KEMMERICH ELEKTROMOTOREN
0,75/0,95 kW; S1; 1360/2780 min-1; 400V Y/YY 50 Hz 3AC 2,1/2,5 A; 5,23/3,26 Nm
attracting current 3,1/3,8 x In; starting torque 1,7/1,9 x Mn; Tilting moment 1,8/2,0 x Mn
Efficiency at nominal load 65%/60%
Power values fan design (square torque)
0,25/1,00 kW; S1; 1370/2780 1/min; 400VY/YY 50 Hz 3AC; 0,75/2,32 A; 1,75/3,44 Nm
attracting current 3,0/3,8 x In; starting torque 1,6/1,9 x Mn; tilting moment 1,7/2,0 Mn
Power values correspond to fan design (square torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø19 x 40 mm; heat class 155(F); Housing material up to frame size 132 aluminium, from frame size 160 grey cast iron; rated power at coolant temperature -20...40° C and up to 1000 m above NN; Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; moment of inertia 0,001874 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
1,40/2,00 kW; S1; 1405/2750 1/min; 400V ∆/YY 50 Hz 3AC; 2,8/3,1 A; 9,52/6,94 Nm
Power values correspond to basic design (constant torque)
attracting current 4,4/4,4 x In; starting torque 1,8/1,8 x Mn; tilting moment 2,2/2,2 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø24 x 50 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6205.ZZ.C3; Camp BS: 6205.ZZ.C3; moment of inertia 0,0028 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010
- 2,50/3,30 kW
- S1
- 1380/2785 1/min
- 400V ∆/YY 50 Hz 3AC
- 4,2/5,3 A
- 17,3/11,3 Nm
- Power values correspond to basic design (constant torque)
- attracting current 4,8/4,9 x In
- starting torque 1,7/1,8 x Mn
- tilting moment 2,0/2,2 x Mn
- IEC 60034-1 design
- sound limit value according to IEC 60034-9
- shaft Ø28 x 60 mm
- heat class 155(F)
- in the case of B3 design, feet screwed to frame size132
- Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron
- Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6206.ZZ.C3
- Camp BS: 6206.ZZ.C3
- moment of inertia 0,0065 kgm2
- half-wedge weighting species
- vibration stage "A"
- terminal box layer at the top
- clamp/strand number 6
- the possibility of rotation of the terminal box yes
- Paint RAL5010
0,30/0,55 kW; S1; 660/1350 1/min; 400V ∆/YY 50 Hz 3AC; 1,5/1,4 A; 4,34/3,89 Nm
attracting current 2,0/2,7 x In; starting torque 1,5/1,5 x Mn; Tilting moment 1,5/1,5 x Mn
Efficiency at nominal load 48%/64%
Power values correspond to basic design (constant torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø19 x 40 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; moment of inertia 0,00207 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
2,00/2,60 kW; S1; 1395/2810 1/min; 400V ∆/YY 50 Hz 3AC; 4,2/5,3 A; 13,7/8,8 Nm
Power values correspond to basic version D / YY, 6 clamps (constant torque)
attracting current 4,8/4,7 x In; starting torque 1,6/1,8 x Mn; tilting moment 2,1/2,4 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø28 x 60 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6206.ZZ.C3; Camp BS: 6206.ZZ.C3; moment of inertia 0,006 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010
0,70/1,25 kW; S1; 715/1425 1/min; 400V ∆/YY 50 Hz 3AC; 2,8/2,7 A; 9,35/8,38 Nm
attracting current 3,6/5,1 x In; starting torque 2,2/1,7 x Mn; Tilting moment 2,8/2,5 x Mn
Efficiency at nominal load 64%/78%
Power values correspond to basic design (constant torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø28 x 60 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6206.ZZ.C3; Camp BS: 6206.ZZ.C3; moment of inertia 0,0088 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
0,90/1,70 kW; S1; 715/1415 1/min; 400V ∆/YY 50 Hz 3AC; 3,2/3,7 A; 12,0/11,5 Nm
Power values correspond to basic design (constant torque)
attracting current 4,0/5,1 x In; starting torque 2,2/1,3 x Mn; tilting moment 3,1/2,3 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø28 x 60 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6206.ZZ.C3; Camp BS: 6206.ZZ.C3; moment of inertia 0,0094 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010
0,21/0,28 kW; S1; 1400/2800 1/min; 400V ∆/YY 50 Hz 3AC; 0,95/1,25 A; 1,43/0,96 Nm
attracting current 3,2/3,2 x In; starting torque 1,6/1,6 x Mn; Tilting moment 2,0/1,8 x Mn
Efficiency at nominal load 58%/50%
Power values Basic (constant torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø14 x 30 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6203.ZZ.C3; Camp BS: 6203.ZZ.C3; moment of inertia 0,000606 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
0,30/0,45 kW; S1; 1400/2820 1/min; 400V ∆/YY 50 Hz 3AC; 1,20/1,62 A; 2,05/1,52 Nm
attracting current 2,7/4,0 x In; starting torque 2,0/1,7 x Mn; Tilting moment 2,0/1,8 x Mn
Efficiency at nominal load [%] 68/60
Power values correspond to basic design (linear torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø14 x 30 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6203.ZZ.C3; Camp BS: 6203.ZZ.C3; moment of inertia 0,00077 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
attracting current 2,6/2,6 x In; starting torque 1,5/1,5 x Mn; Tilting moment 1,5/1,6 x Mn
Efficiency at nominal load [%] 68/60
Power values correspond to basic design (linear torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø19 x 40 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; moment of inertia 0,001578 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
0,22/0,40 kW; S1; 670/1350 1/min; 400V ∆/YY 50 Hz 3AC; 1,3/1,1 A; 3,13/2,83 Nm
attracting current 2,0/2,8 x In; starting torque 1,5/1,5 x Mn; Tilting moment 1,6/1,5 x Mn
Efficiency at nominal load 46%/60%
Power values correspond to basic design (constant torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø19 x 40 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; moment of inertia 0,001693 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
attracting current 3,7/4,1 x In; starting torque 2,0/1,5 x Mn; Tilting moment 2,2/2,4 x Mn
Efficiency at nominal load [%] 63,7/66,5
Power values correspond to basic design (constant torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø19 x 40 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; moment of inertia 0,001578 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
1,60/2,40 kW; S1; 1405/2750 1/min;
400V ∆/YY 50 Hz 3AC; 3,7/4,8 A; 10,9/8,24 Nm
Power values correspond to basic design (constant torque)
attracting current 5,0/4,8 x In; starting torque 1,9/1,4 x Mn; tilting moment 2,1/2,0 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø24 x 50 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6205.ZZ.C3; Camp BS: 6205.ZZ.C3; moment of inertia 0,0148 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010
0,70/1,10 kW; S1; 935/1410 1/min; 400V ∆/YY 50 Hz 3AC; 2,2/2,9 A; 7,15/7,45 Nm
Power values correspond to basic design (constant torque)
attracting current 2,2/2,9 x In; starting torque 1,6/1,4 x Mn; tilting moment 3,6/4,2 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø24 x 50 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6205.ZZ.C3; Camp BS: 6205.ZZ.C3; moment of inertia 0,0032 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010; Efficiency 63,7%/67,7%
0,55/1,00 kW; S1; 695/1380 1/min; 400V ∆/YY 50 Hz 3AC; 2,1/2,2 A; 7,56/6,92 Nm
attracting current 3,0/3,9 x In; starting torque 1,8/1,4 x Mn; Tilting moment 2,0/2,0 x Mn
Efficiency at nominal load 62%/75%
Power values correspond to basic design (constant torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø24 x 50 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6205.ZZ.C3; Camp BS: 6205.ZZ.C3; moment of inertia 0,0028 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
1,10/1,40 kW; S1; 1410/2785 1/min; 400V ∆/YY 50 Hz 3AC; 2,8/3,1 A; 7,45/4,80 Nm
Power values correspond to basic design (constant torque)
attracting current 4,4/4,5 x In; starting torque 1,6/1,7 x Mn; tilting moment 2,1/2,1 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø24 x 50 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6205.ZZ.C3; Camp BS: 6205.ZZ.C3; moment of inertia 0,0023 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010
0,37/0,75 kW; S1; 705/1385 1/min; 400V ∆/YY 50 Hz 3AC; 1,7/1,7 A; 5,01/5,17 Nm
attracting current 3,0/4,2 x In; starting torque 2,1/1,5 x Mn; Tilting moment 2,3/1,8 x Mn
Efficiency at nominal load 55%/73%
Power values correspond to basic design (constant torque)
IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø24 x 50 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6205.ZZ.C3; Camp BS: 6205.ZZ.C3; moment of inertia 0,0025 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
Power values correspond to basic design (constant torque)
attracting current 6,9/5,9 x In; starting torque 2,7/2,2 x Mn; tilting moment 2,2/2,6 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; heat class 155(F); RAL 5010/C3
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6306.ZZ.C3; Camp BS: 6306.ZZ.C3; Moment of inertia 0,0119 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic;
6 clamps
Power values correspond to Gbasic (constant torque)
attracting current 6,1/6,1 x In; starting torque 1,8/1,7 x Mn; tilting moment 2,6/2,6 Mn
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø28 x 60 mm; Heat class 155(F)
Housing material up to frame size 132 aluminum, from frame size 160 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6204.ZZ.C3; Camp BS: 6204.ZZ.C3; Moment of inertia 0,0009 kgm2
half-wedge weighting species; vibration stage "A"; Fan blades plastic
1,80/4,00 kW; S1; 470/940 1/min; 400V ∆/YY 50 Hz 3AC; 7,4/8,5 A; 36,57/40,64 Nm
Power values correspond to basic design (constant torque)
attracting current 3,3/4,9 x In; starting torque 1,8/1,4 x Mn; tilting moment 2,3/2,1 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø38 x 80 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6308.ZZ.C3; Camp BS: 6308.ZZ.C3; moment of inertia 0,025 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010; Efficiency at 2/4 load 59,0%/82,5% Efficiency at 3/4 load 65,8%/82,3% Efficiency at rated load 68,1%/80,0% Sound pressure level 73/72 dB
3,20/5,40 kW; S1; 710/1415 1/min; 400V ∆/YY 50 Hz 3AC; 8,7/10,4 A; 43,0/36,5 Nm
Power values correspond to basic design (constant torque)
attracting current 4,7/5,4 x In; starting torque 1,9/1,7 x Mn; tilting moment 2,6/2,3 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø38 x 80 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6308.ZZ.C3; Camp BS: 6308.ZZ.C3; moment of inertia 0,0399 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010; Efficiency at 2/4 load 74,8%/84,6% Efficiency at 3/4 load 78,2%/84,4% Efficiency at rated load 78,6%/82,4% Sound pressure level 56/64 dB
4,7/5,70 kW; S1; 1445/2895 1/min; 400V ∆/YY 50 Hz 3AC; 9,3/11,5 A; 33,6/28,5 Nm
Power values correspond to basic design (constant torque)
attracting current 5,6/6,1 x In; starting torque 1,6/1,7 x Mn; tilting moment 2,3/2,4 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø38 x 80 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Ged material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6308.ZZ.C3; Camp BS: 6308.ZZ.C3; moment of inertia 0,029 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010
2,50/4,20 kW; S1; 710/1410 1/min; 400V ∆/YY 50 Hz 3AC; 3,2/3,7 A; 33,6/28,5 Nm
Power values correspond to basic design (constant torque)
attracting current 4,0/5,1 x In; starting torque 1,9/1,5 x Mn; tilting moment 2,5/2,2 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø38 x 80 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6308.ZZ.C3; Camp BS: 6308.ZZ.C3; moment of inertia 0,0319 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010; Efficiency at 2/4 load 73.2%/83.8% Efficiency at 3/4 load 77.0%/83.6% Efficiency at nominal load 77.5%/81.6%
7,20/12,0 kW; S1; 720/1440 1/min; 400V ∆/YY 50 Hz 3AC; 19,4/22,0 A; 95,5/79,6 Nm
Power values correspond to basic design (constant torque)
attracting current 5,6/7,2 x In; starting torque 2,1/1,9 x Mn; tilting moment 2,9/2,7 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø42 x 110 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6309.ZZ.C3; Camp BS: 6309.ZZ.C3; moment of inertia 0,096 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010; Efficiency at 2/4 load 80,2%/87,2% Efficiency at 3/4 load 83,5%/88,0% Efficiency at rated load 83,9%/87,3% Sound pressure level 63/67 dB
4,70/8,40 kW; S1; 725/1435 1/min; 400V ∆/YY 50 Hz 3AC; 13,0/15,5 A; 61,9/55,9 Nm
Power values correspond to basic design (constant torque)
attracting current 5,4/6,2 x In; starting torque 2,0/1,7 x Mn; tilting moment 2,9/2,4 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø42 x 110 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6309.ZZ.C3; Camp BS: 6309.ZZ.C3; moment of inertia 0,07 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010; Efficiency at 2/4 load 77,8%/86,7% Efficiency at 3/4 load 81,7%/87,2% Efficiency at rated load 82,7%/86,1% Sound pressure level 71/67 dB
10,0/15,80 kW; S1; 730/1460 1/min; 400V ∆/YY 50 Hz 3AC; 24,2/29,5 A; 131/103 Nm
Power values correspond to basic design (constant torque)
attracting current 5,2/6,1 x In; starting torque 2,3/2,0 x Mn; tilting moment 2,1/2,1 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø48 x 110 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; rated power at coolant temperature -20...40° C and up to 1000 m above NN; Camp AS: 6311.ZZ.C3; Camp BS: 6311.ZZ.C3; moment of inertia 0,22 kgm2; half-wedge weighting species; vibration stage "A"; Efficiency at 2/4 load [%] 81.6|84.0; Efficiency at 3/4 load [%] 84.5|86.0; Efficiency at nominal load [%] 85.0|86.0 Insulating class F; sound pressure level [dB] 67|67; terminal box position standard above; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010
16/23 kW; S1; 985/1473 min-1; 400V Δ/YY 50 Hz 3AC; 30/42 A; 155/149 Nm
attract current 6,4/6,4xIn; starting torque 1,5/1,5xMn; tilting moment 2,5/2,3xMn
Efficiency 86/87%
Power values Basic design (constant torque)
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø55 x 110 mm; heat class 155(F); incl. 3x PTC temperature sensors
housing material grey cast iron; With bearing post-lubricating device
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6312P63E1; Camp BS: 6312P63E1; Moment of inertia 0,47 kgm2
half-wedge weighting species; vibration stage "A"; Insulation class F
terminal box position on the right-left side possible; bearing lubrication yes; RAL5010Lackierung RAL5010; with 3 PTC resistor PTC - for disconnection (2 terminals)
17/27 kW; S1; 740/1470 min-1; 400V Δ/YY 50 Hz 3AC; 40,0/48,5 A; 219/175 Nm
attract current 6,0/6,9xIn; starting torque 2,7/1,8xMn; tilting moment 2,7/2,4xMn
Efficiency 85,2/87,6%
Power values Basic design (constant torque)
7,0/28 kW; S1; 735/1470 min-1; 400V Y/YY 50 Hz 3AC 14,8/54,0 A; 91/182 Nm
attract current 5,2/6,3xIn; starting torque 1,8/2,1xMn; tilting moment 2,3/2,6xMn
Efficiency 84,5/89,7%
Power values Fan design (square torque)
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø55 x 110 mm; heat class 155(F); incl. 3x PTC temperature sensors
Housing material up to frame size 112 aluminum, from frame size 132 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: NU312.C3; Camp BS: 6312.C3; Moment of inertia 0,47 kgm2
half-wedge weighting species; vibration stage "A"; Insulation class F
sound pressure level 60/69 dB; terminal box position on the right; Number of terminals 9
Paint RAL5010
14/19 kW; S1; 886/1184 min-1; 460V Δ/YY 50 Hz 3AC; 40,0/48,5 A; 155/155 Nm
attract current 6,2/7,1xIn; starting torque 2,3/2,1xMn; tilting moment 2,5/2,7xMn
Efficiency 84,0/86,5%
Power values Basic design (constant torque)
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø55 x 110 mm; heat class 155(F); incl. 3x PTC temperature sensors
housing material grey cast iron; With bearing post-lubricating device
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: 6312P63E1; Camp BS: 6312P63E1; Moment of inertia 0,45 kgm2
half-wedge weighting species; vibration stage "A"; Insulation class F
terminal box position on the right; Number of terminals 6
Paint RAL5010
Power values correspond to basic design (constant torque)
attracting current 5,8/6,2 x In; starting torque 2,1/1,4 x Mn; tilting moment 2,3/2,3 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø55 x 110 mm; heat class 155(F); incl. 3x PTC thermistor temperature sensors; housing material grey cast iron; terminal box position on the right; rated power at coolant temperature -20...40° C and up to 1000 m above NN; Camp AS: 6313.C3; Camp BS: 6313.C3; moment of inertia 0,76 kgm2; half-wedge weighting species; vibration stage "A"; Insulation class F; efficiency 88,5/89,0%; incl. re-lubricating device; cooling IC411; sound pressure level 60/72 dB; terminal box position on the right; terminal number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
Power values correspond to basic design (constant torque)
attracting current 5,5/6,5 x In; starting torque 2,2/1,1 x Mn; tilting moment 2,0/2,5 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø55 x 110 mm; heat class 155(F); incl. 3x PTC thermistor temperature sensors; housing material grey cast iron; terminal box position on the right; rated power at coolant temperature -20...40° C and up to 1000 m above NN; Camp AS: 6315.C3; Camp BS: 6315.C3; moment of inertia 1,4 kgm2; half-wedge weighting species; vibration stage "A"; Insulation class F; efficiency 90,5/90,5%; incl. re-lubricating device; cooling IC411; sound pressure level 61/74 dB; terminal box position on the right; terminal number 9; the possibility of rotation of the terminal box yes; Paint RAL5010
Switchable for constant or square torque.
45,0/65,0 kW; S1; 990/1480 min-1; 400V Δ/YY 50 Hz 3AC; 80,0/110 A; 434/419 Nm
attracting current 8,5/6,7 x In; starting torque 2,8/1,4xMn; tilting moment 2,6/1,9xMn
Efficiency 90,6/91,8%
Power values Basic (constant torque)
22,0/65,0 kW; S1; 983/1480 1/min; 380-420VY/Y 50 Hz 3AC; 39&108A; 214/419 Nm
attracting current 5,5/6,6 x In; starting torque 1,9/1,8 x Mn; Tilting moment 2,1/2,5 x Mn
Efficiency 88,3/93,6%
Power values fan design (square torque)
IEC 60034-1 design; Sound limit value IEC 60034-9
shaft Ø75 x 140 mm; heat class 155(F); incl. 3x PTC temperature sensors
Housing material up to frame size 112 aluminum, from frame size 132 grey cast iron
Rated power at coolant temperature -20...40° C and up to 1000 m above NN
Camp AS: NU317.C3; Camp BS: 6317.C3; Moment of inertia 0,47 kgm2
half-wedge weighting species; vibration stage "A"; Insulation class F
sound pressure level 60/69 dB; terminal box position on the right; Number of terminals 9
Paint RAL5010
- Foot mounting: Non-removable feet.