EDS3S AC
Single-phase input/output
The cost-effective and user-friendly single-phase frequency inverter was developed for use with single-phase induction motors with operating capacitor or shaded-pole motors.
|
|
|
|
|
Basic setting with 14 parameters. The default settings are suitable for most applications. Contactor connection for easy wiring. |
Precise digital control at the touch of a button. |
Choose between different modes for industry, pumps & fans to optimise the Optidrive E3 for your application. |
A built-in filter in every EDS3S saves costs and time during installation. Cat. C1 according to EN 61800-3:2004 |
- Engine power 0,75 kW
- Motor current 7,0 A
- Dimensions BxHxT 161x232x179 mm / 4 x M5
- Mains voltage, frequency 1-ph. 200V … 240V (+10%), 50/60Hz (±5%),
- Output voltage 0,0V up to maximum input voltage
- Overload capability 150% for 60s, 175% for 2,5s
- Output frequency 0... 120Hz (resolution 0,1Hz)
- Bluetooth, Modbus RTU- and CAN connectivity standard
- Protection type IP66
- Certification CE, cULus, RCM
Special boost phase
The special inverter for single-phase motors uses a revolutionary motor control strategy to ensure reliable and intelligent start of single-phase motors. In order to ensure reliable starting of single-phase motors, the converter firstly raises the motor voltage while maintaining a fixed starting frequency before reducing the frequency and voltage to the desired operating point.
No three-phase supply connection is necessary.
- Engine power 0,75 kW
- Motor current 7,0 A
- Dimensions BxHxT 83x173x123 mm / 4 x M5
- Mains voltage, frequency 1-ph. 200V … 240V (+10%), 50/60Hz (±5%),
- Output voltage 0,0V up to maximum input voltage
- Overload capability 150% for 60s, 175% for 2,5s
- Output frequency 0... 120Hz (resolution 0,1Hz)
- Bluetooth, Modbus RTU- and CAN connectivity standard
- Protection type IP20
- Certification CE, cULus, RCM
Special boost phase
The special inverter for single-phase motors uses a revolutionary motor control strategy to ensure reliable and intelligent start of single-phase motors. In order to ensure reliable starting of single-phase motors, the converter firstly raises the motor voltage while maintaining a fixed starting frequency before reducing the frequency and voltage to the desired operating point.
No three-phase supply connection is necessary.