Calpeda
Items 1 - 4 of 4
- Construction: self-priming liquid ring pump of block construction with a star-shaped impeller; CA 80, 90 and 91 with anti-lock intermediate ring
- Design: Cast iron version with pump housing and lantern from GJL 200
- Applications: For clean, non-abrasive and non-aggressive liquids without suspended solids; especially in the case of air or gas, unstable inlet, well removal and pressure increase
- Engine: 2-poleer single-phase induction motor with thermal protection
- Rated voltage: 230 V ±10 %, 50 Hz
- Engine rated power P2: 0,15 kW / 0,2 HP
- Maximum power consumption P1: 0,29 kW
- Rated current: 1,6 A at 230 V
- Rated speed: 2900 min-1
- Efficiency class: IE2
- Degree of protection: IP54
- Insulation class: F
- Operation mode: Continuous operation
- Flow according to characteristic curve: to 0,75 m3/h
- Maximum pump head according to the characteristic curve: 21,2 m
- Characteristic curve Q/H: 0 m3/h → 21,2 m; 0,12 m3/h → 20 m; 0,24 m3/h → 18 m; 0,38 m3/h → 15,5 m; 0,48 m3/h → 13 m; 0,6 m3/h → 10,5 m; 0,75 m3/h → 6,5 m3/h
- Media temperature: -10 to +90 °C
- Maximum ambient temperature: to 40 °C
- Suction height: to 9 m
- Maximum permissible working pressure: 6 bar
- Connections according to ISO 228: suction side DN1 G 1/2; Printing side DN2 G 1/2
- Dimensions: a 59 mm; A 100 mm; a1 18 mm; AA 22 mm; AB 122 mm; B 80 mm; BB 96 mm; fM 256 mm; H 63 mm; h1 103 mm; h2 25 mm; HA 8 mm; HD 158 mm; K 7 mm; l5 14 mm; w 103 mm
- Article weight: 5,9 kg
- Materials: pump housing and lantern GJL 200; Brass impeller CW617N; shaft AISI 430F; Slip ring seal carbon/ceramic/NBR
- Design according to: EN 60034-1; EN 60034-30-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; IP55; Special sliding ring seal; higher or lower media or ambient temperatures; Embodiment with bearing carrier
- Construction: self-priming liquid ring pump of block construction with a star-shaped impeller; CA 80, 90 and 91 with anti-lock intermediate ring
- Design: Cast iron version with pump housing and lantern from GJL 200
- Applications: For clean, non-abrasive and non-aggressive liquids without suspended solids; especially in the case of air or gas, unstable inlet, well removal and pressure increase
- Engine: 2-poleer three-phase induction motor
- Rated voltage: 230 V / 400 V ±10 %, 50 Hz
- Engine rated power P2: 0,15 kW / 0,2 HP
- Rated current: 1,7 A at 230 V / 1 A at 400 V
- Rated speed: 2900 min-1
- Efficiency class: IE2
- Degree of protection: IP54
- Insulation class: F
- Operation mode: Continuous operation
- Flow according to characteristic curve: to 0,75 m3/h
- Maximum pump head according to the characteristic curve: 21,2 m
- Characteristic curve Q/H: 0 m3/h → 21,2 m; 0,12 m3/h → 20 m; 0,24 m3/h → 18 m; 0,38 m3/h → 15,5 m; 0,48 m3/h → 13 m; 0,6 m3/h → 10,5 m; 0,75 m3/h → 6,5 m3/h
- Media temperature: -10 to +90 °C
- Maximum ambient temperature: to 40 °C
- Suction height: to 9 m
- Maximum permissible working pressure: 6 bar
- Connections according to ISO 228: suction side DN1 G 1/2; Printing side DN2 G 1/2
- Dimensions: a 59 mm; A 100 mm; a1 18 mm; AA 22 mm; AB 122 mm; B 80 mm; BB 96 mm; fM 256 mm; H 63 mm; h1 103 mm; h2 25 mm; HA 8 mm; HD 158 mm; K 7 mm; l5 14 mm; w 103 mm
- Article weight: 5,8 kg
- Materials: pump housing and lantern GJL 200; Brass impeller CW617N; shaft AISI 430F; Slip ring seal carbon/ceramic/NBR
- Design according to: EN 60034-1; EN 60034-30-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; IP55; Special sliding ring seal; higher or lower media or ambient temperatures; Embodiment with bearing carrier
- Construction: self-priming liquid ring pump of block construction with a star-shaped impeller; CA 80, 90 and 91 with anti-lock intermediate ring
- Design: Bronze version with pump housing and bronze lantern CC480K
- Applications: For clean, non-abrasive and non-aggressive liquids without suspended solids; especially in the case of air or gas, unstable inlet, well removal and pressure increase
- Engine: 2-poleer single-phase induction motor with thermal protection
- Rated voltage: 230 V ±10 %, 50 Hz
- Engine rated power P2: 0,15 kW / 0,2 HP
- Maximum power consumption P1: 0,29 kW
- Rated current: 1,6 A at 230 V
- Rated speed: 2900 min-1
- Efficiency class: IE2
- Degree of protection: IP54
- Insulation class: F
- Operation mode: Continuous operation
- Flow according to characteristic curve: to 0,75 m3/h
- Maximum pump head according to the characteristic curve: 21,2 m
- Characteristic curve Q/H: 0 m3/h → 21,2 m; 0,12 m3/h → 20 m; 0,24 m3/h → 18 m; 0,38 m3/h → 15,5 m; 0,48 m3/h → 13 m; 0,6 m3/h → 10,5 m; 0,75 m3/h → 6,5 m3/h
- Media temperature: -10 to +90 °C
- Maximum ambient temperature: to 40 °C
- Suction height: to 9 m
- Maximum permissible working pressure: 6 bar
- Connections according to ISO 228: suction side DN1 G 1/2; Printing side DN2 G 1/2
- Dimensions: a 59 mm; A 100 mm; a1 18 mm; AA 22 mm; AB 122 mm; B 80 mm; BB 96 mm; fM 256 mm; H 63 mm; h1 103 mm; h2 25 mm; HA 8 mm; HD 158 mm; K 7 mm; l5 14 mm; w 103 mm
- Article weight: 6,3 kg
- Materials: Pump housing and lantern bronze CC480K; Brass impeller CW617N; shaft AISI 316; Slip ring seal carbon/ceramic/NBR
- Design according to: EN 60034-1; EN 60034-30-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; IP55; Special sliding ring seal; higher or lower media or ambient temperatures; Embodiment with bearing carrier
- Construction: self-priming liquid ring pump of block construction with a star-shaped impeller; CA 80, 90 and 91 with anti-lock intermediate ring
- Design: Bronze version with pump housing and bronze lantern CC480K
- Applications: For clean, non-abrasive and non-aggressive liquids without suspended solids; especially in the case of air or gas, unstable inlet, well removal and pressure increase
- Engine: 2-poleer three-phase induction motor
- Rated voltage: 230 V / 400 V ±10 %, 50 Hz
- Engine rated power P2: 0,15 kW / 0,2 HP
- Rated current: 1,7 A at 230 V / 1 A at 400 V
- Rated speed: 2900 min-1
- Efficiency class: IE2
- Degree of protection: IP54
- Insulation class: F
- Operation mode: Continuous operation
- Flow according to characteristic curve: to 0,75 m3/h
- Maximum pump head according to the characteristic curve: 21,2 m
- Characteristic curve Q/H: 0 m3/h → 21,2 m; 0,12 m3/h → 20 m; 0,24 m3/h → 18 m; 0,38 m3/h → 15,5 m; 0,48 m3/h → 13 m; 0,6 m3/h → 10,5 m; 0,75 m3/h → 6,5 m3/h
- Media temperature: -10 to +90 °C
- Maximum ambient temperature: to 40 °C
- Suction height: to 9 m
- Maximum permissible working pressure: 6 bar
- Connections according to ISO 228: suction side DN1 G 1/2; Printing side DN2 G 1/2
- Dimensions: a 59 mm; A 100 mm; a1 18 mm; AA 22 mm; AB 122 mm; B 80 mm; BB 96 mm; fM 256 mm; H 63 mm; h1 103 mm; h2 25 mm; HA 8 mm; HD 158 mm; K 7 mm; l5 14 mm; w 103 mm
- Article weight: 6,2 kg
- Materials: Pump housing and lantern bronze CC480K; Brass impeller CW617N; shaft AISI 316; Slip ring seal carbon/ceramic/NBR
- Design according to: EN 60034-1; EN 60034-30-1; EN 60335-1; EN 60335-2-41
- Options on request: other voltages; 60 Hz; IP55; Special sliding ring seal; higher or lower media or ambient temperatures; Embodiment with bearing carrier
Items 1 - 4 of 4