MP42.22 — Permanent magnet DC motor
| Parameter |
Value |
Unit |
| Operating data · Operating point 1 (12 V DC) |
| Rated voltage |
12 |
V DC |
| Output power |
22 |
W |
| Speed |
3,000 |
min⁻¹ |
| Rated current |
2.7 |
A |
| Rated torque |
0.07 |
Nm |
| Maximum torque |
0.3 |
Nm |
| Duty type |
S1 |
|
| Maximum current |
11 |
A |
| Armature resistance |
0.9 |
Ω |
| Armature inductance |
2 |
mH |
| Operating data · Operating point 2 (24 V DC) |
| Rated voltage |
24 |
V DC |
| Output power |
22 |
W |
| Speed |
3,000 |
min⁻¹ |
| Rated current |
1.4 |
A |
| Rated torque |
0.07 |
Nm |
| Maximum torque |
0.3 |
Nm |
| Duty type |
S1 |
|
| Maximum current |
5.5 |
A |
| Armature resistance |
3 |
Ω |
| Armature inductance |
6 |
mH |
| Operating data · Operating point 3 (48 V DC) |
| Rated voltage |
48 |
V DC |
| Output power |
22 |
W |
| Speed |
3,000 |
min⁻¹ |
| Rated current |
0.7 |
A |
| Rated torque |
0.07 |
Nm |
| Maximum torque |
0.3 |
Nm |
| Duty type |
S1 |
|
| Maximum current |
2.7 |
A |
| Armature resistance |
11 |
Ω |
| Armature inductance |
25 |
mH |
| Operating data · Operating point 4 (170 V DC) |
| Rated voltage |
170 |
V DC |
| Output power |
On request |
W |
| Speed |
On request |
min⁻¹ |
| Rated current |
0.2 |
A |
| Rated torque |
On request |
Nm |
| Maximum torque |
On request |
Nm |
| Duty type |
S1 |
|
| Maximum current |
0.76 |
A |
| Armature resistance |
On request |
Ω |
| Armature inductance |
On request |
mH |
| Design and mechanics |
| Housing diameter |
65 |
mm |
| Article weight |
0.85 |
kg |
| Mounting |
Mini flange |
|
| Bolt circle |
33 |
mm |
| Pilot diameter |
On request |
mm |
| Shaft Ø × length |
6 × 20 |
mm |
| Base motor rotor inertia |
0.00003 |
kg·m² |
| Equipment |
| Motor design |
Permanent magnet DC motor |
|
| Degree of protection |
IP40 |
|
| Insulation class |
F |
|
| Cooling |
Without fan |
|
| Connection |
Lead wires |
|
| Bearings |
Ball bearings |
|
Series illustration; see data for configuration.
Unspecified values or values awaiting confirmation: on request. S6 duty and permissible overload: on request. Maximum current is not a permissible continuous current.