KEMMERICH ELEKTROMOTOREN
2,50/4,20 kW; S1; 710/1410 1/min; 400V ∆/YY 50 Hz 3AC; 3,2/3,7 A; 33,6/28,5 Nm
Power values correspond to basic design (constant torque)
attracting current 4,0/5,1 x In; starting torque 1,9/1,5 x Mn; tilting moment 2,5/2,2 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø38 x 80 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6308.ZZ.C3; Camp BS: 6308.ZZ.C3; moment of inertia 0,0319 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010; Efficiency at 2/4 load 73.2%/83.8% Efficiency at 3/4 load 77.0%/83.6% Efficiency at nominal load 77.5%/81.6%
4,7/5,70 kW; S1; 1445/2895 1/min; 400V ∆/YY 50 Hz 3AC; 9,3/11,5 A; 33,6/28,5 Nm
Power values correspond to basic design (constant torque)
attracting current 5,6/6,1 x In; starting torque 1,6/1,7 x Mn; tilting moment 2,3/2,4 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø38 x 80 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Ged material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6308.ZZ.C3; Camp BS: 6308.ZZ.C3; moment of inertia 0,029 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010
3,20/5,40 kW; S1; 710/1415 1/min; 400V ∆/YY 50 Hz 3AC; 8,7/10,4 A; 43,0/36,5 Nm
Power values correspond to basic design (constant torque)
attracting current 4,7/5,4 x In; starting torque 1,9/1,7 x Mn; tilting moment 2,6/2,3 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø38 x 80 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6308.ZZ.C3; Camp BS: 6308.ZZ.C3; moment of inertia 0,0399 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010; Efficiency at 2/4 load 74,8%/84,6% Efficiency at 3/4 load 78,2%/84,4% Efficiency at rated load 78,6%/82,4% Sound pressure level 56/64 dB
1,80/4,00 kW; S1; 470/940 1/min; 400V ∆/YY 50 Hz 3AC; 7,4/8,5 A; 36,57/40,64 Nm
Power values correspond to basic design (constant torque)
attracting current 3,3/4,9 x In; starting torque 1,8/1,4 x Mn; tilting moment 2,3/2,1 x Mn; IEC 60034-1 design; sound limit value according to IEC 60034-9; shaft Ø38 x 80 mm; heat class 155(F); in the case of B3 design, feet screwed to frame size132; Housing material up to frame size 112 aluminium, from frame size 132 grey cast iron; Rated power at coolant temperature -20...40° C and up to 1000 m above NN: Camp AS: 6308.ZZ.C3; Camp BS: 6308.ZZ.C3; moment of inertia 0,025 kgm2; half-wedge weighting species; vibration stage "A"; terminal box layer at the top; clamp/strand number 6; the possibility of rotation of the terminal box yes; Paint RAL5010; Efficiency at 2/4 load 59,0%/82,5% Efficiency at 3/4 load 65,8%/82,3% Efficiency at rated load 68,1%/80,0% Sound pressure level 73/72 dB