 3.0 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
- Frame Size: 90 mm
- Output Power: 60 W
- series: KIIS series
- Type: With Terminal Box
- Shaft/Gear Type: Round Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 0.40 A
Three-Phase 200 VAC / 60 Hz / 0.35 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 600 mN·m
Three-Phase 200 VAC / 60 Hz: 500 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 410 mN·m / 1400 r/min
Three-Phase 200 VAC / 60 Hz: 350 mN·m / 1680 r/min - Electromagnetic Brake Brake Type: Power off activated type
- Electromagnetic Brake Voltage/ Frequency/ Current/ Input: single-Phase 200 VAC / 50 Hz / 0.04 A / 6 W
single-Phase 200 VAC / 60 Hz / 0.04 A / 6 W - Electromagnetic Brake Static Friction Torque (Motor Shaft): 500 mN·m
- Motor Section Mass: 3.3 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
5IK60VA-JST2 general-purpose motor K2S series
5IK60VGVH-JS general-purpose motor K2S series
- Frame Size: 90 mm
- Output Power: 60 W
- series: KIIS series
- Type: cable Type
- Shaft/Gear Type: Pinion Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 0.40 A
Three-Phase 200 VAC / 60 Hz / 0.35 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 600 mN·m
Three-Phase 200 VAC / 60 Hz: 500 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 410 mN·m / 1400 r/min
Three-Phase 200 VAC / 60 Hz: 350 mN·m / 1680 r/min - Electromagnetic Brake Brake Type: Power off activated type
- Electromagnetic Brake Voltage/ Frequency/ Current/ Input: single-Phase 200 VAC / 50 Hz / 0.04 A / 6 W
single-Phase 200 VAC / 60 Hz / 0.04 A / 6 W - Electromagnetic Brake Static Friction Torque (Motor Shaft): 500 mN·m
- Mass: 3.0 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
- Frame Size: 90 mm
- Output Power: 60 W
- series: KIIS series
- Type: With Terminal Box
- Shaft/Gear Type: Pinion Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 0.40 A
Three-Phase 200 VAC / 60 Hz / 0.35 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 600 mN·m
Three-Phase 200 VAC / 60 Hz: 500 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 410 mN·m / 1400 r/min
Three-Phase 200 VAC / 60 Hz: 350 mN·m / 1680 r/min - Electromagnetic Brake Brake Type: Power off activated type
- Electromagnetic Brake Voltage/ Frequency/ Current/ Input: single-Phase 200 VAC / 50 Hz / 0.04 A / 6 W
single-Phase 200 VAC / 60 Hz / 0.04 A / 6 W - Electromagnetic Brake Static Friction Torque (Motor Shaft): 500 mN·m
- Mass: 3.3 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
7IK200VAS-JS3T2 general-purpose motor K2S series
- Frame Size: 110 mm
- Output Power: 200 W
- series: KIIS series
- Type: With Terminal Box
- Shaft/Gear Type: Pinion Shaft Type
- Gear Ratio: -
- Time Rating: Continuous
- Rotation Direction: Depends on the combination gearhead.
- Voltage/ Frequency/ Current: Three-Phase 200 VAC / 50 Hz / 1.10 A
Three-Phase 200 VAC / 60 Hz / 1.00 A - Starting Torque (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1690 mN·m
Three-Phase 200 VAC / 60 Hz: 1410 mN·m - Rated torque/ Rated Speed (Motor Shaft): Three-Phase 200 VAC / 50 Hz: 1350 mN·m / 1420 r/min
Three-Phase 200 VAC / 60 Hz: 1130 mN·m / 1700 r/min - Mass: 5.4 kg
[Note]
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
• No built-in overheat protection device (thermal protector). When there is an overload or the output shaft is locked, use the electromagnetic switch and the inverter's electronic thermal function to prevent motor burnout.
• Use an inverter setting frequency of 120 Hz or less when driving in combination with the inverter.
Items 1 - 17 of 17